Lightning Arrester Tenders

(Select any tender from the list to send an email)
Ref. No #31637506 Central Government/Public Sector Live

Supply of Lightening Arrestor Supply Of Metal Oxide la Heavy Duty Station Class Metal Oxide Gapless Morester Type Stn-D Type Heavy Duty Station Class Metal Oxide Gaples S Morester Type Stn-D Reference Standard Iec 99-4 Of 2006/Is 3070 Part3 1993 No Of Unit One Rated Voltage 30Kv Nominal Discharge Current With Class 10Ka Class 1 Reference Current 2 Ma Pea K Reference Voltage Greater Than Rated Voltage At Reference Leakage Current At Cov Less Than 0.8 Ma M Ax Continuos Operating Voltage 24Kv Rms Maximum Residual Voltage For Discharge Current Of 8/20 Micro Sec Wav E 5000 Amps 85Kvpeak 10000 Amps 90Kvpeak 20000 Amps 100Kvpeak Max Steep Front Residual Voltage At 10 Ka With One Micro Sec Rise Time 100Kvpeak Max Switching Impulse Residual Voltage With 40/80 Us Wave At 1000 A Mps 80Kvpeak Energy Dissipation Capability Form 3 Seqential Shots 6 Kj /Kv High Current 4/10 Us Test Value 100Ka Peak Long Duration Current Tests Current Peak Virtual Duration As Per Discharge Class 2 Of Iec -99-4 Table -4 200 0 Micro Sec Pressure Relief Class Class A Short Circuit Current Capability 40Ka Rms Partial Discharge At 1.05 Time S Mcov Less Than 10Pc 0.1 Second 34.5Ka Rms 0.1 Second 33.5Ka Rms 10.0 Second 31.5Ka Rmsinsulation Withst And Tests On Housing One Minute 50 Hz Dry & Wet 95Ka Rms Impulse Voltage Withstand 175Ka R Ms Creepage Distance Mm 900 Nominal Weight Of Complete Unit 11?10% Kgs Height Of Complete Unit From Bas E To The Line Side Refer Drg No 2500300 Minimum Recommended Contre To Centre Spacing Between s500 Mm Clearance Required Form Ground Equipment At Various Heights Of 400 Mm Earthing Arrangement Pro Vided For Earthing Side Of Ground Terminal Bracket Provided For Connecting Earth Strip Drg No 6220151 M Ounting Flange Dimensional Details End Casting 3 Holes 11Mm 120 Deg Apart At 165Mm Pcd Rated Frequency 50 Hz ? 5% Insulation Material Porcelani Specific Creepage Distance 25Mm/Kv Altitude Above Sea Level 1000/ Mtrs. From Msl Minimum Humidity 85% Markings 99-4 Of 2006/Is 3070 Part3 1993 Earthing Switch Operating M Echanism Independent Manual Drive, Mechanically Interlocked With Main Blades Attached As Per Annexure-A Warranty Period: 12 Months After The Date Of Delivery

Location
Rajasthan
Due Date
14 May, 2024
Amount
Refer Document
Ref. No #31639606 Central Government/Public Sector Live   GeM Tender

Supply of Metal Oxide s Without Gaps As Per Is 3070 Part 3 Q3

Location
Madhya Pradesh
Due Date
08 May, 2024
Amount
2.23 Lacs
Ref. No #31639610 Central Government/Public Sector Live   GeM Tender

Supply of Metal Oxide s Without Gaps As Per Is 3070 Part 3 Q3

Location
Madhya Pradesh
Due Date
08 May, 2024
Amount
31.2 Thousand
Ref. No #31633957 State Government Live

Supply Of 220Kv And 66Kv For Ukai Hps

Location
Gujarat
Due Date
29 Apr, 2024
Amount
9.79 Lacs
Ref. No #31634534 Corporations/Associations/Others Live

