Bidding Tender - 20626697

Services

571029

Tender Bidding Support

We provide Tender Bidding Support for Cartage Of The Following Material From 132 Kv Taj Agra To Site Of Work Through The Kacha And Pakka Road Including The Work Of Its Loading And Unloading At The Respective Ends Including The Cost Of Arrangement Of Labour, T&P, Carrier Etc, Required For Proper Completion Of Work. Distance 00- 70 Kms. 8.5 Meter Long Pcc Pole 250 Kva Transformer 100 Kva Transformer 63/16 Kva Transformer 11 Kv 3X3003x320x3.185, 3X30 Xlpe Cable Line Material Viz, Aerial Bunch Conductor/Weasal Conductor/Dog G.I. Earth Wire, Cross Arm, Angle, Channel, Insulators, Clamps And Other Line Material As Required. Cutting Of Kharanja / Metallic Road/Concrete Portion While Digging Pit For Erection Of Pcc/Stp Poles, Stays Rod And Giving The Exact Shape After Execution Work As Per Direction Of Supervising Engineer. It Includes The Cost Of Labour, T&P, Carrier Etcreauired For Proper Completion Of Work. Erection And Grouting Of Single Pole Of 8.5 Meter Long Pcc Pole In 1:2:4 Cement Sand, And Bricks Blast, Including Fixing Of Accessories For Ht/Lt Line As Per Respo Manual And As Per Direction Of Engineer Incharge. Making Ht T-Off Connection On Existin Mains, Labour, T&P And Carrier Etc, Required For Proper Completion Of Work. Erection And Grouting Of Stays In 1:2:4 Ratio Cement Sand, And Bricks Blast As Per Respo Manual And As Per Direction Of Supervising Engineer. Fixing Of Earthing Rod As Per Respo Manual And As Per Direction Of Supervising Engineer. Laying, Sagging And Stringing And Umpiring/ Binding Etc Of The Following Conductor On The Aforesaid Newly Erected Poles As Pre Respo Manual And As Per Direction Of Supervising Engineer, Including The Cost Of Arrangement Of Labour, T&P Carrier Etc Required For Proper Completion Of Work. Acsr Weasal Conductor Removal Of Following T/F From Double/Single Pole After Opening Ht/Lt Connections And Their Carriage To 132 Kv Taj Store Agra Including Loading And Unloading At Both And. 100 Kva T/F 63 Kva T/F 25 Kva T/F/ 10 Kva T/F Construction Of Plinth Of Size 5’X6’X5’ For The Installation Of 250/400 Kva Distribution Transformers. The Size Of Plinth Shall Be Of 4’ Above The Ground Level. At The Bottom There Shall Be Brick Ballast Pad Of Size 5X6’X3” Thick In Ratio 1:3:6 Cement, Sand And Brick Ballast. The First Class Brick Wall Work Shall Be 9” Thick In Ratio 1:4 Cement And Sand. The Hollow Portion Among The Wall Shall Be Filled Up With The Brick Ballast Properly Hammered And Rammeredas Per Direction Of Supervising Engineer. On The Top Of The Well There Shall Be 12 Mm Thick Iron Rod At Distance Of 9’’ And Rcc Work In Ratio 1:3:6 Cement, Sand And Grit Stone There Shall Be Plastering All Over The Plinth 12 Mm Thick In Ratio 1:4 Cement And Sand Above The Ground Level. Proper Watering And Curing Of The Plinth Shall Be Carried Out As Per Direction Of Supervising Engineer., And Also Including The Cost Of Arrangement Of Labourer, T&P Etc Required For Proper Completion Of Work. Fencing Of 250/400 Kva T/Fs As Per Following Specifications- Fabrication Of 50X50x6 Mmsize Ms Angle Frame Of Size 900X1500 Mm, Alongwith450 Mm Long Angle For Grouting The Frame And Fixing Of 2”X1.5”, 10 Swg Welded Wire Mesh With M.S. Strip Of 24X5 Mm Size All Around The Frame And Drilling 9 Mm Holes Inside Of Frames At A Distance Of 300 Mm For Jointing Of Frame With The Help Of Bolts And Nuts Including The Cost Of All Required Material The Width Of Panal May Vary As Per Site Conditions. A- Grouting And Fixing Of Angle Iron Frames In Ratio 1:2:4 Cement Coarse Sand And Stone Ballast In The Pocket Of 150X150 Mm All Round The Plinth And Bolting Of Frames With 25X8 Mm Size Bolts And Nuts. B- Making Main Gate In Front Of The Plinth Of Size 3000X2400 Mm By Making Two Leaves Of Size 3000X1200 Mm Size And Grouting The Same In Ratio And Method Mentioned As Item B Above Fixing With Hinges With Dandles For Locking System. C- Painting Of Entire Wire Mess Angle Iron Etc, With Bus Green Super Enameled Pain To Two Coats On The Primer Two Coats Of Red Oxide Chemical Earthing Of Neutral And Body Of 250/400 Kva Power Transformers Installed At Substation, By Inserting Of 50 Mm Dia Gi Pipe Having 25 Mm Gi Chemical Filled Pipe In Between Pipe In Pipe Isi Marked B Grade Connecting With Galvanized Ms Flat Of Size 50X6 Mm With Body Of Transformers To Above Pipe In Pipe Pip And Filling Of Chemical Crystalline Conductive Mixture Containing Highly Conductive Mixture Around The Pip Up To 3 Meters Including Making Of Chamber At The Top Of Earthing Complete In All Respect As Per Following Technical Details. Earth Pipe Material Mild Steel Duly Galvanized. Main Electrode Diameter- 25 Mm. Auxiliary Electrode Pipe Diameter- 50 Mm. Wall Thickness Of Main Electrode- 02 Mm And As Per Direction Of Supervising Engineer. Installation Of Following T/F On Newly Constructed Double Pole In Proper Alignment Direction & Making Ht/Lt Connection. 250 Kva T/F 100 Kva T/F 63 Kva T/F / 16 Kva Removal Of Existing Xlpe Cable From Existing Making Bundle And Carriage The Same From Work Side To 132 Kv Taj Store Agra Including Loading And Un Loading At Both Ends. Laying Of 3X300 Sqmm 11 Kv Xlpe Cables By Making Required Loop At A Distance Of 4 Mtr. Including Excavation Of Earth One Meter Deep And Laying Brick 18 Nos In One Mtr. Local Sand Filling Over Layed Cable, As Per Respo Norms Including Proper Filling Of Earth And Leveling & Rammuring Etc, Complete Work In All Respect. Fixing/ Filling Of Heat Shrinkable Cable Boxes, Indoor And Outdoor Complete Work In All Respect.

» Get complete Support to submit Tender Bid.
» Support in Bidding Online and upload your Bids on the department Portal.
» Support in documentation and Vendor Registration.
» Checking Eligibility Criteria
» Support in Technical as well as Financial Bid.
» Tender Document.


For more details Kindly fill up the form and our executive will get in touch with you or Call us :- 08320565287.