Programme Switch Tenders

(Select any tender from the list to send an email)
Ref. No #31609549 Central Government/Public Sector Live

Supply of Srph154036-Mri Conditional Dual Chamber Pacemaker Rate Responsive Ddd R With Appropriate Atrial And Ventricular Bipolar Steroid Eluting Lead Mri Conditi Onal With Life Warranty Provision Of Pacing Therapy For The Use Of The Patients Lif E-Time Including Any No. Of Pulse Generator Replacements As Clinically Required. S Hould Have The Latest Technological Features To Provide Proportionate, Smooth A Nd Appropriate Response Of Pacing Rate To Increased Metabolic Demand, Should Pr Ovide For Atrial And Ventricular Pacing And Sensing With Choice Of At Least 16 Mode S Of Operation, Appropriate Safety Features To Avoid Cross Talk, Optimum Flexibilit Y Of Programming Including Minimal Av Delay Of 30Msec Or Less And Atrial Sensitivit Y Of 0.2Mv Or Less, Detailed Data Storage With Easy Retrieval And Display Of Advanc Ed Diagnostics For Ease Of Clinical Follow Up & Maximal Longevity. Should Be Capabl E Of Programming For Prolonging Longevity And Maximal Cost Effectiveness. Shoul D Be Capable Of Providing Reliable Ventricular Capture With Lowest Battery Drain S O As To Provide Maximum Longevity Of The Pacing System. Preferably As An Automati C Feature Where The Pulse Generator Can Perform A Periodic Threshold Test And R Eliably Verify Ventricular Capture And Adjust Ventricular Pulse Output Parameter S To Minimize Battery Drain Without Compromising Patient Safety. Should Have Feat Ures For Automatic Management Of Arrhythmias Including Pacemaker Mediated Arr Hythmias As Well As Automatic Mode ing Mode Should Be To And From Ddd To Ddi/Vvir, Provision Of Rate Responsive Pacing After Mode And Automat Ic Reversion To Ddd After Termination Of Mode Triggering Arrhythmias. Sho Uld Have Algorithms To Promote Intrinsic Conduction. Both Atrial And Ventricular Channels Should Have Provision For High Energy Output I.E. Up To At Least 6.0 Volts Pulse Amplitude And Pulse Width Up To Atleast 1.0 Ms, Follow Up Diagnosis And Repro Gramming Should Be Rendered As Effective As Possible Through Provision Of Adequ Ate Information Management Systems On The r. Mri Compatible Leads Sho Uld Be Bipolar, Steroid Eluting And Low Profile Either Tined Or Active Fixation Type 7F Or Smaller Introducer Individually. Leads Should Be From The Same Manufacture R I.E. Manufactured By The Same Company As The Pulse Generator, Not Outsourced A Nd Marketed By Another Company. Pulse Generator And Leads Should Be Suitable Fo R Adult And Paediatric Patients. The Manufacturer / Supplier Should Submit Proof O F Supply To A Major Government Institute. Publications Supporting The Safety And E Fficacy Of The Pacemaker Device And The Leads In Clinical Use Should Be Available In Peer Reviewed Journals. The Latest r With Up Dated Software Should Be Available At All Times Permanently In The Hospital. The r Should Have Fac Ilities For Simultaneous Display Of Multiple Surface Ecg Leads, Intracardiac Electr Ograms, Event Markers, Electronic Calipers And For Recording The Same Both On P Aper And In Electronic Storage Media E.G. Compact Disc Etc., Unit:No

Location
Tamil Nadu
Due Date
03 May, 2024
Amount
Refer Document
Ref. No #31603082 Central Government/Public Sector Live   GeM Tender

Supply Of Actuator Seal Kit, Inboard Bearing, Pressure Gauge 0-250Bar, 63Mm Dial, 150A, 380V, 50Hz, 3 Ph Auto Change Over , 50A, 380V, 50Hz, 3Ph Auto Change Over , 20A, 380V, 50Hz, 3Ph Auto Change Over , 300A, 380V, 50Hz, 3 Ph Auto Change Over , Pneumatic Hose Pipe, Logic Controllerplc, Mcb Tp 63A, Mccb-125A, Mccb-50A, Motorised Mechanism For 250 Mccb/160/200A Mccb, Motorised Mechanism For 400/630, Contactor Rated 70A 110V Ac Operating Coil With 2No+2Nc, Fuse 16A Ns16, Hcos, 380V, 3Phase, 50 Hz, 200A, Hcos, 380V, 3Phase, 50 Hz, 300A, Electrical Motor, Local Control Panel, Analog Output Module, Vme Ip Carrier, Digital Output Module, Analog Input Module, Digital Input Module, 32 Channel Di Pcb, Do Pcb With 12 Relays, Keyboard, Fiber Sfp Module, Exhaust Fan, Rectifier Unit, Flame Detector, Programming Tool, Exi 800 Mx Is Loop Interface, Whirling Psychrometer, Hrc Fuse, Fuse Link 4A, Hrc Fuse, Fuse Link 16A, Hrc Fuse, Fuse Link 6A, Indicating Lamp Blue Led, Mcb 16A 2 Pole Current Rating 16A, 24 Vdc, Kw Meter, Under Voltage & Over Voltage Relay, Selco S6000, E-1032 Hmi Display Power Supply 24V Dc, Interposing Relay, Illuminated Push Buttons-Red, Rtu Power Supply Card, Ml2 Contr.2No+2Nc 240V Ac, Auxiliary Relay Ac, Power Line Filter, Terminals Cst 6, Indicating Lamp Red, B90 Trackball Unit, 100A Mccb, Mccb-200A, 250A Mccb, Circuit Breaker 630A, Fuse 10A Ns10, Roller Dia 40, Roller Dia 50, Retractable Roller, Test Electronic Card, Power Electronic Card, Supply Electronic Card, Mfw Processor, Adressable Call Point Wether Proof, Smoke Detector Water Tight, Motor Vision Relay, Indicating Lamp Yellow, Indicating Lamp White, Control Transformer, Indication Lamp Red, 415V, Mcb 6A 2 Pole Current Rating 6A, 24 Vdc, Mcb 4A 2 Pole Current Rating 2A, 24 Vdc, Mcb 20A 2 Pole Current Rating 20A, 24 Vdc, U-V-O-V Reay, Acos Pcb B, Control Transformer, 415/230V, 100Va, 60A Hcos, 125A Hcos, Control Terminals Cst 2.5, Toggle 10A 1 Pole With Legend Plate, Kw Meter 0-600 Kw, Temperature Check Electronic Card, Cartridge Fuse 50A

Location
Andhra Pradesh
Due Date
29 Apr, 2024
Amount
Refer Document