Supply of Ground Connection And Insulating Materials For Universal Type Point Machine 110 V Dc Compl Ete.Rdso/S-3361-62. Detail Of Various Parts Of Ground Connection As Per Drg No. Rdso/S 3361-62: 1 As Per S Pecification: Rdso/S 3369 Lock Rod Near End: 1 No. As Per Drg.No. Rdso/S-3361-62 Detail Of Each Item Is I N The Annex Warranty Period: 30 Months After The Date Of Delivery
Supply of Ground Connection Of 220Mm Point Machine As Per Rdso Drawing Attached. Lock Rod 02, Dete Ction Rod 02, P. Bracket 02 01 Set Warranty Period: 30 Months After The Date Of Delivery
Supply Of Ground Connection Insulation Set Made Of Nylon 66 As Per Specification No. Irs-S-40/84 Or Latest. Consisting One Set As Follows A. Insulation Side Plate Lh To Drg-S 3266 01No. B. Insulation Side Plate Rh To Drg-S 3265 01No.C. Insulation Brush To Drg-S 23199 4Nosd. Insulation Washer To Drg-S8640 06Nos.E.Insulation Plate To Drg No-S 8804 01No.F. Insulation Bush To Drg No-S 8813 2Nos., Make/Brand - Titania Or Similar Warrant Y Period: 30 Months After The Date Of Delivery
Supply of Insulation Sets For Ground Connection, Made Of Nylon-66 For 220Mm Throw Thick Web Switch Poin T Machine, As Per Specification No. Irs.S.40/84 Or Latest. One Set Consisting Material Of :- 1 Insulating Washer Drg. No.-S-8640 12 Nos. 2 Insulating Washer Drg. No.- S-8640/1 04 Nos. 3 Insulating Washer Drg. No.-S- 8640/2 02 Nos. 4 Insulating Bush D Rg . No.-S-23199 10 Nos .5 Insulating Bu Sh D Rg . No.-S-3463 01N O . 6 Insulating Bush Drg. No.-S-22179 02 Nos. 7 Insulating Bush Drg. No.-S-8912 02 Nos. 8 Insulating Plate D Rg. No.-S-3404 02 Nos. 9 Insulating Bush Drg. No.-S-8813 04 Nos. 10 Insulating Plate Rh Drg. No. S-3592- 1No. 11Insulating Plate Lh Drg. No. S-3593-1 No. Warranty Period: 30 Months After The Date Of Delivery
Left Over Electrification Work Of 07 Nos- Quarters Of Bhojipura, 11 Kv/415 Volt Sub-Station And Allied Work At Lalkuan, Second Platform Of Harsinghpur Goba, 150M Long Extended Platform Of Kasganj Station And Under Ground Cabling For High Mast Of Pilibhit Goods Siding In Connection With Kanpur-Kasganj-Mathura & Kasganj-Bareilly-Lalkuan Incl. Material Modification For Extension From Bareilly To Lalkaun And Mandhana-Brahmavart552.9 Km And Philibhit-Shahjahenpur Gauge Conversion Projects, Respectively
S&T Work In Connection With Construction Of New Fob Near Tisco Ground, Badampahar Station.
Electrical Work In Connection With Up Gradation Of Adsa Ground Sabarmati.
Supply of Insulation Set For Ground Connection Of High Thrust Point Machine With 220Mm Throw And Clamp Typ E Locking As Per Irs S 24-2002.Ground Connection Specification Is Rdso/S 3454. Oem/Authorised Dealers Guar Antee Certificate To Be Submitted At The Time Of Supply Accepted Offer : Insulation Sets For Ground Connection, Ma De Of Nylon66 For 220Mm Throw Point Machine As Per Irs.S.40/84 Or Latest. One Set Consisting Material Of: A Ins Ulating Washer Drg. No.-S-8640 12Nos. B Insulating Washer Drg. No.:-S-8640/1 04Nos. C Insulating Washer Drg. No.:-S8640/2 02Nos, Dinsulating Bush Drg. No.:- S 23199 10Nos, E Insulating Bush Drg. No.:-S 3463 01 Nos. F Insulating Bush Drg. No.:-S 22179 02Nos G Insulating Bush Drg. No.:-S-8912 02Nos, H Insulating Plat E Drg. No.:-S 3404 02Nos, I Insulating Bush Drg. No.:-S 8813 04Nos, J Insulating Plate Rh Drg. No.:-S 3265 01No, K. Insulating Plate Lh Drg. No.:-S 3266 01No All Above Set Applicable And Fixed To Ground Connection Spe Cification Is Rdso/S 3454. Make: Sht.Sample Of One Set To Be Sent First For Approval To Co Nsignee. Note : The Material Should Be Only Nylon-66 If Not Found Nylon-66 Will Be Rejected. The Material Nyl On-66 Will Be Checked In A Recognized Lab Warranty Period: 12 Months After The Date Of Delivery
Electrical Work In Connection With Manning Of Lc Gates Between Der Station And Ntpc/Der. Electrical Work In Connection With Tundla-Ghaziabad: Replacement Of 12 Nos Type-Ii Old Dilapidated Qtrs By New Quarters In Tundla- Ghaziabad Section. Electrical Works In Connection With Prayagraj Division -Construction Of New Crew Running Room At Prayagraj. Electrical Work In Connection With Renovation Of Swimming Pool, Outside Area And Dismantling Of School In Coral Club At Prayagraj. Electrical Work In Connection With Provision Of New Toilet Block With Other Wellness Facilities At Dsa Ground Prayagraj. Electrical Work In Connection With Construction Of New Station Building At Rooma Station Pryj-Cnb Section. Electrical Work In Connection With Construction Of Office And Store For Sse Of S&T Department At Aligarh Station Of Prayagraj Division. Electrical Work In Connection With Provision Of Blc Monitoring Centre At Etw Station.
