Supply of 1019 Ballistic Computer Fully Formed To Drg 7136.41. 00.000 Q3 Control Panel For Ballistic Computer To Drg 7136.34. 00.000 Q3 Alg Control Panel To Drg 7136.10. 05.000 Q3 Indication Unit To Drg 7136.60. 00.200 Q3 Mode Switch To Drg 7136.60. 00.100 Q3
Supply of Led Indication Panel To Cgl Material Code - 786241114 Warranty Period: 30 Months After The Da Te Of Delivery
Supply And Commissioning Of Rmpu, Control Panel And Microprocessor Control Unit For Use I N Self-Propelled Inspection Car Spic And Shall Meet The Following Requirements. 1.Lhb Type Roof Mounte D Ac Package Unit Type-Ii Suitable For R-407C Refrigerant Shall Be As Per Rdso Specification No. Rd So/Pe/Spec/Ac/0061-2005 Rev-1 And Micro-Processor Controller Unit Shall Be As Per Rdso Specification No. Rdso/Pe/ Spec/Ac/0139-2009 Rev.1, Type-I. 2.Ac Control Panel For Rmpu Shall Have Switch Gears Like Cont Actors, Mpcb, Mcb, Relays, Ovrs, Indication Lamp Etc., As Per Rcf Drg: No. Sked 625, Rdso/Pe/ Sk/Ac/01 90-2015 Rev.0, Rdso/Pe/ Sk/Ac/0186-2015 Rev.0 & Rdso/Pe/ Sk/Ac/0158- 2011 Rev.0, To The Above Specification. The Cage Clamp Type Terminal Connectors Required For Input And Output Power And Control Cables Of Rmpu Shall Be Provided In The Control Panel Acceptable Makes Of Terminal Blocks Are Wago, Phoenix, Wei Dmuller, Connectwell & Elmex. 3.The Overall Dimension Of The Control Panel Shall Not Exceed 550 Mm X 800Mm X 200Mm Wxhxd. 4.The Micro-Processor Controller And Switch Panel As Per Drg.No. Rdso/Pe/Sk/A C/0125 Rev.1 2009 Shall Be Integrated In To Ac Control Panel. 5.The Control Panel Shall Be Supplied Along With Po Wer And Control Cables For Connecting With Rmpu As Per Rcf Specn-Edts-252, Rev-I, Annexure-B Harness No S-31, 31A31b, 31C, 31D&31E To A Length Of 10Mtrs For Operation Of Rmpu. 6.The Overall Dimensional Drawing And Bom For The Control Panel Shall Be Submitted For Approval Before Offering For Prototype Inspection. Note: 1 Earth Ing Lug Arrangement On Rmpu Shall Be As Per Drg No.Icf/ Sk3-7-6-035 Ii Packing Instruction: Roof Mounted Ac Package Unit Packed With Corrugated Paper With Water Proof Jute Fabric And Supplied And St Acked In Pallets At Icf. The Pallets Should Be Painted And Have Firms Logo For Identification. The Firm Will Collect E Mpty Pallets Only After Ac Package Unit Is Loaded In The Coach. Warranty Period: 30 Months After The Date Of Del Ivery
Supply Of Spares For Abc Electricals Pvt Ltd Make Different Capacities Drill Panels From Oem Transformer Coil Only-B, Part No. Sdp-A-0001-1C, Electromagnetic Earth Leakage System, Part No. Sdpa-0001-2, Pilot Relay, Part No. Sdp-A-0001-2B, Test Relay, Part No. Sdp-A-0001-2C, Bridge Rectifier Unit, Part No. Sdp-A-0001-2D, Neutral Resistor, Part No. Sdpa-0001-7, Test Reset Microswitch, Part No. Sdp-A0001-8, Leakage Indication Lamp, Part No. Sdp-A-0001-9, Leakage Indication Lamp Holder, Part No. Sdp-A-0001- 10, 30A Restrained Plug And Socket Complete, Part No. Sdp-A-0002, Isolator Switch 40A, Part No. Sdp-A0005-1, Through Going Terminal Box Complete, Part No. Sdp-A-0009-B
Design, Fabrication, Supply And Testing And Installation Of 1 Remote Panel As Per Given Drawing 2 Column Assembly 1.5 Mtr Length Of 35Hp Vertical Turbine Pump 3 Removal Of Old Indication Lamps, Modification Of Ckt And Installation Of Ind Lamps
Supply Of Epoxy Items - Trip Indication Panel Base Plate, Resistor & Capacitor Mounting Plate, Relay Panel, Distance Piece, Cable Support Bar, Duct Insu. Cover Plate Lh/Rh, Duct Insu. Cover Plate Top, Etc
