Supply of Precision Relay Socket Model No. V93 Of M/S. Mors Smitt Or Similar, Confor Ming To Iec 571, Iec 77, En 50155. Maximum Overall Dimension: -Width-88 Mm, Length-87 Mm Depth-30 Mm. Mounting Arrangement: - Standard 35 Mm Rail Mounting. Make: - Siemens/ Schneider/Abb/Mors Smitt Or Similar. Warranty Period: 30 Months After The Date Of Delivery Precision Relay In Metro Coaches For Medhamr400 Series Rakes, Conforming To Iec 571, Iec 77, En 50155 Of Mors Smitt D8-U204 Or Equivalent, Coil : Nominal Voltage : 1 10V Dc, Voltage Range 77-137.5 V Dc, Ac 440V/10A Resistanceohms : 3790. Contact Data : Nominal Current 10A Ac Resistive, According To Iec 947 Ac1, Specified Breaking Capa City 0.5A @ 110V Dc, L/R 40 Ms No. Of Contacts : 8 Changeover Contacts Form C. Opera Ting Temperature Range : -25 Degree C To 70 Degree C, Mechanical Dimension Width-88 Mm, Height-40 Mm Depth-54 Mm Or Less/ As Per Site Condition, Mounting Arrangement- Plu G-In Design With Snaplock. Make Siemens/Schneider/Abb/Mors Smitt Or Similar. Warran Ty Period: 30 Months After The Date Of Delivery Precision Relays In Metro Coaches For Medhamr400 Series Rakes, Utilizat Ion Category-Dc-13 Conforming To Iec : 60947-1 To Iec : 60947-5. Of Siemens 3Rh2122-2Xf40-0La2 Or Equivalent.Operating Voltage Control Circuit, Control- Dc 72-125V Auxiliary Cir Cuit 110V Dc, 1A To 3A, Mechanical Dimension-Width-45Mm, Height 70Mm Depth-73Mm Or L Ess/ As Per Site Condition, Mounting Arrangement- Snap-On Mounting On To Standar D 35Mm Mounting Rail According To Din En 50022 Type Of Auxiliary- 2 No+2 Nc. Make Siem Ens/Schneider/Abb Or Similar. Warranty Period: 30 Months After The Date Of Delivery Precision Relays In Metro Coaches For Medhamr400 Series Rakes, Utilizat Ion Category-Dc-13 Conforming To Iec : 60947-1 To Iec : 60947-5. Of Siemens 3Rh2131-2Xf40-0La2 Or Equivalent.Operating Voltage Control Circuit, Control- Dc 72-125V Auxiliary Cir Cuit 110V Dc, 1A To 3A, Mechanical Dimension-Width-45Mm, Height 70Mm Depth-73Mm Or L Ess/ As Per Site Condition, Mounting Arrangement- Screw And Snap-On Mounting On To Standard 35Mm Mounting Rail According To Din En 50022 Type Of Auxiliary- 3 No+1 N C. Make Siemens/Schneider/Abb Or Similar. Warranty Period: 30 Months After The Date Of Delivery Precision Relays In Metro Coaches For Medhamr400 Series Rakes, Utilizat Ion Category-Dc-13 Conforming To Iec : 60947-1 To Iec : 60947-5. Of Siemens 3Rh2140-2Xf40-0La2 Or Equivalent. Operating Voltage Control Circuit, Control- Dc 72-125V Auxiliary Cir Cuit 110V Dc, 1A To 3A, Mechanical Dimension-Width-45Mm, Height 70Mm Depth-73Mm Or L Ess/ As Per Site Condition, Mounting Arrangement- Screw And Snap-On Mounting On To Standard 35Mm Mounting Rail According To Din En 50022 Type Of Auxiliary- 4 No. Ma Ke Siemens/Schneider/Abb Or Similar. Warranty Period: 30 Months After The Date Of Delivery Precision Mpcb/Circuit Breaker In Metro Coaches For Medhamr400 Series Rakes, Conforming To Iec : 60947-2 To Iec : 60947-4-1 Of Siemens 3Rv2021-4Na10 Or Equivalent. Operating Voltage- At Ac-3 Rated Value 690V, No. Of Poles : 3, Operating Current- At Ac- 3 At 400V Rated Value : 28A Adjustable Pick-Up Value Current Of The Current-Dependen T Overload Relaease : 23-28A, Trip Class : Class 10, Response Value Current Of The Ins Tantaneous Short-Circuit Release : 364A, Mechanical Dimension-Width-45Mm, Height-97 