Insulator Tenders

(Select any tender from the list to send an email)
Ref. No #31637506 Central Government/Public Sector Live

Supply of Lightening Arrestor Supply Of Metal Oxide Lightning Arresterla Heavy Duty Station Class Metal Oxide Gapless Lightning Arrester Morester Type Stn-D Type Heavy Duty Station Class Metal Oxide Gaples S Lightning Arrester Morester Type Stn-D Reference Standard Iec 99-4 Of 2006/Is 3070 Part3 1993 No Of Unit One Rated Voltage 30Kv Nominal Discharge Current With Class 10Ka Class 1 Reference Current 2 Ma Pea K Reference Voltage Greater Than Rated Arrester Voltage At Reference Leakage Current At Cov Less Than 0.8 Ma M Ax Continuos Operating Voltage 24Kv Rms Maximum Residual Voltage For Discharge Current Of 8/20 Micro Sec Wav E 5000 Amps 85Kvpeak 10000 Amps 90Kvpeak 20000 Amps 100Kvpeak Max Steep Front Residual Voltage At 10 Ka With One Micro Sec Rise Time 100Kvpeak Max Switching Impulse Residual Voltage With 40/80 Us Wave At 1000 A Mps 80Kvpeak Energy Dissipation Capability Form 3 Seqential Shots 6 Kj /Kv High Current 4/10 Us Test Value 100Ka Peak Long Duration Current Tests Current Peak Virtual Duration As Per Discharge Class 2 Of Iec -99-4 Table -4 200 0 Micro Sec Pressure Relief Class Class A Short Circuit Current Capability 40Ka Rms Partial Discharge At 1.05 Time S Mcov Less Than 10Pc 0.1 Second 34.5Ka Rms 0.1 Second 33.5Ka Rms 10.0 Second 31.5Ka Rmsinsulation Withst And Tests On Arrester Housing One Minute 50 Hz Dry & Wet 95Ka Rms Lightning Impulse Voltage Withstand 175Ka R Ms Creepage Distance Mm 900 Nominal Weight Of Complete Unit 11?10% Kgs Height Of Complete Unit From Bas E To The Line Side Refer Drg No 2500300 Minimum Recommended Contre To Centre Spacing Between Arresters500 Mm Clearance Required Form Ground Equipment At Various Heights Of Arrester 400 Mm Earthing Arrangement Pro Vided For Earthing Side Of Arrester Ground Terminal Bracket Provided For Connecting Earth Strip Drg No 6220151 M Ounting Flange Dimensional Details End Casting 3 Holes 11Mm 120 Deg Apart At 165Mm Pcd Rated Frequency 50 Hz ? 5% Insulation Material Porcelani Specific Creepage Distance 25Mm/Kv Altitude Above Sea Level 1000/ Mtrs. From Msl Minimum Humidity 85% Markings 99-4 Of 2006/Is 3070 Part3 1993 Earthing Switch Operating M Echanism Independent Manual Drive, Mechanically Interlocked With Main Blades Attached As Per Annexure-A Warranty Period: 12 Months After The Date Of Delivery

Location
Rajasthan
Due Date
14 May, 2024
Amount
Refer Document
Ref. No #31641011 Central Government/Public Sector Live   GeM Tender

Supply of 11 Kv Polymeric Pin Insulator Q3 11 Kv Polymeric Post Insulator Q3 11 Kv Polymeric Disc Insulator Q3

Location
Jharkhand
Due Date
27 Apr, 2024
Amount
Refer Document
Ref. No #31634534 Corporations/Associations/Others Live

