Procurement Of Spares For 3300V Nflp Dol Starter Make Sait Mine Line Under Pac 3 P, On Off Isolator One To One Fitment To Part No. 0201080011, Vacuum Contactor, Rating 3.3Kv One To One Fitment To Part No. 0601010064, Vacuum Interrupter Bottle 3.3Kv 400A One To One Fitment To Part No. 0701020018, Aux. Contactor 2 No 2 Nc One To One Fitment To Part No. 0201010048, Earth Leakage Relay Cbct80, 2 To 5A 220V One To One Fitment To Part No. 0601010008, Ct 100 5, 5Va One To One Fitment To Part No. 0201040028, Ammeter S72, Range 0 To 200 100 One To One Fitment To Part No. 0201100041, Ammeter Selector Switch One To One Fitment To Part No. 0201080043, Voltmeter0 To 4 Kv, Ptr 3.3 Kv 220 V One To One Fitment To Part No. 0201100096, Volt Meter Selector Switch One To One Fitment To Part No. 0201080049, Over And Under Voltage Relay One To One Fitment To Part No. 0201030328, Push Button Actuator Green One To One Fitment To Part No. 0201060007, Push Button Actuator Red One To One Fitment To Part No. 0201060008, Push Button Element, 1No 1Nc, 10A One To One Fitment To Part No. 0201060021, Pt, 3P, 3.3Kv 110V, 500Va One To One Fitment To Part No. Htptl33, Busbar Support, Bs 60 One To One Fitment To Part No. 0601030045, Indicating Lamp, 6W, 220V Ac One To One Fitment To Part No. Elad220vac, Control Fuse, 10A One To One Fitment To Part No. 0308020002
Procurement Of Spares - Remote Winding Temparature Indicator For Hv Lv 90260V Acdc P21p22 As Per Toshiba Doc No Ttd1ehvms20211, Auxillary Power Supply Transformer For Oltc Pannel 41555055V 500Va, Oltc Gear Box With Motor 3 Phase Ip55 1250Rpm, Selector Switch Rtcc Pannel, Temperature Selector Switch Oltc Pannel, Tap Position Indicator For Rtcc Pannel 90V260v Acdc 25 Tap1 Kohm Step, Aircel Rapture Relay F54 For 80Mva Trafo, Oil Surge Relay For Oltc F52 For 80Mva Trafo, Hv Bushings With Metal Parts And Gas Cuts For 250Kv Auxtrafo 25 Dia 33Kv Ac, Lv Bushings With Metal Parts And Gas Cuts For 250Kv Auxtrafo 415V Ac, Silica Gel Breather 1 Kg, Neutral Bushing With Metal Parts And Gas Cut Set Hv Porcelain Type 36Kv630a, Neutral Bushing With Metal Parts And Gas Cut Set Lv Porcelain Type 36Kv2000a, Ptr Lv Terminal Connector Acsr Moose, Ptr Hv Terminal Connector Acsr Moose, Master Trip Relay Mvajm25 Burden High Flush Mtg Case Size 4 Aux Voltage 220V Dc Contact Combination18no2nc Erhr With Flag Mvajm25, Dc Supervision Relay Mvaam11 Single Element Voltage Operated Auxrelay Auxvoltage220v Dc Contact Comination 2No2co Sr Flush Mounting Case Size2 Reverse Flag Indicator, Auxiliary Relay 10 No Sr Flagyes220250v Dcwd01mvajm11011 Mvajm11ja1000a, Auxiliary Relay Dc Changeover 2M 2C Srflagyrd110125220250v Dc Wdz1mvaam1101sht1 Mvaam11b1ba2530a, Dc Supply Super Vision Relay 4B Srflagrev220250v Dc80120 Ms Tddcwdz1mvaam11009sht1 Mvaam11b1cj1015a, High Speed Tripping Relay Supervision Relay 1M 2B Sr220250v Dcflagrevwdf1mvaxm21001 Mvaxm21c1ce3005a, Ac Super Vision Relay 4B Srflagrev240v 50 Hz80120 Ms Tddo Wdz1mvaam11010sht1 Mvaam11bcj5515a, Tddo Wdz1mvaam11010sht1 Mvaam11bcj5515a, Control Relay Er Low Burdenvoltage Sel Relay 8 No2 Nc Erfollow On Flag 220250V Dcwd01 Mvajm14011 Mvajm14jb1002a1, High Speed Tripping Relay Lv Trip Relay220250v Dcelectricalhand Reset8m 2B Contact Configcase Size 2 Wd01mvajm15011 Mvajm15ja1002a, High Speed Tripping Relay Hi Budenflagyes Hr Flag220250v Dc18m 2B Erhrwd01mvajm25011sht1 Mvajm25la1002a, Auxiliary