GeM Registration - 20526652

Services

551615

GeM Registration

GeM Registration for tender Supply Of Different Materials - 11 Kv Link Set Post Type Heavy Duty. Suitable For 400-630 Amp Current Capacity. Is: 9920 Part-I To Iv 11 Kv Air Break Switch With Pipe & Handle Complete 3 Phase, 600 Amp Is: 9920 Part-I To Iv 11 Kv Drop Out Fuse Set 3 Phase 400A Is:9385 Part-I To Iii As Amended Upto Date Gapless Surge Arrestor, 9 Kv, 10 Kv, La With Polymer/Porcelain Housing, Stn. Type Is: 3070 Part-3 11 Kv Pin Insulator With Pins 12 Kn. Is:731 And Is:3188 Lt Shackle Insulators With Mukki Clamps 16 Kn Of Standard Make Galvanised Nuts And Bolts Of Sizes. 6”, 7”, 8”, 9”, 11”, 12”X1/2” Dia Half Thread. G.I Wire 8 Swg. Guy Wire 7/14 Swg. Guy Rods With Turn Buckle 5’ Long Complete 11 Kv Tension Disc/Suspension Disc Is:731 And Is:3188 Fabricated Gi Channel, X-Arms Of Sizes 75X40x6 Mm 50X50x6mm And 100X50x6 Mm. Fabricated Gi Angle, 50X50x6mm Al. Solderless Clamps Suitable For Transformer1000 Kva As Per Relevant Is Al. Solderless Clamps Suitable For Transformer630 Kva As Per Relevant Is Al. Solderless Clamps Suitable For Transformer400/500 Kva As Per Relevant Is Al. Solderless Clamps Suitable For Transformer250 Kva As Per Relevant Is Al. Solderless Clamps Suitable For Transformer100 Kva As Per Relevant Is Al. Solderless Clamps Suitable For Transformer63 Kva As Per Relevant Is Aluminium Thimbles 630 Mm2 As Per Relevant Is Aluminium Thimbles 500 Mm2 As Per Relevant Is Aluminium Thimbles 400 Mm2 As Per Relevant Is Aluminium Thimbles 300 Mm2 As Per Relevant Is Aluminium Thimbles 240 Mm2 As Per Relevant Is Aluminium Thimbles 185 Mm2 As Per Relevant Is Aluminium Thimbles 120 Mm2 As Per Relevant Is Aluminium Thimbles 95 Mm2 As Per Relevant Is Aluminium Thimbles 70 Mm2 As Per Relevant Is Aluminium Thimbles 35 Mm2 As Per Relevant Is Aluminium Thimbles 25 Mm2 As Per Relevant Is Aluminium Thimbles 16 Mm2 As Per Relevant Is 35 Mm Sq, 11 Kv Aerial Bunched Cable 3 Core + Earth, Xlpe As Per Is 7098 Part 2 Ammneded Upto Date Polycab/Havells/Paramount/Gloster 50 Mm Sq, 11 Kv Aerial Bunched Cable 3 Core + Earth, Xlpe As Per Is 7098 Part 2 Ammneded Upto Date Polycab/Havells/Paramount/Gloster 70 Mm Sq, 11 Kv Aerial Bunched Cable 3 Core + Earth, Xlpe As Per Is 7098 Part 2 Ammneded Upto Date Polycab/Havells/Paramount/Gloster 95 Mm Sq, 11 Kv Aerial Bunched Cable 3 Core + Earth, Xlpe As Per Is 7098 Part 2 Ammneded Upto Date Polycab/Havells/Paramount/Gloster 120 Mm Sq, 11 Kv Aerial Bunched Cable 3 Core + Earth, Xlpe As Per Is 7098 Part 2 Ammneded Upto Date Polycab/Havells/Paramount/Gloster 16 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type Is 7098 Ammended Upto Date Polycab/Havells/Paramount/Gloster 25 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type Is 7098 Ammended Upto Date Polycab/Havells/Paramount/Gloster 50 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type Is 7098 Ammended Upto Date Polycab/Havells/Paramount/Gloster 185 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type Is 7098 Ammended Upto Date Polycab/Havells/Paramount/Gloster 240 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type Is 7098 Ammended Upto Date Polycab/Havells/Paramount/Gloster 300 Mm2 Single Core Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type Is 7098 Ammended Upto Date Polycab/Havells/Paramount/Gloster 400 Mm2 Single Core Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type Is 7098 Ammended Upto Date Polycab/Havells/Paramount/Gloster 630 Mm2 Single Core Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type Is 7098 Ammended Upto Date Polycab/Havells/Paramount/Gloster 25 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type Is 7098 Ammended Upto Date Polycab/Havells/Paramount/Gloster 35 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type Is 7098 Ammended Upto Date Polycab/Havells/Paramount/Gloster 50 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type Is 7098 Ammended Upto Date