Supply of Rail Jumper 13 Mtrs Long With Pvc Cable And Rail Clamps At Both Ends As Per Rdso Drg No: Re/ 33/P/500 With Necessary Test And Guarantee Certificate. Followed By I Rail Clamp Made Of Al-Bronze Is 3091/19 99 As Per Rdso Drg.No.Re/33/P/501. Ii Rail Jumper Ferrule As Per Drg.No: Re/33/P/504 Iii Size Of Copper Cabl E Will Be 248/0.45Mm 40 Sqmm As Per Rdso Spec To Is 1554Pt-I1988 Warranty Period: 30 Months After Th E Date Of Delivery
Supply of Inter-Vehicle Power Couplers With E-Beam Cables Overall Length 3000 Mm, Mounting Plates, D Ummy Recp, Coupling Socket- 01 No. & Jumper Plug-01 No. Each Complete Assembly Ready To Use For Part No. 488-750Vivc For Maharaja Express As Per Drawing Attached. Warranty Period: 30 Months After The Date Of Del Ivery
Supply of Jumper Cable Support Link Assembly Stainless Steel, As Per Icf Drg No, Lwscwac/Eog-7-1- 006/Col 1, Alt Nil, With Proper Bracket As Per Icf Drg No. Aab 15007 Warranty Period: 30 Months After Th E Date Of Delivery
Supply Of Usb Connectors Wr-Com Usb Micro Smt Type B Horiztl, Wrdcpj Tht R/A Plasticdcpowerjack Tht R/A Plastic Centerpin Ø2.0, Wr-Phd Weri Pin Header 2, 00Mm 32 Pins, 1 Row, Straight, Gold Plating, Wl-Smcw Smt Mono-Color Chip Led Waterclear 0603, Green Typ, Wl-Smcd Smt Mono-Color Chip Led Diffused0603, Yellow Typ, Wr-Com Usb 2.0 Type C Horizontal Smt Receptacle, Ws-Tasv Tact Switch Washable 4.1*2.8Mm, Vertical Type, Smt, With Groundterminal, 1.27 Mm Jumper Colour: Black, Gold Plating, 2.54 Mm Jumper With Test Point Colour: Black, Gold Plating, Wr-Phd 2.54 Mm Dual Socket Header 16 Pins, Dual Row, Straight, Gold Plating, Ferrite Beads We-Cbf 1206 100Mhz 120Ohm 3000Ma Aecq2, Headers & Wire Housings Wr-Phd 2.54Mm Hdr 4P Dual Str Gold, Power Inductors - Smd We-Mapi 1.2Uh 1.5A Dcr 114Mohms Aec-Q200, Etc
Provision Of Additional Piece Of Contact Wire To Prevent Contact Wire Parting At Rra Locations As Per Smi No. Ti/Mi/0058, Rev. 1, Dtd. 10.08.2021 And Replacement Of 105 Sqmm G Jumper By 160 Sqmm Copper Jumper
Supply of Rail Jumper With Rail Clamp At Both Ends With 03 Meter Long Pvc Copper Cable As Per Rdso Drg. N O. Re/33/P/500 And Rail Clamp Made Of Ai. Bronze Is:3091/1999 Or Latest . Manufacturer Test Certificate And Guar Antee Certificate Are Required With The Supply. Warranty Period: 30 Months After The Date Of Delivery
Supply of Adaptor Jumper Wire Cordless Telephone Switch Port 8 Switch Port 24 Temp Controlled Machine Line Lead Nipper Krone Tool Digital Amp Meter
Supply of P. G. Clamp For 129 Sq.Mm Catenary/ 105 Sq.Mm Jumper/ 150 Sq.Mm To 129 Sq.Mm Catenary/10 5 Sq. Mm Jumper/ 150 Sq.Mm Feeder Wire, As Per C. Rly.Elect/Trd Drg. No., Fm/Dc-Ac/22. Warranty Per Iod: 30 Months After The Date Of Delivery
Supply of Rail Jumper Assembly As Per Drg No Re/33/P/500 Or Latestri No.501 504 505 508 With Both End Clamps Of Al Bronzeand Single Core Flexible Stranded Copper Cable Of 248/0.457 Mm 40 Sqmm Length 15 Mtr & Rail Jumper Assembly As Per Drg No Re/33/P/500 Or Latestri No.501 504 505 508 With Both End Clamps Of Al Bronzeand Single Core Flexible Stranded Copper Cable Of 248/0.457 Mm 40 Sqmm Length 3 Mtr.
