Eligibility Criteria - 22180551

521501

Check Eligibility Criteria

Check your eligibility criteria for tender Supervisor General Shift 9:30 Am To 6:00 Pm Highly Skilled, Plumber General Shift 9:30 Am To 6:00 Pm Skilled, Carpenter General Shift 9:30 Am To 6:00 Pm Skilled, Helper General Shift 9:30 Am To 6:00 Pm Un-Skilled, Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge.Nominal Concrete 1:3:6 Or Richer Mix I/C Equivalent Design Mix, Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge.Nominal Concrete 1:4:8 Or Leaner Mix I/C Equivalent Design Mix, Demolishing R.C.C. Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge, Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Materialand Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar, Dismantling Doors, Windows And Clerestory Windows Steel Or Wood Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead : Of Area 3 Sq. Metres And Below, Dismantling Doors, Windows And Clerestory Windows Steel Or Wood Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead :Of Area Beyond 3 Sq. Metres, Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. For Thickness Of Tiles 10 Mm To 25 Mm, Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead, Dismantling Aluminium/ Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Material And Stacking Of Serviceable Material With In 50 Meters Lead As Directed By Engineer-In-Charge., Dismantling Precast Concrete Or Stone Slabs In Walls, Partition Walls Etc. Including Stacking Within 50 Metres Lead : Thickness Above 40 Mm Up To 75 Mm, Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:3:6 1 Cement : 3 Coarse Sand Zone-Iii Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources, Reinforced Cement Concrete Work In Walls Any Thickness, Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3 1 Cement : 1.5 Coarse Sandzone-Iii Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources, Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform, Brick Work With Common Burnt Clay F.P.S. Non Modular Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In :Cement Mortar 1:4 1 Cement : 4 Coarse Sand, Brick Work With Common Burnt Clay F.P.S. Non Modular Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In :Cement Mortar 1:6 1 Cement : 6 Coarse Sand, Half Brick Masonry With Common Burnt Clay F.P.S. Non Modular Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level.Cement Mortar 1:3 1 Cement :3 Coarse Sand, Half Brick Masonry With Common Burnt Clay F.P.S. Non Modular Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level.Cement Mortar 1:4 1 Cement :4 Coarse Sand, Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry., Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately.Second Class Teak Wood, Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 Part I Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws, Providing And Fixing Wooden Moulded Beading To Door And Window Frames With Iron Screws, Plugs And Priming Coat On Unexposed Surface Etc. Complete :50 X 20 Mm, Providing And Fixing Aluminium Extruded Section Body Tubular Type Universal Hydraulic Door Closer Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm, With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete, Providing And Laying Vitrified Floor Tiles In Different Sizes Thickness To Be Specified By The Manufacturer With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 1 Cement : 4 Coarse Sand, Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 800X800 Mm, Providing And Laying Vitrified Tiles In Floor With Different Sizes Thickness To Be Specified By The Manufacturer, With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive Water Based Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints Payment For Grouting Of Joints To Be Made Separately.Size Of Tile 600X600 Mm, Providing And Laying Vitrified Tiles In Different Sizes Thickness To Be Specified By The Manufacturer, With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Brand & Manufacturer, In All Colours And Shade, In Skirting, Riser Of Steps, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive Water Based Conforming To Is: 15477, In Average 6 Mm Thickness, Including Grouting Of Joints Payment For Grouting Of Joints To Be Made Separately.Size Of Tile 600X600 Mm . French Spirit Polishing :Two Or More Coats On New Works Including A Coat Of Wood Filler, Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 1 Cement : 4 Coarse