Supply Of Spares -1.5 Sq.Mm Of Single Core Multi Strand Fr-Lsh Pvc Insulated Industrial Grade Copper Conductor Unsheathed Flexible Cables, 1100 Volt Conforming To Is 694., 2.5 Sqmm. Single Core Multi Strand Fr-Lsh Pvc Insulated Industrial Grade Copper Conductor Unsheathed Flexible Cables, 1100 Volt Conforming To Is 694., 4.0 Sqmm. Single Core Multi Strand Fr-Lsh Pvc Insulated Industrial Grade Copper Conductor Unsheathed Flexible Cables, 1100 Volt Conforming To Is 694 ., 3Cx1.5 Sq.Mm Frls Pvc Insulated And Pvc Sheathed, Multicore, Multi Strand Annealed Bare Copper Conductor Flexible Industrial Cable For Voltage Grade 1100 Volt, Conforming To Is 694. , 3Cx2.5 Sq.Mm Frls Pvc Insulated And Pvc Sheathed, Multicore, Multi Strand Annealed Bare Copper Conductor Flexible Industrial Cable For Voltage Grade 1100 Volt, Conforming To Is 694 . , 3Cx4 Sq.Mm Frls Pvc Insulated And Pvc Sheathed, Multicore, Multi Strand Annealed Bare Copper Conductor Flexible Industrial Cable For Voltage Grade 1100 Volt, Conforming To Is 694 . , 6A To 32A Rating, 240/415V, 10Ka, C Curve Miniature Circuit Breaker Suitable For Inductive Load Of Single Pole In The Existing Mcb Db As Required., 6A To 32A Rating, 240/415V, 10Ka, C Curve Miniature Circuit Breaker Suitable For Inductive Load Of Double Pole Suitable For Existing Mcb Db As Required., 6A To 32A Rating, 240/415V, 10Ka, C Curve Miniature Circuit Breaker Suitable For Inductive Load Of Triple Pole Suitable For The Existing Mcb Db As Required., 6A To 32A Rating, 240/415V, 10Ka, C Curve Miniature Circuit Breaker Suitable For Inductive Load Of Triple Pole And Neutral Suitable For The Existing Mcb Db As Required., 40A Rating, Four Pole, 415V, 50Hz Isolator Suitable For The Existing Mcb Db As Required., 63A Rating, Four Pole, 415V, 50Hz Isolator Suitable For The Existing Mcb Db As Required., 25A Rating, Double Pole Single Phase And Neutral, 240V Residual Current Circuit Breaker Rccb Having A Sensitivity Current 30Ma Suitable For The Existing Mcb Db As Required., 40A Rating, Double Pole Single Phase And Neutral, 240V Residual Current Circuit Breaker Rccb Having A Sensitivity Current 30Ma Suitable For The Existing Mcb Db As Required., 63A Rating, Double Pole Single Phase And Neutral, 240V Residual Current Circuit Breaker Rccb Having A Sensitivity Current 30Ma Suitable For The Existing Mcb Db As Required., Suitable Size Gi Box With Modular Plate And Cover Including Providing 1 No.3 Pin 5/6A Modular Socket Outlet And 1 No. 5/6A Modular Switch Etc. Complete As Required., Suitable Size Gi Box With Modular Plate And Cover Including Providing 1 No.6 Pin 5/6A & 15/16A Modular Socket Outlet And 1 No. 15/16A Modular Switch Etc. Complete As Required., Heavy Duty Pvc Casing Capping- Casing Bearing Isi Mark Of Size- 20Mmx12mm, Heavy Duty Pvc Casing Capping- Casing Bearing Isi Mark Of Size- 25Mmx16mm, 5/6 Amp Switch Modular Type Switch/Socket For The Existing Modular Plate & Switch Box Etc. Complete As Required., 15/16 Amp Switch Modular Type Switch/Socket For The Existing Modular Plate & Switch Box Etc. Complete As Required., 3 Pin 5/6 Amp Socket Outlet Modular Type Switch/Socket For The Existing Modular Plate & Switch Box Etc. Complete As Required., 6 Pin 15/16 Amp Socket Outlet Modular Type Switch/Socket For The Existing Modular Plate & Switch Box Etc. Complete As Required., Call Bell Suitable For Single Phase, 230V Complete As Required At Site., 2X2 Feet 36 W Led Light Fixture Recess Type Suitable For Operation On Single Phase 230V, 50Hz Power Supply Complete As Required As Per Enclosed Technical Specification ., 3- Pin, 5/6 Amp Isi Marked Plug Top Suitable For Operation On