Supply Of 105 Sq.Mm. 19 / 7 / 1.016 Annealed Stranded Copper Jumper Wire Large Jumper Wire As Per Rdso Spec. No. Ti/Spc/Ohe/Jmp/0941 Or Latest. Warranty Period: 30 Months After The Date Of Delivery
Maintenance Of Overhead Including Brackets Changing With Defective Bolts And Jumpering Of 6.6 Kv Over Headline At Enm Field Nigahi Project For Monsoon 2024.
Supply Of 50 Sq.Mm Annealed Copper Stranded Jumper Wire, 105Sq.Mm Annealed Copper Stranded Jumper Wire & 160Sq.Mm Annealed Copper Stranded Jumper Wire.The Contract Shall Be For The Period Of 02 Years From The Date Of Rc, Extendable For Further Period With Mutual Consent. 50 Sq.Mm Annealed Copper Stranded Jumper Wire Warranty Period: 30 Months After The Date Of Delivery 105Sq.Mm Annealed Copper Stranded Jumper Wire Warranty Period: 30 Months After The Date O F Delivery 160Sq.Mm Annealed Copper Stranded Jumper Wire Warranty Period: 30 Months After The Date O F Delivery
Supply of Cable Assembly Jumper F-1 For Bt-Memu 10 M As Per Huber & Suhner Part No: 85225075. Mak E Huber & Suhner Or Equivalent. Warranty Period: 30 Months After The Date Of Delivery
Supply of Cable Assembly Jumper B-1 For Bt-Memu 10 M As Per Huber & Suhner Part No: 85225073. Mak E Huber & Suhner Or Equivalent. Warranty Period: 30 Months After The Date Of Delivery
Supply of Cable Assembly Jumper D For Bt-Memu 10 M As Per Huber & Suhner Part No: 85225074. Make Huber & Suhner Or Equivalent. Warranty Period: 30 Months After The Date Of Delivery
Supply of 105 Sq.Mm. Annealed Copper Stranded Jumper Wire As Per Rdso Specification No.Ti/Spc/Ohe/J Mp/0941 Or Latest From Core/Rdso Approved Source Only. Warranty Period: 30 Months From The Date Of Sup Ply Warranty Period: 30 Months After The Date Of Delivery
Supply of Rail Jumper With Both End Clamp With 16 Sq.Mm Copper Cable 3 Mtrs Long For 60Kg Rails As Per D Rwg No.Re/Dnr/El/Tp/07 Or Drg No.Power/584 Or Re/33/P/500 Approved By Indian Railway. Warranty Period: 30 Months After The Date Of Delivery
Supply of High Capacity Inter Vehicular Zs Coupler Of 500A Rating, 750 V For Lhb Coaches Conforming To Rdso Specification No. Rdso/Pe/Spec/Ac/0177-2013 Rev. 0. Qty One Nos.Consist Of 1 01 Nos. Jumper Plug Assembly, 2 01 Nos. Coupling Socket Assembly, 3 01 Nos. Dummy Socket Assembly 4 Jumper Cable Duly Crimpled With Each Jumper Plug And Cover With Flexible Polyamide Conduits And Its Fitting 2.6 Meters 5 Jumper Cables Duly Crimpled With Each Coupler Socket 400 Mm.
Supply of Jumper Cable Support Link Assembly Stainless Steel As Per Drawing No. Lwscwac/Eog-7-1- 006/Col I, Alt-A. Packing Instruction : Spi220 Warranty Period: 30 Months After The Date Of Delivery
Supply of Jumper Cable Support Link Assembly Stainless Steel To Drg No. Lwscwac/Eog-7-1-006/Co L 1, Alt.Nil And With Proper Bracket As Per Icf Drg. No. Aab15007 Note: Material Test Certificate To Be Provid Ed By The Firm. Warranty Period: 30 Months After The Date Of Delivery