Supply Of Prismatic Compass, Cross Staff, Optical Square, Dumpy Level With All Standard Accessories, Transit Vernier Theodolite, Tilting Level, Plain Table With Standard Accessories, Orifice Meter, Apparatus For Determination Of Coefficient Of Discharge Contraction And Velocity Through An Orifice, Simple Jib Crane Apparatus, Simply Supported Beam Apparatus, Winch Crab Single Purchase Apparatus, Friction Slide Apparatus, Screw Jack, Le Chatelier Apparatus, Vibrating Table, Vicat Apparatus, Cube Moulds, Standard Sieve Set For Coarse Aggregate, Flakiness Sieve Set, Standard Set Of Sieve For Fine Aggregate, Unconfined Compression Test Machine, Vane Shear Test Motorised, Modified Proctor Test Apparatus, Infra Red Moisture Meter, Liquid Limit Apparatus, Sand Replacement Test Apparatus, Standard Proctor Test Apparatus, Los Angeles Abrasion Testing, Ductility Test Of Bitumen Apparatus, Aggregate Impact Tester With Blow Counter, California Bearing Ration Test, Crushing Value Apparatus, Standard Penetration Test, Rebound Hammer Tester, Bitumen Penetrometer With Automatic Time Controller, Digital Ph Meter, Residual Chlorine Meter, Dissolved Oxygen Meter, Bod Analysis System, Nephelometer, Automatic Digital Conductivity Meter
Supply And Dozing Of Liquid Chlorine Gas At Hsvp Water Treatment Plant, Sector-34, Rohtak And All Other Works Contingent Ther A/Mtc. Water Treatment Plant, Sector-34
Annual Repair And Maintenance Of 320 Kld Sewerage Treatment Plant - Supply Of Bio Culture Of Reputed Firms For Waste Water Management To Reduce Bod Cod Tss As Per The Pcb Norms For Period Of 365 Days 6 Litres Per Day 2190 Ltrs, Supply Of Jeggery Use For Chemical Reaction In Stp To Reduce Bod Cod Tss As Per Pcb Norms For Period Of 365 Days 6 Kgs Per Day 2190 Kg, Supply Of Liquid Chlorine For Period Of 365 Days 6 Litres Per Day 2190 Ltr, Supply Of Decorticated Coil Fiber For Stp 1 Bag 30 Kg, Amc Of 02 Nos Sump Pump 3 Phase 04 Nos 05 Hp And 02 Nos 03 Hp Mono Block Motor 3 Phase Including All Minor Repairs Etc Complete, Operation And Preventive Maintenance Of Stp By One Operator In All Days In A Month, Sample Testing Of Treated Water From Any Nabl Accredited Lab For Following Parameters A Bod B Cod C Tss D Fecal Choliform E Ph, Repairing Of 01 Nos 5 Hp Sump Pump Installed At Stp One Time Repair, Repairing Rewinding And Bearing Of 05 Hp Monoblock Pump Installed At Stp One Time Repair, Repairing Bearing And Sealing Of 03 Hp Monoblock Pump Installed At Stp One Time Repair, Providing And Fixing Of 50 Mm Multi Port Valve For Stp Sludge Water Installed At Stp One Time Repair, Repairing Of Micro Processer Based Stp Panel Installed At Stp One Time Repair, Replacement Of Sprinklers Installed On Chambers For Smooth Functioning Of Stp
Supply of Liquid Chlorine Of 99.9% Vv In 900Kgs Q3