Supply Of Pre Wired Polycarbonate Control Panel As Per Fi/40854 With All Safety Accessories, Indicators&Controls, Suitable For 3 Nossmps Units Supplied By Railway Used For The 16W Led Pit/Catwalk Lights.Shall Have Ingress Protection Ip 65 As Per Iec 600529. Shall Be Provided With Polymide Locking Screws And Polymide Hing Es.Shall Be Suitable For Operation For Ambient Temprature Up To 85 Degree Celsius. Shall Beable To Resist Up To 1 Kv Insulation.Enclosure Shall Be Halogen And Silicon Free, Shall Be Fire Retardant Self Extinguishing As Per Vded471/Ul94.Enclosure Shal L Be Uv Resis Tant As Per Ul746 . Supplier Shall Submit Drawing Data Sheet. Enclosure Make:Grasp/Siemens/Hensel/Abb Input:230V Ac, 2Pole 20A Mcb, 30A Terminal Connectors, Output:24Vdc 10Amps Each, 4Sqmm Terminal Block /Connectiors Accessories:2 Pole 20 Amp Mcb, On/Off Rotary Switch Foron/Off3nos Of Smps Units, 3Nos Of Green Indicatio N24v Dc Smps On/Off, 1 No Red Indication For Mains On/Off. Model No:Osse/Cpu/Pc/2023. Size:450X300x210+/-5Mm Note: Smpss Will Be Supplied By Railway Only. Warranty Period: 12 Months After The Date Of Delivery
Supply of Lt Panel Board With Copper Busbar Of 400 A, 3 Phase & Neutral 416V Floor Mounted Type Comprisin G Of 3 Nos X 400 Amp 4- Pole Mccb Adjustable Thermal And Adjustable Magnetic Setting Type & 2 No X 400 A Mp, 4 Pole 416 Volt Changeover Switch As Incoming And 2 Nos. X 250 Amp, 4 Pole Mccb Adjustable Thermal And Adjustable Magnetic Setting Type & 4 Nos. X 100 Amp 4 Pole Mccb & 10 Nos. X 63 Amp 4 Pole Mccb As Outgoing Including Hrc Type Back Up Fuses With Each Mccbs As Per Their Rating Electronic Frequency Meter, Ef & Oc Relay, Digital Voltmeter & Ammeter Etc With Selector Switch, Led Indication Lamp On Each Incoming & Outgoi Ng Circuit Fitted In Suitable Size Duly Pointed Crca Steel Box Powder Coated Enclosure. Warranty Period: 30 M Onths After The Date Of Delivery
Supply of 415 Volts Ac Pre-Cooling Cum 110V. Dc Battery Charging Box Shall Be Fabricated With Ms Sheet 3Mm Thick And Ms Angle Of Size 40X40x5 Mm. The Box Shall Be Out Door Type, Floor Mounted Weather, Dus T & Vermin Proof With Degree Of Protection Ip54. It Shall Be Divided Into Two Compartments Of Equal Size Whi Ch Shall Have Independently Hinged Doors For Both The Compartments Lockable And Double Earthing Terminal Proper Canopy Shall Be Provided On The Top To Prevent Rain Water Entering Inside The Box. Separate Detach Able Plate 3Mm Thick Ms Sheet For Both Compartment Shall Be Provided 100 Mm Dia. Hole With Groomet For Incoming And Outgoing Cable. Incoming & Out Going Cable Shall Be Connected With The Bus-Bar From Bottom Side. The Box Shall Be Finished With Powder Coating Of Approved Colour Thickness Not Less Than 40 Microns. A1st Compartment Shall Be Suitable For Accommodating 1 No. 100 A. 4 Pole Mccb Fixed Type Thermal Mag Netic Release 35 Ka Breaking Capacity And Conforming To Is:13947/Part-2 & Iec: 60947/2, One 63A 5Pin 3P+ N+E415 V. Panel Mounted Socket With Spring Locked Cover & One 63A. 5 Pin 3P+N+E 415 V. Plug Conformi Ng To Iec 309/1&2, One No.16A.3Pin2p+E 250 V. Panel Mounted Socket With Spring Locked Cover & 1No. 16A 3 Pin2p+E 250 V. Plug Conforming To Iec 309/1&2 And 200A. Aluminium Bus-Bar For Phases & Neutral Shoul D Be Fixed On Fiber Sheet With Pvc Sleeve Colour Coded. 