Polycab/Havells/Paramount/Gloster 185 Mm2 3.5 Core Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type Is 7098 Ammended Upto Date Polycab/Havells/Paramount/Gloster 240 Mm2 3.5 Core Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type Is 7098 Ammended Upto Date Polycab/Havells/Paramount/Gloster 300 Mm2 3.5 Core Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type Is 7098 Ammended Upto Date Polycab/Havells/Paramount/Gloster 400 Mm2 3.5 Core Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type Is 7098 Ammended Upto Date Polycab/Havells/Paramount/Gloster 630 Mm2 3.5 Core Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type Is 7098 Ammended Upto Date Polycab/Havells/Paramount/Gloster Galvanized Earthing Strips 50Mm X3mm. Bobin Insulators Clamps/Cliffs. Back Clamp Collars/Pole Collars G.I. Galvanized Abc Cable Hooks Aluminum Paint Asian/Nerolac/Berger Make. Red Oxide Paint Asian/Nerolac/Berger Make. 11 Kv Heat Shrinkable Outdoor Cable Termination Kit 11 Kv Heat Shrinkable Outdoor Cable Jointing Kit 11 Mtr. Is 2713 540 Sp 56Steel Tubular Poles 9 Mtr. Is 2713 540 Sp 33Steel Tubular Poles 8 Mtr. Is 2713 540 Sp 15Steel Tubular Poles 30Mm2 Acsr Conductor Is: 398Part-Ii Ammended Upto Date 50Mm2 Acsr Conductor Is: 398Part-Ii Ammended Upto Date 100Mm2 Acsr Conductor Is: 398Part-Ii Ammended Upto Date 630 Amp 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal 0.8 In-1.0 In . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka Ics Icu 100%, With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanismrom. The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage Ue 690V, Insulation Voltage Ui 1000V, And Impulse Withstand Voltage Uimp 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time <10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens 400 Amp 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal 0.8 In-1.0 In . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka Ics Icu 100%, With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanismrom. The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage Ue 690V, Insulation Voltage Ui 1000V, And Impulse Withstand Voltage Uimp 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time <10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens 200 Amp 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal 0.8 In-1.0 In . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka Ics Icu 100%, With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanismrom. The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage Ue 690V, Insulation Voltage Ui 1000V, And Impulse Withstand Voltage Uimp 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time <10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens 160 Amp 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal 0.8 In-1.0 In . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka Ics Icu 100%, With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanismrom. The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage Ue 690V, Insulation Voltage Ui 1000V, And Impulse Withstand Voltage Uimp 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time <10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens 100 Amp 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal 0.8 In-1.0 In . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka Ics Icu 100%, With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanismrom. The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage Ue 690V, Insulation Voltage Ui 1000V, And Impulse Withstand Voltage Uimp 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time <10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens 40 Amp 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal 0.8 In-1.0 In . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka Ics Icu 100%, With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanismrom. The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage Ue 690V, Insulation Voltage Ui 1000V, And Impulse Withstand Voltage Uimp 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time <10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens Rubber Gloves Passed As Per Standard Is 4770 Ammended Upto Date And Working Potential Of 11 Kv Rubber Shoes Sole Insulation Is 4770 Ammended Upto Date And Working Potential Of 11 Kv 20 Feet Long, 11 Kv Discharge Rod Set Each Set Containing 3 No Rods, Copper Electrode, Manufactured From Fibre Reinforced Plastic Material, Having Hv Test Of 110 Kv, Push Button Locking Sytem, Crocodile Grounding Clamp, Rubber Clading To Hold, Die Cast Alu. Earthing Instrument For 30Mm Diameter With 4 Sq Mm Copper Cable 8 Mtrs; Top Section Diameter > 25 Mm And Bottom Section Diameter >45 Mm With Earthing Spike Of Standard Make Battery Operated 11-33 Kv Voltage Detector Cpri Tested Complete Kit Including Hv Detector Probe, 20 Feet Frp Insulation Stick, Carrying Bag. The Detector Should Have Audio As Well As Visual Anunciation, Sensing Distance Of 1 Meter For 11Kv And 3 Meters For 33Kv. Bright High Intensity Red Leds For Visual Annunciation Even In Unfavourable Daylight Conditions And A Buzzer To Produce Loud Beep Audible Even In Noisy Backgrounds Natural Latex 11Kv Rubber Gloves Type-2 Is 4770; Isi Mark With Test Voltage > 17000 V And Working Voltage Of 11000 With Maximum Leakage Current At Tets Voltage Of 14Ma Rms Isi Mark And Is Conformation On Each Glove White Color Industrial Safety Helmets Is 2925 With Chin-Strap And Nape-Strap With Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance As Per Is 2925 Isi Mark And Is Conformation On Each Helmet Yellow Color Industrial Safety Helmets Is 2925 With Chin-Strap And Nape-Strap With Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance As Per Is 2925 Isi Mark And Is Conformation On Each Helmet Safety Belt With Static And Dynamic Loading Completely As Per Is 3521 Isi Mark And Is Conformation On Each Belt Uk Size 6 And Below Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 Isi Mark And Is Conformation On Each Shoe Uk Size 7 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 Isi Mark And Is Conformation On Each Shoe Uk Size 8 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 Isi Mark And Is Conformation On Each Shoe Uk Size 9 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 Isi Mark And Is Conformation On Each Shoe Uk Size 10 And Above Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 Isi Mark And Is Conformation On Each Shoe 12 Piece Tool Kit 1-Piece Screwdriver, 1-Piece Hammer, 7-Pieces Screwdriver Bits, 1-Piece Plier, 1-Piece Wrenchadjustib And 1-Piece Measuring Tape Bosch/Dewalt/Taparia Clamp Meter, Conforms To Iec 61010, Cat Ii 600V Safety Rated, 600A Ac Current Measurement, Ac/Dc Voltage, Resistance, Continuity & Data Hold Function, 2 Years Manufacturer Warranty Fluke/Digi Sense/ Motwane/Extech 18 Feet Fiber Link Rod 18 Feet Bamboo Link Rod Wooden Ladder A Class Budloo Finished Length Of 17 3 By 1.5 ; Finished Step 2 By 1.5 ; Bottom Width 18; Step To Step Distance 13 Alongwith Ms Straps On Both Side Of Each Step 16 Mm² Cable 2C From Lt Line To Meter, 1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type Is 1554 Part 1 Ammended Upto Date Polycab/Havells/Paramount/Or Equivalent 25 Mm² Cable 2C From Lt Line To Meter, 1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type Is 1554 Part 1 Ammended Upto Date Polycab/Havells/Paramount/Or Equivalent For Upkeep And Maintenance Of Distribution System For The Year 2021-22.

» Get complete Support to submit Tender Bid.
» Support in Bidding Online and upload your Bids on the department Portal.
» Support in documentation and Vendor Registration.
» Checking Eligibility Criteria
» Support in Technical as well as Financial Bid.
» Tender Document.

GeM Registration Process
image

Services for GeM
image

Required Document for GeM
image


For more details Kindly fill up the form and our executive will get in touch with you or Call us :- 08320565287.