Sand, Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels.Area Of Slab Over 0.50 Sqm. Extra For Fixing Marble /Granite Stone, Over And Above Corresponding Basic Item, In Facia And Drops Of Width Upto 150 Mm With Epoxy Resin Based Adhesive, Including Cleaning Etc. Complete, Extra For Providing Opening Of Required Size & Shape For Wash Basin/ Kitchen Sink In Kitchen Platform, Vanity Counter And Similar Location In Marble/ Granite/ Stone Work, Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete By Using Labout Component Mentioned In Part A Excluding Rate Of Labour Component, Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete.With Twin Rubber Stoper, Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/Sqm Both Side Inclusive As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre.For Complete Item Descritption Please Refer Annexure 2 Of Specification Document Of Boq, Providing And Fixing Partition Upto Ceiling Height Consisting Of G.I. Frame And Required Board, Including Providing And Fixing Of Frame Work Made Of Special Section Power Pressed/ Roll Form G.I. Sheet With Zinc Coating Of 120 Gms/Sqmboth Side Inclusive, Consisting Of Floor And Ceiling Channel 50Mm Wide Having Equal Flanges Of 32 Mm And 0.50 Mm Thick, Fixed To The Floor And Ceiling At The Spacing Of 610 Mm Centre To Centre With Dash Fastener Of 12.5 Mm Dia Meter 50 Mm Length Or Suitable Anchor Fastener Or Metal Screws With Nylon Plugs And The Studs 48 Mm Wide Having One Flange Of 34 Mm And Other Flange 36 Mm And 0.50 Mm Thick Fixed Vertically Within Flanges Of Floor And Ceiling Channel And Placed At A Spacing Of610 Mm Centre To Centre By 6 Mm Dia Bolts And Nuts, Including Fixing Of Studs Along Both Ends Of Partition Fixed Flush To Wall With Suitable Anchor Fastener Or Metal Screws With Nylon Plugs At Spacing Of 450 Mm Centre To Centre, And Fixing Of Boards To Both Side Of Frame Work By 25 Mm Long Dry Wall Screws On Studs, Floor And Ceiling Channels At The Spacing Of 300 Mm Centre To Centre. The Boards Are To Be Fixed To The Frame Work With Joints Staggered To Avoid Through Cracks, M.S. Fixing Channel Of 99 Mm Width 0.9 Mm Thick Having Two Flanges Of 9.5 Mm Each To Be Provided At The Horizontal Joints Of Two Boards, Fixed To The Studs Using Metal To Metal Flat Head Screws, Including Jointing And Finishing To A Flush Finish With Recommended Jointing Compound, Jointing Tape, Angle Beads At Corners 25 Mm X 25 Mm X 0.5 Mm, Joint Finisher And Two Coats Of Primer Suitable For Board As Per Manufactures Specification And Direction Of Engineer In Charge All Complete.75 Mm Overall Thickness Partition With 12.5 Mm Thick Double Skin Fire Rated Glass Reinforced Gypsum Grg Plaster Board Conforming To Is: 2095: Part 3 Board With Bis Certification Marks, Providing And Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Is : 15622 Thickness To Be Specified By The Manufacturer Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 1 Cement: 3 Coarse Sand And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete . 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Finished With A Floating Coat Of Neat Cement Of Mix :1:3 1 Cement: 3 Fine Sand, Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. . Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface :Water Thinnable Cement Primer, Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade :Two Or More Coats On New Work, Repairs To Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Area 2.5 Sq.Meters And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In-Charge.With Cement Mortar 1:4 1Cement: 4 Coarse Sand, Providing And Fixing Stainless Steel A Isi 304 18/8 Kitchen Sink As Per Is:13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required :Kitchen Sink Without Drain Board 610X510 Mm Bowl Depth 200 Mm, Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms.15 Mm Nominal Bore Jaquar Make, Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 :15Mm Nominal Bore Jaquar Make, Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. Glazing, Paneling And Dash Fasteners To Be Paid For Separately :Anodised Aluminium Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15, Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. Glazing, Paneling And Dash Fasteners To Be Paid For Separately :Polyester Powder Coated Aluminium Minimum Thickness Of Polyester Powder Coating 50 Micron, For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required Fittings Shall Be Paid For Separatelypolyester Powder Coated Aluminium Minimum Thickness Of Polyester Powder Coating 50 Micron, Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is: 12823 Grade L Type Ll, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge. Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side, Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item:With Float Glass Panes Of 5 Mm Thickness Weight Not Less Than 12.50 Kg/Sqm, Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors, Including Cost Of Cutting Floors, Embedding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer-Incharge.With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness, Providing And Fixing Anodised Aluminium Grill Anodised Transparent Or Dyed To Required Shade According To Is: 1868 With Minimum Anodic Coating Of Grade Ac 15 Of Approved Design/Pattern, With Approved Standard Section And Fixed To The Existing Window Frame With C.P. Brass/ Stainless Steel Screws @ 200 Mm Centre To Centre, Including Cutting The Grill To Proper Opening Size For Fixing And Operation Of Handles And Fixing Approved Anodised Aluminium Standard Section Around The Opening, All Complete As Per Requirement And Direction Of Engineer-In-Charge. Only Weight Of Grill To Be Measured For Payment., Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved., Providing And Fixing At All Height Wall Panelling With Phenol Bonded Bamboo Mat Board Conforming To Is:13958-1994 Including Providing And Fixing To Frame Work Made Of 50Mm X 50Mm Hardwood Plugs Including Cutting Brick Work And Fixing In Cement Mortar And Making Good The Wall Etc. And Also Providing And Fixing Wooden Moulded Corner Beading Of Triangular Shape To The Junction Of Panelling Etc. With Iron Screws All Complete As Per Direction Of Engineer-In-Charge. 12Mm Thickness, Extra For Brick Work / Aac Block Masonry / Tile Brick Masonry In Superstructure Above Floor V Level, For Each Four Floors Or Part Thereof By Mechanical Means., Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More., Extra For R.C.C./ B.M.C/ R.M.C. Work Above Floor V Level For Each Four Floors Or Part Thereof., Extra For Half Brick Masonry In Superstructure, Above Floor V Level For Every Four Floors Or Part Thereof By Mechanical Means., Extra For Concrete Work In Superstructure Above Floor V Level For Each Four Floors Or Part Thereof, Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls Any Thickness Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Sunken Floor Etc., Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering And Finishing: 1:2:4 1 Cement : 2 Coarse Sand Zone-Iii Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources, Providing And Fixing Frame Work For Partitions/ Wall Lining Etc. Made Of 50X50x1.6 Mm Hollow Ms Tube, Placed Along The Walls, Ceiling And Floor In A Grid Pattern With Spacing @ 60 Cm Centre To Centre Both Ways Vertically & Horizontally Or At Required Spacing Near Opening, With Necessary Welding At Junctions And Fixing The Frame To Wall/ Ceiling/ Floors With Steel Dash Fasteners Of 8 Mm Dia, 75 Mm Long Bolt, Including Making Provision For Opening For Doors, Windows, Electrical Conduits, Switch Boards Etc., Including Providing With Two Coats Of Approved Steel Primer Etc. Complete, All As Per Direction Of Engineerin-Charge, Providing Wood Work In Frames Of False Ceiling, Partitions Etc. Sawn And Fixed In Position With Necessary Stainless Steel Screws Etc. Kiln Seasoned And Chemically Treated Hollock Wood, Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes, Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws.Second Class Teak Wood 35Mm, Extra For Providing Heavy Sheet Float Glass Panes Instead Of Ordinary Float Glass In Glazed Doors, Windows And Clerestory Window Shutters. Area Of Opening For Glass Panes Excluding Portion Inside Rebate Shall Be Measured 5.0 Mm Thick Instead Of 4 Mm Thick, Providing And Fixing Is : 12817 Marked Stainless Steel Butt Hinges Heavy Weight With Stainless Steel Screws Etc. Complete : 100X60x2.50 Mm, Providing And Fixing Isi Marked Aluminium Butt Hinges Anodised Anodic Coating Not Less Than Grade Ac 10 As Per Is: 1868 Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete: 100X63x3.2 Mm, Providing Anf Fixing Brass Door Handle 450 Mm, Providing And Fixing Isi Marked Oxidised M.S. Sliding Door Bolts With Nuts And Screws Etc. Complete :300X16 Mm, Providing And Fixing Isi Marked Oxidised M.S. Sliding Door Bolts