Supply Of Material -P.P Reel Insulator -Must Be Of Virgin Plastic Material. Polypropylene Or Equivalent With Break Down Voltage Of 15 Kv, Strain Insulator-Must Of Poly Polypropylene Plastic Rated For 15Kv Uv Stabilized, Corner Post Gi- 8 Ft., Gi-2, 14 Guage Thickness, Painted Having Diametrically Opposite Holes Of Size 6 Mm At Required Interval Of Fencing Installation, Intermediate Post T Angle Post 8 Feet Painted 25Mmx25mmx3mm Having Holes Of Size 6 Mm At Required Intervels Of Fencing Instllation, Supporting Post 6 Feet Gi 1 Inch 14 Guage Thickness Painted, Stay T Angle 2 Feet Painted 25 Mmx25mm X 3Mm, 12 Swg Ht Wire 12 Guage 2.5 Mm Dia High Tensile Wire With Sink Coating For Use As Conducting Wire Winding Strain Insulator, 14 Swg Binding Wire-High Quality Zinc Coating Wire For Binding Reel Insulators, Tighing Support Post With Corner Post, Wire Tightner-Permanant Wire Tighter Made Of Special Aluminium Alloy Designed For Kv, Uv Stabilized, Joint Clamp With Nut And Bolt- Supply Of Joint Clamp With Nuts And Bolt Gi Galavanized Coating For Fastening Conducting Wire Around Posts, Hot Dipped Galvanised , Earth Rod-Copper Plated Earth Rod 14 Mm -3 Ft. Length, Earthing Compound 8 Kg, Tension Spring Spring Steel Cable Of Making Compresion Loads, Galvanised 15Cm Length, Withstand 400Kg , Gate Handle-Steel Rope With Handle And Spring Assembly. Handle Made Of Polyethylene, Lead Out Cable For Fence System Double Insulated Gi Cable Inner Core Wire 2 Sq.Mm. Hot Dipped Galvanised Steel Core, Capable Of With, Standing 15Kv Should Be Provided To Prevent Bimetal Salt Formation At Connections, Single Core 2.5 Mm Sq. Cable-2.5 Mm² Single Core Copper Cable For Connecting The Solar Panel To The Tubular Battery Through Charge Control Unit With Required Terminal Sockets, Nut And Bolt, Washer, Lightining Diverter -15Kv-50Kv Rod Gap Arrester, Must Be Capable Of Diverting Stray Lightning And Adjustable For Spark Gaps Adequate Earthing To Be Provided, 100 Watt Solar Panel- 100 Watt/ 12 Volt And Above Poly Crystalline With 10 Year Warranty Having Iec/Mnre Certification, Charge Control Unit-20 A 12/24 V Pwm Charge Controller Unit Of Standard Make Suitable To Control The Charging Of The Tubular Battery Energizer With 10 Kv Output Safety Standards To Be Followed Are Bis 302-2-76 Iec60335-2-76. Switch-High, Medium And Low Power Setting. Fence Alarm System Covering Area Of 1.5 Km, Solar Panel Supporting Stand With Metal Box Painted For Battery And Energiser - 18 Guage Thickness Metal Boxlockable - Painted. Gi-Sheet, Painted Should Be Capable Of Housing Batterry, Charge Controller And Energizer And Fixed With Required Clamps And Nut And Bolt On Solar Panel Support Stand Made Of Gi Pipe Of 50Mm Diameter And B Class Type With Suitable Arrangement For Holding The Panel Warning Sign-Polyethylene Plastic With Satuatory Warning With Sign, Tubular Battery 12 V, 100Ah- 12 V, 100 Ah C10 Rating With Full 5 Year Replacement Warranty Tower Battery For Energising The Energiser, Digital Volt Meter- Must Display Fence Voltage Digitally Upto 15Kv . Made Of Non Shocking Plastic, Tool Kit Consisting Of Wire Tighterner Rod, Double Headed Spanner, High Tensile Wire Cutter And Cutting Plier For Installation Of New 5 Line Solar Power Fence

Location
Kerala
Due Date
29 Apr, 2024
Amount
7.58 Lacs
Ref. No #31635842 Corporations/Associations/Others Live   GeM Tender

Supply Of Thermal Insulation, Metal False Ceiling, Epoxy Flooring, 75 Mm Height Epoxy Coving, Expansion Joint By Rasin And Hardener, Earth Work In Excavation, Pcc 1 4 8, Rcc 1 1 5 3, Mild Steel Tmt Bar Fe 500 D Or More, Demolishing Cement Concrete Work Manually Or Mechanical Means, Demolishing Brick Work Manually Or Mechanical Means, Structural Steel Work Riverted Bolted Or Welded Detail Specification As Per Annexure A, Synthetic Enamel Paint, Precoated Galvanised Iron Profile Sheet Point Five Mm Thick, Precoated Galvanised Steel Profile Sheet Point Five Mm Thick Gutter 600 Mm Over All Grith, Plinth Protection 50 Mm Cc 1 3 6 And 75 Mm Thick Lean Concrete Detail Specification As Per Annexure A, Dismantling Of Old Plaster Detail Specification As Per Annexure A, 12 Mm Thick Cement Plaster 1 Is To 4 Detail Specification As Per Annexure A, Removing Dry Or Oil Bound Distemper Detail Specification As Per Annexure A, Pointing Work Detail Specification As Per Annexure A, Acrylic Smooth Exterior Paint Old Work Detail Specification As Per Annexure A, White Cement Based Putty Detail Specification As Per Annexure A, Distempering With 1St Quality Acrylic Detail Specification As Per Annexure A, 150 Mm Rain Water Pvc Pipe Detail Specification As Per Annexure A, Aluminium Partition Fixed Portion Powder Coated Aluminium Detail Specification As Per Annexure A, Aluminium Door Window Powder Coated Aluminium Detail Specification As Per Annexure A, Manual Sliding Device With Rail And Wheel Detail Specification As Per Annexure A, Aluminium Door Fitting 200 Mm Long Door Handle Detail Specification As Per Annexure A, Godrej And Equivalent Lock Detail Specification As Per Annexure A, Aluminium Door Fitting Tower Bolt 300X10 Mm Detail Specification As Per Annexure A, Glazing 8 Mm Thick Plain Glass With Epdm Rubber Detail Specification As Per Annexure A, 12 Mm Thick Prelaminated Partical Board Detail Specification As Per Annexure A, Making Joint Free And Hole By Butyl Adhesive Tape Detail Specification As Per Annexure A, Led 36 Watts Input False Light Of 600 X600 Mm Light And Wiring Detail Specification As Per Annexure A, Fixing Acp Curtain Wall For Duct And False Ceiling With Base Frame Detail Specification As Per Annexure A, 50 Mm Thick Sandwich Puf Panel With Both Point Five Mm Thick Sheet Both,

Location
Uttar Pradesh
Due Date
06 May, 2024
Amount
88.94 Lacs