Mm Depth-96Mm Or Less/ As Per Site Condition, Mounting Arrangement- Screw And S Nap-On Mounting On To 35Mm Standard Mounting Rail According To Din En 60715. Make Siemens/Schneider/Abb Or Similar. Warranty Period: 30 Months After The Date Of Delivery Precision Auxiliary Contact Block For Mpcb In Metro Coaches For Medha Mr400 Series Rakes, Conforming To Iec : 60947-5-1 Of Siemens-3Rv2901-1F Or Equivalent. Rati Ng 2.5A/240V Ac, No. Of Contact : 2 No, Mechanical Dimension Width-45Mm, Height-12Mm D Epth-17Mm Or Less/ As Per Site Condition, Type Of Electrical Connecttion For Auxili Ary And Control Current Circuit : Screw Type Terminal, Mounting : Plug-In Fixing. Ma Ke Siemens/Schneider/Abb Or Similar. Warranty Period: 30 Months After The Date Of Delivery Precision Mpcb/Circuit Breaker In Metro Coaches For Medhamr400 Series Rakes, Conforming To Iec : 60947-2 To Iec : 60947-4-1 Of Siemens 3Rv2011-1Ea10 Or Equivalent. Operating Voltage- At Ac-3 Rated Value 690V, No. Of Poles : 3, Operating Current At Ac-3 At 400V Rated Value : 4A Adjustable Pick-Up Value Current Of The Current-Dependent Overload Relaease : 2.8-4A, Trip Class : Class 10, Response Value Current Of The Insta Ntaneous Short-Circuit Release : 52A, Mechanical Dimension-Width-45Mm, Height-97Mm Depth-96Mm Or Less/ As Per Site Condition, Mounting Arrangement-Screw And Snap- On Mounting On To 35Mm Standard Mounting Rail According To Din En 60715. Make Siem Ens/Schneider/Abb Or Similar. Warranty Period: 30 Months After The Date Of Delivery
Supply of Mpcb For Water Pump 1 & 2 With Aux. Contact 1No+1Nc And Terminal Block Db, Pole 3 P Rated Current - 1 To 1.6 A Rated Voltage 690V, Class-10, Breaking Capacity 50Ka, Make : Abb Cat No. Ms 116-1.6, Hk1-11, Scheider Cat No. Gv2-Me 06 + Gvae11, Siemens - Cat No. 3Rv20111aa10+3Rv2901-1E, L&T Cat No. St418940000 + St419450000 Warranty Period: 30 Months After The Date Of Delivery
Supply of Mpcb Current Rating 16 Ampere Thermal Release Range 10-16 Ampere Class-10, Breaking Capacity 50 Ka, 3 Pole Voltage, 415 V Ac Conf. To Rdso Specs No. Rdso/Pe/Spec/Ac/0184-2015 Rev-0 Suitable For C Ompressor Of Lhb Ac Coaches. Warranty Period: 30 Months After The Date Of Delivery
Supply of Motor Protection Circuit Breaker Mpcb Range 6.3 To 10 Amps As Per Edts 110 Re V Nil Or Latest Warranty Period: 30 Months After The Date Of Delivery
Supply Of Cb-Moulded Case Circuit Breaker 5530900196, Mpcb 3P 230V 25A 3 2 5A 1No 1Nc 60A 5530900197, Cb5 Motor Protection Circuit Breaker 5530900200, Air Break Contactor 415V 32A 3 Pole With 5530900204, Ml6 Contactor 230V Ac 2No Plus 2Nc Ss909218000, Bimetal Thermal Overload Relay Thermal 5530900207, Dc Contactor 2No 2Nc 2P 110Vdc 60A 5530900220, Current Limiting Block F H S C 5530900234, Contact Switch 4P 3Way 16A 400V F Hoist 5530900235, 2P 2Way F 250V Crown Cntrl Swtch 5530900236, Dc Ammeter For Hoist Motor Current 5530900252, Dc Volt Meter For Exciter Voltage 5530900251, 3000V 16A Fose Lenk 2Kb3 642T2 Fh1 5530900192, 3 3Kv Hrc Fuse 160A 100A A81sv X 5530900193, Air Distribution Valve With Solenoid 110V Dc G225, L V Ring Bracket 3Ta27850, Ht Brass Pad Thickness 12Mm With 4 Fixing Screw 8Md72003, Ht Ring Insulator Height Range 135 138Mm Stb780078135, Hose 9151320220, Round Rubber Coupling Pad Dia 32Mm Length 65Mm 32 65 Mm