With Nuts And Screws Etc. Complete :250X16 Mm, Providing And Fixing Isi Marked Oxidised M.S. Tower Bolt Black Finish, Barrel Type With Necessary Screws Etc. Complete :250X10 Mm, Providing And Fixing Isi Marked Oxidised M.S. Tower Bolt Black Finish, Barrel Type With Necessary Screws Etc. Complete :300X10 Mm, Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868, Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete :250X16 Mm, Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868, Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete :300X16 Mm, Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete :200X10mm, Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete :150X10mm, Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete :100X10mm, Providing And Fixing Carbon Steel Galvanised Minimum Coating 5 Micron Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade Yield Strength 480 N/Mm2, Counter Sunk Head, Comprising Of 10 Mm Dia Polyamide Pa 6 Grade Sleeve, Including Drilling Of Hole In Frame, Concrete/ Masonry, Etc. As Per Direction Of Engineer-In-Charge.10X120 Mm, Providing And Fixing Carbon Steel Galvanised Minimum Coating 5 Micron Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade Yield Strength 480 N/Mm2, Counter Sunk Head, Comprising Of 10 Mm Dia Polyamide Pa 6 Grade Sleeve, Including Drilling Of Hole In Frame, Concrete/ Masonry, Etc. As Per Direction Of Engineer-In-Charge. 10X140 Mm, Providing And Laying Vitrified Tiles In Floor With Different Sizes Thickness To Be Specified By The Manufacturer, With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive Water Based Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints Payment For Grouting Of Joints To Be Made Separately.Size Of Tile 800X800 Mm, Providing And Laying Vitrified Tiles In Different Sizes Thickness To Be Specified By The Manufacturer, With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Brand & Manufacturer, In All Colours And Shade, In Skirting, Riser Of Steps, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive Water Based Conforming To Is: 15477, In Average 6 Mm Thickness, Including Grouting Of Joints Payment For Grouting Of Joints To Be Made Separately.Size Of Tile 800X800 Mm, Providing And Fixing Thermal Insulation With Resin Bonded Fibre Glass Wool Conforming To Is: 8183 Having Density 24 Kg/M3, 50 Mm Thick, Wrapped In 200G Virgin Polythene Bags Fixed To Wall With Screw, Rawel Plug & Washers And Held In Position By Criss Crossing Gi Wire Etc. Complete As Per Directions Of Engineer-In-Charge., Providing And Fixing 12 Mm Thick Frameless Toughened Glass Door Shutter Of Approved Brand And Manufacture, Including Providing And Fixing Top & Bottom Pivot & Double Acting Hydraulic Floor Spring Type Fixing Arrangement And Making Necessary Holes Etc. For Fixing Required Door Fittings, All Complete As Per Direction Of Engineer-In-Charge Door Handle, Lock And Stopper Etc.To Be Paid Separately., Providing And Fixing 1Mm Thick M.S. Sheet Door With Frame Of 40X40x6 Mm Angle Iron And 3 Mm M.S. Gusset Plates At The Junctions And Corners, All Necessary Fittings Complete, Including Applying A Priming Coat Of Approved Steel Primer.Using Flats 30X6mm For Diagonal Braces And Central Cross Piece, Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix Of 0.70 Kg Of Organic Coated Filler Of Desired Shade 0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg, Including Filling / Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge. Size Of Tile 600X600 Mm, Providing Corrugated G.S. Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required.1.00 Mm Thick With Zinc Coating Not Less Than 275 Gm/M², Providing And Fixing Double Scaffolding System Cup Lock Type On The Exterior Side, Up To Seven Story Height Made With 40 Mm Dia M.S. Tube 1.5 M Centre To Centre, Horizontal & Vertical Tubes Joining With Cup & Lock System With M.S. Tubes, M.S. Tube Challies, M.S. Clamps And M.S. Staircase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For The Required Duration As Approved And Removing It There After .The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connection With The Building Etc Wherever Required For Inspection Of Work At Required Locations With Essential Safety Features For The Workmen Etc. Complete As Per Directions And Approval Of Engineer-In-Charge .The Elevational Area Of The Scaffolding Shall Be Measured For Payment Purpose .The Payment Will Be Made Once Irrespective