Supply Of Material -P.P Reel Insulator -Must Be Of Virgin Plastic Material. Polypropylene Or Equivalent With Break Down Voltage Of 15 Kv, Strain Insulator-Must Of Poly Polypropylene Plastic Rated For 15Kv Uv Stabilized, Corner Post Gi- 8 Ft., Gi-2, 14 Guage Thickness, Painted Having Diametrically Opposite Holes Of Size 6 Mm At Required Interval Of Fencing Installation, Intermediate Post T Angle Post 8 Feet Painted 25Mmx25mmx3mm Having Holes Of Size 6 Mm At Required Intervels Of Fencing Instllation, Supporting Post 6 Feet Gi 1 Inch 14 Guage Thickness Painted, Stay T Angle 2 Feet Painted 25 Mmx25mm X 3Mm, 12 Swg Ht Wire 12 Guage 2.5 Mm Dia High Tensile Wire With Sink Coating For Use As Conducting Wire Winding Strain Insulator, 14 Swg Binding Wire-High Quality Zinc Coating Wire For Binding Reel Insulators, Tighing Support Post With Corner Post, Wire Tightner-Permanant Wire Tighter Made Of Special Aluminium Alloy Designed For Kv, Uv Stabilized, Joint Clamp With Nut And Bolt- Supply Of Joint Clamp With Nuts And Bolt Gi Galavanized Coating For Fastening Conducting Wire Around Posts, Hot Dipped Galvanised , Earth Rod-Copper Plated Earth Rod 14 Mm -3 Ft. Length, Earthing Compound 8 Kg, Tension Spring Spring Steel Cable Of Making Compresion Loads, Galvanised 15Cm Length, Withstand 400Kg , Gate Handle-Steel Rope With Handle And Spring Assembly. Handle Made Of Polyethylene, Lead Out Cable For Fence System Double Insulated Gi Cable Inner Core Wire 2 Sq.Mm. Hot Dipped Galvanised Steel Core, Capable Of With, Standing 15Kv Should Be Provided To Prevent Bimetal Salt Formation At Connections, Single Core 2.5 Mm Sq. Cable-2.5 Mm² Single Core Copper Cable For Connecting The Solar Panel To The Tubular Battery Through Charge Control Unit With Required Terminal Sockets, Nut And Bolt, Washer, Lightining Diverter -15Kv-50Kv Rod Gap , Must Be Capable Of Diverting Stray And Adjustable For Spark Gaps Adequate Earthing To Be Provided, 100 Watt Solar Panel- 100 Watt/ 12 Volt And Above Poly Crystalline With 10 Year Warranty Having Iec/Mnre Certification, Charge Control Unit-20 A 12/24 V Pwm Charge Controller Unit Of Standard Make Suitable To Control The Charging Of The Tubular Battery Energizer With 10 Kv Output Safety Standards To Be Followed Are Bis 302-2-76 Iec60335-2-76. Switch-High, Medium And Low Power Setting. Fence Alarm System Covering Area Of 1.5 Km, Solar Panel Supporting Stand With Metal Box Painted For Battery And Energiser - 18 Guage Thickness Metal Boxlockable - Painted. Gi-Sheet, Painted Should Be Capable Of Housing Batterry, Charge Controller And Energizer And Fixed With Required Clamps And Nut And Bolt On Solar Panel Support Stand Made Of Gi Pipe Of 50Mm Diameter And B Class Type With Suitable Arrangement For Holding The Panel Warning Sign-Polyethylene Plastic With Satuatory Warning With Sign, Tubular Battery 12 V, 100Ah- 12 V, 100 Ah C10 Rating With Full 5 Year Replacement Warranty Tower Battery For Energising The Energiser, Digital Volt Meter- Must Display Fence Voltage Digitally Upto 15Kv . Made Of Non Shocking Plastic, Tool Kit Consisting Of Wire Tighterner Rod, Double Headed Spanner, High Tensile Wire Cutter And Cutting Plier For Installation Of New 5 Line Solar Power Fence

Location
Kerala
Due Date
29 Apr, 2024
Amount
7.58 Lacs
Ref. No #31629761 State Government Live

Testing Of Earth Pit Millwide At Energy - Electrical

Location
Tamil Nadu
Due Date
26 Apr, 2024
Amount
Refer Document
Ref. No #31613709 Central Government / Public Sector Live   GeM Tender

Supply of L. V Bushing Q3 Condenser Bushing Q3 Q3 Neutral Bushing 52Kv1000a Q3

Location
Assam
Due Date
02 May, 2024
Amount
Refer Document
Ref. No #31613934 State Government Live

Supply Of s For 400Kv Switchyard At Wtps

Location
Gujarat
Due Date
24 Apr, 2024
Amount
11.34 Lacs