Electrical Testing And Supplies - Tan-Delta Testing Of Transformer Reacto, Lt Acb Breaker Test Servicing, Ht Vcb Breaker Testing Servicing, Buchholz Relay Test, Thermal Omicron B2hv Relay Test, Partial Discharge Test Of Transformer, Third Harmonic Testing Of La Lightning, Insulation Mat Test, Testing Of Mccb Rccb, Insulation Resistance Test Of Motors, Pi Polarization Index Test Of Motors, Transformer Oil Test As Per Is 1866, Voltameter Ammeter Calibration, Calibration Of Energy Meters, Vcb Bottles Inspection Test For Healthi, Vlf Very Low Frequency Testing Of 100, Thermography Of Panels, Vfd U.P.S Inver, Electromechanical Relays Testing, Numerical Relays Testing, Transformer Oil Filtration, Electrical Safety Audit Esa For, Pi Of 100 Power Cables, Ir Of 100 Power Cables, Current Transformer Testing, Wti Winding Temperature Indicator Cali, Oti Oil Temperature Indicator Calibrat, Liasoning Charges-Cea, Supply Of Megger Tester, Led 300 Watts For High Mast Tower, Led Lights 90 W, Earthpit Testing, Lt Hand Gloves, Ht Hand Gloves, Sply Flp Switches, 4C 1.5Sqmm Armored Cable, Vcb Battery, Capacitor 25Kvar, Capacitor 20 Kvar, Capacitor 10 Kvar, Ampere Meters For Panels, Hammer Driill Machine, Earthstrips 50 6, Earthstrips 25 6, 4 Sqmm Earthing Cable, Earth Tester
Custom Bid For Services - Complete Repairing And Overhauling Of 01 No Existing Outdoor Type Installed 1000 Amp Acb Panel Lt440v Of B Type Single At Urjanagar Colony Of Rajmahal Area
Custom Bid For Services - Contract For Servicing Of Schneider Make Lt Panels And Acbs Of Various Rating At Site During Bpcl Kochi Refinery Sep24 Shutdown For A Period Of One Year
Procurement Of Lt Switchgear Spares -Xfmr, Curr, 200/1A, 15Va, Cl-1/5P20, Xfmr, Curr, 150/1A, 0.415/0.66Kv, 7.5Va, Cl-1, Xfmr, Curr, Metering, Wpl, Resin Cast, 100/1A, Xfmr, Curr, 75/1A, 7.5Va, Cl-1, L&T:Fn315/400/630/800 Hndl Asy-B:Sk91279, Mcc:L&T:Fn-200/250 Handle Assy.-B, Mcc:L&T:Fn-32/63 Handle Assy.- Ce, L&T:Handle Assy-A For Fn125:Sk912580000, Xfmr, Pot, 415/110V, 50Va, Cl-1, Xfmr, Pot, 415Vr3/110Vr3, 50Va, Cl-1, Xfmr, Curr, Ring, Resin Cast, 3000/1A, Cl-Ps, Xfmr, Curr, 3000/1A, 0.415/0.66Kv, 7.5Va, Xfmr, Curr, Resin Cast, 1000/1A, Cl-Ps, Xfmr, Curr, 1000/1A, 0.415/0.66Kv, 7.5Va, Xfmr, Curr, 630/1A, 0.415/0.66Kv, 7.5Va, Power Contctr.: 3P, 110Vac, L&T-Mnx18, Pwr.Contctr.: 3P, 110Vac, 110Vac, L&T-Mnx32, Powr Contr:3P415vac:110Vac:L&T:Mnx70, Power Contctr.: 3P, 110Vac, L&T-Mnx110, Power Contactor Mnx225, 415 Volts, Ac3, , Contactor, Power, 415Vac, 400A, 3P, L&T, Coil, Cs94142, L&T, Contactor, Mnx265, Contact Block 1No+1Nc, 2Nd Left-#Cs94207, Contact Block 1No+1Nc-Second Right-Cs942, Side Add On Lhs, 1No+1Nc For Mnx9-40, Cs94, Side Add On Rhs, 1No+1Nc For Mnx9-40, Cs94, Switch Disconnector Fuse Tpn Fn125 L&T, Switch Disconnector Fuse Tpn, Fn250 L&T, Switch Disconnector Fuse Tpn Fn400 L&T, S/W Rotry Waf:4 Way:440V Ac, 32A:Salzer, Rotry Waf S/W On/Off 240Vac 25A Salzer, O/L Mn12l 66-110A, L&T Make, Selectr.Switch: 4-Posn, 16A, 220Vdc;Salzer, S/W Sel:On / Off:16A 220Vdc:Salzer, S/W Sel:2:Pos:16A, 240Vac:Salzer, S/W Rotry Waf:4 Way:660V Dc, 25A:Salzer, Racking Nut For L&T Module, O/L Relay Type Mn2 L&T 0.9-1.5 A, Relay, Thermal O/L, 0.6-1A, Mn2, L&T, Thermal Bi-Metal O/L Relay:Mn2, 0.3-0.5A, Bimetal O/L Relay Type Mn2 Range4.5-7.5A, Thermal Overload Relay:A1.4-2.8, 6-10Amp Over Load Relay L&T Make, Rely Th O/L:14-25 A:L&T Make Mn2, O/L Relay L&T Mn2; 9-15A Singleeph.Prot., Overload Relay Range : 3-5A, Type:Mn2, Thermalo/Lrlymn12, 135A -225A, Ss94138, L&T, Ct Opr Bim;90-150A;Mn12;L&T-Ss94138oomo, Pulling Handle, Sk 91185, L&T, Right Micro Switch For L&T Make Acb, Left Micro Switch For L&T Acb, Microswitch Test/Isolate Position Right, Microswitch Test/Isolate Position Left, Charging