Of Duration Of Scaffolding. Note: - This Item To Be Used For Maintenance Work Judicially, Necessary Deduction For Scaffolding In The Existing Item To Be Done, Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete.40 Mm Dia By Using Labout Component Mentioned In Part A. Excluding Rate Of Labour Component, Providing And Fixing Chlorinated Polyvinyl Chloride Cpvc Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. Concealed Work, Including Cutting Chases And Making Good The Walls Etc.20 Mm Nominal Dia Pipes By Using Labout Component Mentioned In Part A. Excluding Rate Of Labour Component, Making Chases Up To 7.5X7.5 Cm In Walls Including Making Good And Finishing With Matching Surface After Housing G.I. Pipe Etc, Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, I Single Socketed Pipes.75 Mm Diameter By Using Labout Component Mentioned In Part A. Excluding Rate Of Labour Component, Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, I Single Socketed Pipes. 110 Mm Dia By Using Labout Component Mentioned In Part A. Excluding Rate Of Labour Component, Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture, Structural Steel Work In Single Section, Fixed With Or Without Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete., Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete, Steel Work In Built Up Tubular Round, Square Or Rectangular Hollow Tubes Etc. Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes, Providing And Fixing Brass 100Mm Mortice Latch And Lock With 6 Levers Without Pair Of Handles Best Make Of Approved Quality For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete, Providig And Fixing 12Mm Thick Fire Rated Gypsum Board On Already Available Ms & Aluminium Frame As Per Direction Of Engineer-In -Charge, Providing And Fixing Gl Frame Upto Ceiling Height, Providing And Fixing 12Mm Thick Fire Rated Gypsum Board On Single Face Of Gl Framing Including Gl Framing As Per Direction Of Engineer-In -Charge, Providing And Fixing 300Mm Size Stainsteel Door Ha Ndle As Per Direction Of Eic, Providing And Fixing S.S. Sliding Door Bolt With Nut And Screw Etc Complete As Per Direction Of Elc, Providing And Fixing Stainless Steel Tower Bolts Lsl Marked, With Necessary Screws Etc.Complete As Per Direction Of Elc, Providing And Fixing 200Mm Size Aluminium Door Handle As Per Direction Of Engineer In Charge, Providing And Fixing C.P. Brass Stop Cock Concealed Of Standard Design And Of Approved Make Conforming To Is:8931.15 Mm Nominal Bore Jaquar Make By Using Labout Component Mentioned In Part A Excluding Rate Of Labour Component, Providing And Fixing 12 Mm Commercial Ply And 6 Mm Mdf Board Over 12 Mm Commercial Ply On Existinb Gl Frame Partition Wall And Making Opening For Electrlcal Fitting, / Ac Duct Opening And Other Audio & Vedio Fixture As Per Requirement And Direction Of Elc, Providing And Fixing 12 Mm Mdf Board Over Existing 6 Mm Mdf Exiting Board In Partition Wall And Making Design Of Pannel Size 1100X430mmtypical By Cutting Mdf Board And Fixing Wooden Beeding Of Size 17Mmx12mm All Around Pannel Including Making Opening For Electrical Fitting, / Ac Duct And Other Audio & Vedio Fixture Opening As Per Requirement And Direction Of Elc, Providing And Fixing White Vitreous China Wash Basin Including Making All Connections But Excluding The Cost Of Fittings : Flat Back Wash Basin Of Size 630X450 Mm Jaquar Make By Using Labout Component Mentioned In Part A Excluding Rate Of Labour Component. . Flat Back Wash Basin Of Size 590X420 Mm As Per Eic Jaquar Make By Using Labout Component Mentioned In Part A Excluding Rate Of Labour Component, Providing And Fixing Ptmt Bottle Trap For Wash Basin And Sink. Bottle Trap 31Mm Single Piece Moulded With Height Of 270 Mm, Effective Length Of Tail Pipe 260 Mm From The Centre Of The Waste Coupling, 77 Mm Breadth With 25 Mm Minimum Water Seal, Weighing Not Less Than 260 Gms Jaquar Make By Using Labout Component Mentioned In Part A. Excluding Rate Of Labour Component, Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Gra

» Get complete Support to submit Tender Bid.
» Support in Bidding Online and upload your Bids on the department Portal.
» Support in documentation and Vendor Registration.
» Checking Eligibility Criteria
» Support in Technical as well as Financial Bid.
» Tender Document.


For more details Kindly fill up the form and our executive will get in touch with you or Call us :- 08320565287.