Supply of Mpcb 1.0 To 1.6 Amp To Intec Part No.Icac-101 For Roof Mounted Air Conditioning System Of Cab Ac As Per Rdso Specification No.Rdso/2007/El/Spec/0055 Rev.2. Warranty Period: 30 Months After T He Date Of Delivery
Supply of Mpcb 4.0 To 6.3 Amp To Intec Part No.Icac-102 For Roof Mounted Air Conditioning System Of Cab Ac As Per Rdso Specification No.Rdso/2007/El/Spec/0055 Rev.2 Warranty Period: 30 Months After T He Date Of Delivery
Supply of Mcb 3 Pole 10 Amps. Make: L&T / Abb / Siemens / Schneider / Legrand. Note: 1 Item Should Be Suitable For 2T Capacity Roof Mounted Cab Ac Of Make Daulatram / Fedders Lylord / Sidwal Fitted In Conventional Electric Locos To Rdso Specification No: Rdso/2007/El/Spec/0055 Rev.2 Of Nov 2007/Revised On 07.10.2014. 2 One Sample To Be Got Approved Before Effecting Bulk Supply. Mcb 3 Pole 16 Amps. Make: L&T / Abb / Siemens / Schneider / Legrand. Note: 1 Item Should Be Suitable For 2T Capacity Roof Mounted Cab Ac Of Make Daulatram / Fedders Lylord / Sidwal Fitted In Conventional Electric Locos To Rdso Specification No: Rdso/2007/El/Spec/0055 Rev.2 Of Nov 2007/Revised On 07.10.2014. 2 One Sample To Be Got Approved Before Effecting Bulk Supply.. Mpcb 4-6.3 Amps. Make: L&T / Abb / Siemens / Schneider. Note: 1 Item Should Be Suitable For 2T Capacity Roof Mounted Cab Ac Of Make Daulatram / Fedders Lylord / Sidwal Fitted In Conventional Electric Locos To Rdso Specification No: Rdso/2007/El/S Pec/0055 Rev.2 Of Nov 2007/Revised On 07.10.2014. 2 One Sample To Be Got Approved Befo Re Effecting Bulk Supply. Warranty Period: 12 Months After The Date Of Delivery Mpcb 1-1.6 Amps. Make: L&T / Abb / Siemens / Schneider. Note: 1 Item Should Be Suitable For 2T Capacity Roof Mounted Cab Ac Of Make Daulatram / Fedders Lylord / Sidwal Fitted In Conventional Electric Locos To Rdso Specification No: Rdso/2007/El/S Pec/0055 Rev.2 Of Nov 2007/Revised On 07.10.2014. 2 One Sample To Be Got Approved Befo Re Effecting Bulk Supply. Warranty Period: 12 Months After The Date Of Delivery Mcb 2 Pole 10 Amps. Make: L&T / Abb / Siemens / Schneider /Legrand. Note: 1 It Em Should Be Suitable For 2T Capacity Roof Mounted Cab Ac Of Make Daulatram / Fed Ders Lylord / Sidwal Fitted In Conventional Electric Locos To Rdso Specification No: Rdso/2007/El/Spec/0055 Rev.2 Of Nov 2007/Revised On 07.10.2014. 2 One Sample To Be Got A Pproved Before Effecting Bulk Supply. Warranty Period: 12 Months After The Date Of Delivery Mcb 3 Pole 10 Amps. Make: L&T / Abb / Siemens / Schneider / Legrand. Note: 1 It Em Should Be Suitable For 2T Capacity Roof Mounted Cab Ac Of Make Daulatram / Fed Ders Lylord / Sidwal Fitted In Conventional Electric Locos To Rdso Specification No: Rdso/2007/El/Spec/0055 Rev.2 Of Nov 2007/Revised On 07.10.2014. 2 One Sample To Be Got A Pproved Before Effecting Bulk Supply. Warranty Period: 12 Months After The Date Of Delivery Mcb 3 Pole 16 Amps. Make: L&T / Abb / Siemens / Schneider / Legrand. Note: 1 It Em Should Be Suitable For 2T Capacity Roof Mounted Cab Ac Of Make Daulatram / Fed Ders Lylord / Sidwal Fitted In Conventional Electric Locos To Rdso Specification No: Rdso/2007/El/Spec/0055 Rev.2 Of Nov 2007/Revised On 07.10.2014. 2 One Sample To Be Got A Pproved Before Effecting Bulk Supply. Warranty Period: 12 Months After The Date Of Delivery
Disposal Of Hazardous Waste Generated In Sanpada Workshop As Per Consent By Maharashtra Pollution Control Board Mpcb.