2Nd - Compartment Shall Be Suitable For Accommo Dating 1 No. 32 A. Dc Series Mcb Dp Suitable For 130 V Dc Supply, One No. Panel Mounted 32A 3 Pin 2P+E Socket With Spring Locked Cover A One No. 32A 3 Pin 2P+E Plug Conforming To Iec 309/1&2 And 200A. Alum Inium Bus-Bar For Two Positive & One Negative Should Be Fixed On Fiber Sheet With Pvc Sleeve Colour Code D. B Mccb & Mcb Should Be Operated Without Opening The Front Cover Inter- Connection With Suitable Siz E Pvc Insulated Copper Conductor Cable Conforming To Is:694/1990 From Bus Bar To Mccb/Mcb To Socket. 3 Core & 4 Core Pvc Insu- Lated And Pvc Sheathed Copper Conductor Flexible Cable Up To 110 V-Shall Be Co Nfirmed To Is:694 With Plugs. Proper Visible Indication Plate Fluorescent Screen Printed On The Front Of Both C Ompartments Shall Be Provided For 415V. Ac Pre-Cooling Box And 110V Dc Battery Charging Box As Approved By Railway. Cthe Box Shall Be Grouted In Ground With Cement Morter Mixing 1:2:4 With Muffing As Per Rail Way Drawing. Note:- It Should Be Ensured: 1 All Cable Connections To Be Db S J.Box Panel Etc. Should Be M Ade Through Proper Size Of Cable Glands/End Fittings No Space Should Be Left Open To Avoid Entry Of Insect S/Lizards Etc. If Necessary, Blanking Plate Should Be Provided In Dbj. 2 Flexible/Rigid Conduits Wherever Provi Ded Should Be With Suitable End Fittings/Clamps Conduit Should Be Secured On Surface Through Suitable Clamps At Regular Interval As Per Is Spec. 3 Sitc As Per Attached Drawing. Warranty Period: 30 Months After The Date O F Delivery
Procurement Of 110 V Dc Green Colour Low Intensity Led Lamps With Holder Assembly And Cove R To Be Used As Hlc-1 On Command And Hlc-2 On Command In Complete Panel D With Panel Plate Drawing No. Clw/Es/3/Sk-1/0453 Alt. 1 And Indication Lamp & Illuminated Push Button Spec. No. Clw/Es/3/0072 Alt. H Or Latest For Three Phase Wap-5 And 7 Locomotive. Warranty Period: 30 Months After The Date Of Delivery
Supply of Soft Starter Control Panel With By-Pass Dol Starter Suitable For 215Hp V Ertical Turbine Pump Floor Mounted Soft Control Panel, Enclosure Of Which Shall Be Made Of 2Mm/1.6Mm Crca Sheet, Dust & Vermin Proof With Power Coated Painting. Aluminum Bus Bar Shall Be Provided In Power Cir Cuit And Control Wiring By 1.5/2.5 Sq.Mm Switchgear Component Shall Be Provided Inside Panel As Below:- Suitabl E Rated Mccb Along With Rated Semi Conductor Fuse. Ac3 Duty Power Contactor 20% Over Range Of Rated Flc Of Motor Before Soft Starter Three Numbers Led Type Indicating Lamps Red, Yellow, Blue For Indication Of Presenc E Of All The Three Phases. Multifunction Meter For Displaying Voltage, Frequency, Ampere, Power & Energy One N O. Single Phasing Preventer Of Reputed Make. Make Of Soft Starter: L&T/Abb/C&S Or Equivalent. As Per Annexur E-1. Warranty Period: 30 Months After The Date Of Delivery
Supply of Micro Controller Based Led Panel For Demu Dpc Coaches Of Size 425Mm Le Ngth X 180Mm Width X 50Mm Depth With 24 Led Indications To Be Powered By Vehicle I Nterface Unit Placed At Engine Cabin Where All The 110V Dc Fault Inputs Will Be Termi Nated. Two Wires For 24V Dc And Two Wires For The Communication Runs From The Ve Hicle Interface Unit To Led Panel. Colour Scheme And Name As Per Bhel Drg.No.158900 30037, Item No.001, Rev.7 Note: Manufacturers Should Indicate Their Identification Mark, Month And Year Of Manufacture At A Suitable Location By Using A Suitable Method Without Affecting The Performance Of The Product. Warranty Period: 30 Months After The Date Of Delivery
Supply of Led Indication Light In Red, Yellow & Blue Colours Dia 22.5Mm, 230V Ac, 50Hz, 0.5Watt, Conf. To Is: 13947, Suitable For Ac Control Panel/Power Panel/Pantry Equipment As Per Rdso Specification No. Rdso/Pe/Spec/Ac/01841-2015 Rev-0.