Motor, Sl00347oooo, L&T, Closing Coil 220V Dc For L&T Make Bkr., Shunt Release Ea 220V Dc 501-30-98266, Frcd For L&T Make Cn-Cs 4000A Edo, Resistor Kit 220 V D.C.For L&T Acb, Racking Interlock For L&T Breaker, Bezel For C-Pwr.Brkr-1250A, #Sl916020000, Elect Position Indication For L&T Acb, Panel Door Ingress Seal, D/Out Acb, Stablsng Resstr Varabl 0-2000Ohm200w 1A, Lock A Type For L&T Acb Rackout Locking, Cam Lock For Doors Of L&T Switch Gear, Door Interlock For L&T Make Acb, Lt Air Circut Breaker Key Lock T-Aklaf12, Reset Cord For Over Load Relay, Lt Swtch Gr:Reset Cord 1Metre Long, Kit Mount Mn2 Relay Onn Ml0/1/1.5 , 6 Way Sic Block Cat No. Sl92701; L&T, Sec Isoltng Conts+Tbrak-F/M L&T Make, Sec Isoltng Conts+Tserv-F/M L&T Make, Sec Iso Cont Serv Sa92567 For Lt S/G, L&T-Sec Iso Contact Male - Sa92565, Racking Handle Of L&T Modules, Racking Handle For L&T Acb, Aux Cont Kit Typ Fn315 C No.Sk91330 L&T, Aux Cont Kit Typ Fn200/250 C No.Sk91329, Aux Cont Kit Fn100/125/160C No.Sk91328, Auxiliary Contact Kit For Fn63, Aux Contr:L&T:Add On Block-Cs94112, Aux Contr: L&T-Add On Block, Cat-Cs94113, Aux Contr: L&T-Add On Block-Cs94114, Aux Contr: L&T-Add On Block-Cs94120, F, Aux Contactor: L&T-Add On Block-Cs94121, Contactor, Auxiliary, 110Vdc, 6A, 2No+2Nc, Frcd, For, 1250 /2500/4000A, Acb, Spare Kit L&T Make For Mnx110 Contactor, Spare Kit Without Coil Mnx225 Cat-94157, Spare Kit Without Coil Mnx400 Cat-94161, Powr Contr:2P 22Vdc:Cv 220Vdc:200A, Spring Charging Assy, Sl90686oooo, L&T, Front Facia- For Electrical Acb, Sl93202, 220 V Dc Spring Charge L/Switch Assy, L&T
Supply At Site, Testing Of Lt In Door Panel, Made Of Crca Sheet Steel Of 2 Mm Thickness And Over All Dimension, Hxwxd 2300X2000x900 Mm . Feeder Pillar Will Have 800A Tpn Copper Bus Bar Of 99.9% Pu Rity Electrolytic Grade Having 50X10 Sq.Mm Cross Section For Phase And 50 X5 Sq.Mm For Neutral Bus Bar .P Hase Phase Gap Min. 75Mm, Phase To Neutral Min. 50Mm& Phase To Body Will Be 50Mm.All Bus Bar Will Be Colour Coded & To Be Fitted On Dmc Insulator..It Will Have Ms Channel 75X40x6mm Of Size. Panel Comprising Of Two N Os. Acb Of Rating 800A, Breaking Capacity65ka 4P, 415V Mdo Operational Voltage690v With All Necessary Relate D Units Including Digital Voltmeter, Ammeter, Energy Meter, Ct Etc. As Incoming, One No. 630Amp, 4 Pole415v On Load Change Over Switch And 2 Nos. 630A 4 Pole 65Ka 415V Mccbs- 2 Nos With Necessary Accessories, 400Amp 4 Pole 65Ka 415V Mccbs- 2 Nos. With Necessary Accessories, 250Amp 4 Pole 55Ka 415V Mccbs- 2 With Necessary Accessories As Outgoing With Volt Meter, Ammeter, Indication Lamp Etc. As Per Is Specification & Cee/Grcs Specificationifany A With Latest Amendment If Any . All Mccbs Are With Adjustable Thermal An D Fixed Magnetic Setting And Necessary Protection Arrangement As Required To Complete The Work In All Respect. All Accessories Are To Be Provided To Complete The Work In All Respect. As Per Direction Of Elect.G Supervisor Rai Lway Site Incharge. The Item Should Be As Per Is Specification & Cee/Ser/Grc Office Specificationif Any With L Atest Amendment. The Item Should Follow The Pcee/Ser/Grc Office Specification Vide No-Cee/P/56/301/Maint Enance Dt 12.12.2022 & Latest If Any. Each Panel Should Consist Of Energy Meter Digital Whole Current Meter Positively. Make:-Panel Confirming To Is Specificationif Any With Cpri&Erda Test Certification With Approval Of Dee/G/Adra. Equipment Make- L&T/Havell/Abb/Siemens With Approval Of Dee/G/Adra.Erection Cost Include S The Cost Of Dismantling Of Old One If Any & The Cost Of Installation Of New One As Per Site Requirment As Advise D By Railway Site Incharge With All Necessary Accessories To Complete The Work In All Respect. Warranty Perio D: 30 Months After The Date Of Delivery