Supply Of Electric Point Machine Non-Trailable Type Confirming To Rdso Specification No.Irs:S-24/2 002 Amendment No.1 Or Latest With Following Further Information: A 220Mm Throw With Interlocking For Operation Of Point In Railway Yard As Per Rdso Drg.No.S-11000. B Type Of The Ground Connection With Nylon Insulation Confi Rming To Rdso Drg No.S-3454 And Clamp Point Lock Confirming To Rdso Drg No.3395 For 60Kg. Thick Web Swit Ch. C Ac Immunity Level Of Motor For Electric Point Machine Should Be Of 400V R.M.S. 50Hz. The External Colour Of The Electric Motor Shall Be Painted With Red Colour Warranty Period: 30 Months After The Date Of Delivery
Providing, Supplying, Lowering, Laying, Jointing Rcc Np3 Pipe For Sewer Collecting System, Construction Of House Connection Chamber, Property Connections, Di-K7 Pipe For Rising Main, Construction Of Pumping Station With Screen Chamber, Supplying And Installation Of Pumping Machinery, Renovation Of Pumping Station, O And M Of Under Ground Drainage For Thasra Town Under Sjmmsvy Taluka:- Thasra,
Supply of 415 Volts Ac Pre-Cooling Cum 110V. Dc Battery Charging Box Shall Be Fabricated With Ms Sheet 3Mm Thick And Ms Angle Of Size 40X40x5 Mm. The Box Shall Be Out Door Type, Floor Mounted Weather, Dus T & Vermin Proof With Degree Of Protection Ip54. It Shall Be Divided Into Two Compartments Of Equal Size Whi Ch Shall Have Independently Hinged Doors For Both The Compartments Lockable And Double Earthing Terminal Proper Canopy Shall Be Provided On The Top To Prevent Rain Water Entering Inside The Box. Separate Detach Able Plate 3Mm Thick Ms Sheet For Both Compartment Shall Be Provided 100 Mm Dia. Hole With Groomet For Incoming And Outgoing Cable. Incoming & Out Going Cable Shall Be Connected With The Bus-Bar From Bottom Side. The Box Shall Be Finished With Powder Coating Of Approved Colour Thickness Not Less Than 40 Microns. A1st Compartment Shall Be Suitable For Accommodating 1 No. 100 A. 4 Pole Mccb Fixed Type Thermal Mag Netic Release 35 Ka Breaking Capacity And Conforming To Is:13947/Part-2 & Iec: 60947/2, One 63A 5Pin 3P+ N+E415 V. Panel Mounted Socket With Spring Locked Cover & One 63A. 5 Pin 3P+N+E 415 V. Plug Conformi Ng To Iec 309/1&2, One No.16A.3Pin2p+E 250 V. Panel Mounted Socket With Spring Locked Cover & 1No. 16A 3 Pin2p+E 250 V. Plug Conforming To Iec 309/1&2 And 200A. Aluminium Bus-Bar For Phases & Neutral Shoul D Be Fixed On Fiber Sheet With Pvc Sleeve Colour Coded. 2Nd - Compartment Shall Be Suitable For Accommo Dating 1 No. 32 A. Dc Series Mcb Dp Suitable For 130 V Dc Supply, One No. Panel Mounted 32A 3 Pin 2P+E Socket With Spring Locked Cover A One No. 32A 3 Pin 2P+E Plug Conforming To Iec 309/1&2 And 200A. Alum Inium Bus-Bar For Two Positive & One Negative Should Be Fixed On Fiber Sheet With Pvc Sleeve Colour Code D. B Mccb & Mcb Should Be Operated Without Opening The Front Cover Inter- Connection With Suitable Siz E Pvc Insulated Copper Conductor Cable Conforming To Is:694/1990 From Bus Bar To Mccb/Mcb To Socket. 3 Core & 4 Core Pvc Insu- Lated And Pvc Sheathed Copper Conductor Flexible Cable Up To 110 V-Shall Be Co Nfirmed To Is:694 With Plugs. Proper Visible Indication Plate Fluorescent Screen Printed On The Front Of Both C Ompartments Shall Be Provided For 415V. Ac Pre-Cooling Box And 110V Dc Battery Charging Box As Approved By Railway. Cthe Box Shall Be Grouted In Ground With Cement Morter Mixing 1:2:4 With Muffing As Per Rail Way Drawing. Note:- It Should Be Ensured: 1 All Cable Connections To Be Db S J.Box Panel Etc. Should Be M Ade Through Proper Size Of Cable Glands/End Fittings No Space Should Be Left Open To Avoid Entry Of Insect S/Lizards Etc. If Necessary, Blanking Plate Should Be Provided In Dbj. 2 Flexible/Rigid Conduits Wherever Provi Ded Should Be With Suitable End Fittings/Clamps Conduit Should Be Secured On Surface Through Suitable Clamps At Regular Interval As Per Is Spec. 3 Sitc As Per Attached Drawing. Warranty Period: 30 Months After The Date O F Delivery