Relay 12 No Sr Flagno220250v Dcwd01mvaam31010 Mvaam31c1aa1001a, Dc Supply Super Vision Relay Maam11b1cj5516a, F650 Relay F650nxjf1g1hi6he, 33Kv Vacuum Circuit Breaker Indoor Type Ur36kv Fr50hz Up170kvpstc315ka3sec Sus Bar Rated Ir3000a Normal Ir2500a 3Aho 3156, 33Kv Vacuum Circuit Breaker Indoor Type Ur36kv Fr50hz Up170kvpstc315ka3sec Sus Bar Rated Ir3000a Normal Ir1600a 3Aho 3153, Ac Indicator Lamps For Rtcc Pannel Red Colour, Ac Indicator Lamps For Rtcc Pannel Green Colour, Mcb Q33q34 415V Ac 3Pole 2A, Mcb Q35 240415V Ac 2Pole 6A, Mcb Q36 240415V Ac 2Pole 10A, Mcb Q37 240V Ac 1Pole 2A, Mcb Q38 240V Ac 1Pole 6A, Mcb Q40 415V Ac 3Pole 10A, Mcb Q41 415V Ac 4Pole 16A, Mcb Q1 To Q8 415V Ac 4Pole 2A, Numerical Relay Ocef Protection7sr 7Sr22032ba870ca0 220 Dc 13Bi14bo, Mcb32a Breaking Capacity 10Ka Rating 32A Pole 2 Voltage 240V Ac With Fixed Thermal Ol Mgt Sc Release 5Sl42327rc, Mcb16a Breaking Capacity 10Ka Rating 16A Pole 2 Voltage 110V Ac 240V Ac With Fixed Thermal Ol Mgt Sc Release 5Sl42167rc, Mcb2a Breaking Capacity 10Ka Rating 2A Pole 4 Voltage 110V Ac With Fixed Thermal Ol Mgt Sc Release 5Sl44027rc, Mcb6a Breaking Capacity 10Ka Rating 6A Pole 2 Voltage 220V Ac With Fixed Thermal Ol Mgt Sc Release 5Sl52067rc, Mcb6a Breaking Capacity 10Ka Rating 6A Pole 2 Voltage 240V Ac With Fixed Thermal Ol Mgt Sc Release 5Sl42067rc, Mcb6a Breaking Capacity 10Ka Rating 6A Pole 1 Voltage 240V Ac With Fixed Thermal Ol Mgt Sc Release 5Sl41067rc, Mcb4a Breaking Capacity 10Ka Rating 4A Pole 2 Vol 240V Ac With Fixed Thermal Ol Mgt Sc Release 5Sl42047rc, Mcb25a Breaking Capacity 10Ka Rating 25A Pole 2 Voltage 220V Dc With Fixed Thermal Ol Mgt Sc Release 5Sl52257rc, Mcb6a Breaking Capacity 10Ka Rating 6A Pole 2 Voltage 220V Dc With Fixed Thermal Ol Mgt Sc Release 5Sl52067rc, Lt Auxillary Contactor Knrfkcetkbet3 Air Break In Open Execution 4Pole Auxcontacts 2No2nc Operating Coil 220V Dc 3Th30 220Bm4, Lt Auxillary Contactor Kdc11kdc12 Air Break In Open Execution 4Pole Auxcontacts 3No1nc Operating Coil 220V Dc 3Th30 310Bm4, Lt Auxillary Contactor Kspxktrxksrsk60pklrxkrlxk95ax95bx K60mkbet1kbet2 Air Break In Open Execution 4Pole Auxcontacts 4No Operating Coil 220V Dc 3Th30 400Bm4, Lt Auxillary Contactor K70ak70bk80axk80bxkfaxkb Air Break In Open Execution 4Pole Auxcontacts 2No2nc Operating Coil 220V Ac 3Th30 220Ap0, Power Contactor Q20 Current 9A Voltage 240V Ac 3Pole 3Tf30 100Ap0, Auxillary Contactor Kbet1kbet2 1Nc Auxcontactor Block 3Th30 Contactor 3Tx4 0012A, Auxillary Contactor Kcetkbet2kbet3 1N0 Auxcontactor Block 3Th30 Contactor 3Tx4 0102A, Green Led Lampcomplete Unit H0 Green Led Lampvoltage 220V Dc 3Sb52856he05, Red Led Lampcomplete Unit, H1h13ah13bh14h15ah15b Red Led Lamp Voltage 220V Dc 3Sb52856hc05, Amber Led Lampcomplete Unit H4 Amber Led Lamp Voltage 220V Dc 3Sb52856hl05, White Led Lampcomplete Unit H5ah5bh10 White Led Lamp Voltage 220V Dc 3Sb52856hg05, Blue Led Lampcomplete Unit H6 Blue Led Lamp Voltage 220V Dc 3Sb52856hf05, Yellow Led Lampcomplete Unit H11 Yellow Led Lamp Voltage 220V Dc 3Sb52856hd05, Red Led Lampcomplete Unit H7 Red Led Lamp Voltage 635V Ac 3Sb52356hc14, Yellow Led Lampcomplete Unit H8 Yellow Led Lamp Voltage 635V Ac 3Sb52356hd14, Blue Led Lampcomplete Unit H9 Blue Led Lamp Voltage 635V Ac 3Sb52356hf14, Red Led Lampcomplete Unit H12ah12bh16 Red Led Lamp Voltage 240V Ac 3Sb52856hc03, Mcb6a F22b Breaking Capacity 10Ka Rating 6A Pole 2 Voltage 220V Dc With Fixed Thermal Ol Mgt Sc Release 5Sl52067rc, Mcb16a F20af20b Breaking Capacity 10Ka Rating 16A Pole 2 Voltage 110V Ac 240V Ac With Fixed Thermal Ol Mgt Sc Release 5Sl42167rc, Mcb6a 220 V Ac 6A 50Hz Single Pole Mcb, Lt Auxillary Contactor K70a Air Break In Open Execution 4Pole Auxcontacts 2No2nc Operating Coil 220V Ac 3Th30 220Ap0, Mcb 4P 32Aac, For Pooling Substations