Provision Of Individual Mpcb For Water Pumps And Shifting Of Its Controller To Onboard In Set Of Panels For Lhb Non-Ac Eog/Hog Coaches
Supply of Motor Protection Circuit Breaker Mpcb For Power Car Control Panels For Ventilator Fans. Thermal R Ange-6.3-10A With 01 No+01 Nc Block 3 Pole.Make-Aeg Model No.-910-201-209, Siemens Model No.-3Vu 1340-1Ml00, Spreacher+Schuh Model No.-Kta3-25-10A, Equivalent Abb Make Warranty Period: 30 Month S After The Date Of Delivery
Provision Supply & Erection Of Individual Mpcb For Water Pumps And Shifting Of Its Controller To On Board In Set Of Panels For Lhb Non-Ac Coaches As Per Rdso Modification Sheet No. Rdso/Pe/Ms/Tl/0090- 20 23 Rev.0 With Supply And Erection Of Following Items 1 Mpcb For Water Pump 1& 2 With Aux. Contact 1No+1 Nc And Terminal Block Db, Rated Current: 1- 1.6 A Thermal Release Range: 1-1.6 A Rated Voltage: 690 V Make A Bb Ms116-1.6, Hk1-11, Schneider Gv2-Meo6+Gv-Ae11, Siemens 3Rv20111aa10+3Rv 2901-1E- 01 Nos 2 Supply 1.5 Sq.Mm Copper Cable Single Core Thin Walled Electron Beam Cross Linked Polymer 1.8 Kv Grade Confor Ming To Elrs/Soec/Elc/0019 Rev 3 Feb 2017 Make As Per Rdso Approved- 140Mts 3 Supply Of Polyamide -6Pa-6 Flexible Conduit Pipe Of Nominal Size Nw12od:15.8+0.2Mm As Per Rdso Specification Rdso/Pe/Sp Ec/Ac/0138-2009Rev-1-40Mtrs 4 Wago Type Fuse Base 6 Sqmm With Link-2Amps- 02 Nos 5 Grommet-15Mm -04 Nos 6 Din Rail35mmx7.5Mm For Fixing Of Wago-01 Nos Warranty Period: 30 Months After The Date Of D Elivery
Supply of Mpcb Motor Protection Circuit Breaker Of Current Rating: 1.6 Amps, Thermal Release Range: 1.1 To 1.6 Amps, Class-10, Breaking Capacity: 50 Ka, 3 Pole, Voltage Rating 415 V Ac With 01 No + 01 Nc Auxiliary Co Ntact Block As Per Rdso Spec. No. Rdso/Pe/Spec/Ac/0184-2015 Rev.1 To Abb Model No.:Ms132-1.6B, Sch Neider Model No. Gv2me06, L&T Model No. St41894oooo, Siemens Model No. 3Rv2011-1Aa10 And Eaton Model No. Pkzm0-1.6. Warranty Period: 30 Months After The Date Of Delivery
Supply of Set Of Following 05 Items Consisting Of 1 Contactor 12 Amps. Make: L&T / Si Emens / Schneider / Abb / Bch - Qty - 20 Nos / Set. 2 Contactor 9 Amps. Make: L&T / Siemens / Schneider / Abb / Bch - Qty - 20 Nos / Set. 3 Auxiliary For Contactor For Mpcb. Make: L&T / Siemens / Schneider / Abb / Bch - Qty - 20 Nos / Set. 4 Overload Relay - 0-6.6 Amps. Make: L&T / Siemens / Schneider / Abb / Bch / Wq - Qty - 20 Nos / Set. 5 Change Over Switch 3 Phase, 40 Amps. Make: L&T / Siemens / Schneider / Abb / Bch - Qty - 20 Nos / Set. Note: 1 Item Should Be Suitable For 2T Capacity Roof Mounted Cab Ac Of Make Daulatram / Fedders Lylord / Sidwal Fitted In Conventional Electric Locos To Rdso Specification No: Rdso/2007/El/S Pec/0055 Rev.2 Of Nov 2007/Revised On 07.10.2014. 2 One Sample To Be Got Approved Befo Re Effecting Bulk Supply. Warranty Period: 12 Months After The Date Of Delivery