Supply Of Spares For Prabhu Make Ht Starter Isolator 200 Amp 3 Point 3 Kv On Off Part No Ht100, Isolator Fixed Contact Set Part No Ht1001, Isolator Moving Contact Set Part No Ht1002, Vacuum Contactor 400 Amps 3 Point 3 Kv Part No Ht200, Vacuum Contactor Rectifier Bridge Part No Ht201, Vacuum Contactor Closing Coil 110V Dc Part No Ht203, Vacuum Contactor Holding Coil 110V Dc Part No Ht204, Auxiliary Switch For Vacuum Contactor 2N Part No Ht205, P T 40Va 0 8 12V 0 110V Part No Ht206, Auxiliary Contactor 3No Plus 1Nc 110V Part No Ht208, Resin Cast P T 750Va 3 Point 3Kv 110 Volt Part No Ht300, Ht Control Fuse 3 Point 3Kv 2Mps Part No Ht400, Resin Cast Moulded Ct For O L Relay 75 Part No Ht600, Resin Cast Moulded Ct For Ammeter 150 5 Part No Ht650, Dmc Moulded 3 Point 3Kv Insulator For Power Fu Part No Ht700, Earth Leakage Relay Unit Complete Witho Part No Ht800, 3 Pole Magnetic O L Relay Part No Ht900, O L Rly Thrml 4 7 5 A Ct Oprtd W Mntng Part No 900B, 72Sq Mm Ammeter 0 150 450A Part No Ht1000, 72Sq Mm Voltmeter 0 5Kv Part No Ht1100, Ammeter Selector Switch Part No 1001, Hrc Fuse Base And Carrier For Control Part No Ht1200, Hrc Fuse Link For Control Part No Ht1201, Push Button With Element For Start Sto Part No Ht1300, Lamp Holder With Lamp On Off Trip Part No Ht1400, Power Hrc Fuse Part No Ht1500, Brass Cable Gland Complete With Ci Clam Part No 1600, Cable Box Complete W O Gland For I C T Part No 1600A, Terminal Chamber For I C T G O G And Pa Part No 1600B, Isolator Handle On Off With Axel Bush Part No 1501, Isolator Limit Switch Part No Ht1700, Single Phasing Preventor With Module Part No Ht2001, Static Type Idmtl Over Current And Short Part No Ht900a, Voltmeter Selector Wsitch Part No Ht1101, Contactor Tp 12 Amps Ac3 Duty Fitted Wit Part No Ht200a, Diode By255 For Vacuum Contactor Part No Ht200c, Copper Bus Bar 400 Amps Set Of 3 Part No Ht101, Pilot Realy 12Dc Part No Ht2200
Supply And Delivery Of Cg Make Vacuum Contactor For Soft Starter At Chetla Bps
Supply of Pump Spares Of M And P Make Pump Model, 123 Vaccum Contactor 400Amp 6.6Kv Grade Diode By255 For Vacuum Contactor Vacuum Contactor Rectifier Bridge Bottle Fvcum Cntctr 400Amps. 6.6Kv Vacuum Contactor Closing Coil 110V Dc Vacuum Contactor Holding Coil 110V Dc P.T 50Va Pri 0-110V Sec 0-8-12V Auxiliary Contactor 3No 1Nc 110V Resin Cast P.T 200Vaph6.6Kv110v 3 Ph Ht Control Fuse 6.6Kv 2Amp Resin Cast Moulded Cbct 6.6Kv Epoxy Mouldd 2 Core Ct Ratio12520055 Dmc Mldd 6.6Kv Insltr Fic T G Og And Fuse Copper Terminal Bar For Og Terminal Earth Leakage Relay30ma-3A Wtime Delay Ct Oprted Ct Sec 5A Motor Prtectn Relay Ammeter 96Sq Mm Ammeter Selector Switch Voltmeter 96Sqmm Voltmeter Selector Switch Hrc Fuse Base And Carrier For Control Hrc Fuse Link For Control Push Button With Element For Start Sto Lamp Holder With Lamp On Offtrip Power Hrc Fuse Brass Cable Gland Complete Withc.I Clam Timer Electronics 3Sec To3min On Delay Intrinsically Safe Pilot Panel Complete Auto Transformer Oil Cooled Cu Wound