Single Phase 230V, 50Hz Power Supply., 3- Pin, 15/16 Amp Isi Marked Plug Top Suitable For Operation On Single Phase 230V, 50Hz Power Supply., Red Outer Lens For Rwy End Light Suitable For Existing Airfield Ground Lighting System Agl Complete As Required . Existing Light Fixture Is Of Vardhman Make, Green Outer Lens For Rwy Threshold Light Suitable For Existing Airfield Ground Lighting System Agl Complete As Required . Existing Light Fixture Is Of Vardhman Make, Yellow Filter For Runway Edge Light Suitable For Existing Airfield Ground Lighting System Agl Complete As Required . Existing Light Fixture Is Of Vardhman Make, 5 Kv Grade Plug & Receptacle Type-I Suitable For Single Core 6 Sqmm Airfield Cable Complete As Required ., 150W, 6.6/6.6A Halogen Lamp Pk30d64361 Hlx-Z, Make -Osram Or Equivalent Suitable For Existing Agl/ Cat-I Fittings Complete As Required ., 200W, 6.6/6.6A Halogen Lamp Pk30d64382 Hlx-C Make - Osram Or Equivalent Suitable For Existing Agl/ Cat-I Fittings Complete As Required ., Isolating Transformer Of 15 Watts, 6.6A/6.6A, 5Kv, 50Hz Suitable For Existing Agl/Cat-I Light Fixtures Complete As Required, Isolating Transformer Of 45 Watts, 6.6A/6.6A, 5Kv, 50Hz Suitable For Existing Agl/Cat-I Light Fixtures Complete As Required, Isolating Transformer Of 100 Watts, 6.6A/6.6A, 5Kv, 50 Hz Suitable For Existing Agl/Cat-I Light Fixtures Complete As Required, Isolating Transformer Of 150 Watts, 6.6A/6.6A, 5Kv, 50 Hz, Suitable For Existing Agl/Cat-I Light Fixtures Complete As Required, Isolating Transformer Of 200 Watts, 6.6A/6.6A, 5Kv, 50 Hz Suitable For Existing Agl/Cat-I Light Fixtures Complete As Required, Beacon Lamp Of 1000W Par64 Ffp 120Vac Or Equivalent Suitable For Existing Becon Light Fixture Complete As Required., Cable Jointing Kit For 1X6 Sqmm Afl Cable Complete As Required ., Hrc High Speed Fuse-Semi Conductor Protection Fuse-Bs88 Type, 100Fe, 100A Rating, Voltage 690Vac, Breaking Capacity 200 Ka Suitable For Existing Switch Gear Make-Bussmann Series Eaton Or Equivalent For Electrical And Agl And Cat I Lighting System
Supply of Half Overlap Polyimide Covered Copper Conductor For 4601Az Armature Coil Bare Conductor Nominal Size 3.8+/- 0.05Mm W X 1.1+/- 0.03Mm T X 0.4 +/-0.1Mm Radius At Corners Maximum Covered Size 4.025 X 1.325 Mm. Material As Per Specification No.4Tms.095.002 Rev-0. Warranty Period: 30 Months After The Date Of Delivery
Supply of Screened 5 Pair 10 Core Color Coded & Twisted Data Communication Cable, Each Core Made Of Copper Conductor Of 0.50Mm Diameter7/0.20Mm Abc Annealed Bare Copper & Polyethylene Insula Ted Having Core Outer Diameter 1.3Mm Wall Thickness 0.25Mm, Such 2 Core Twisted In A Pair And Such 5 Pair Laid Up & Polyester Taped, 0.6 Mm Atc Annealed Tinned Copper Drain Wire, Overlapped With Aluminium Foil For Scr Eening/Shielded, Polyester Tape, Grey Color Pvc Outer Sheath Of Wall Thickness 1.3Mm Should Be Provided For The Data Communication Wherever Required. Tolerance In Dimensions Should Be Within Plus/Minus 10.
Supply Of Electrical Spares - Pvc Insulated Single Core Unsheathed Copper Flexible Wire, 1.1 Kv Grade Pvc Insulated Frls Round Sheathed Multi Core Bright Annealed Bare Copper Conductor, Incandescent Lamp 100 Watt, Incandescent Lamp 200 Watt, Electrolytic Capacitor Of 2.5 Micro F, Universal Type Starter, Penta Piano Type 6 A Switch Of 1 Way, Penta 6A, 2-In 1 Pin Socket, Penta Power Switch Of 1 Way, 20 A, Universal Socket, Combined Unit With Box Of Two Fixing Hole, 2-In-1 Switchsocket Combined With Box, Electronic Step Type Fan Regulator, Batten Holder, 6A Angle Holder, 3 Pin Plug Top Polycarbonate, 6 A, 3 Pin Plug Top Polycarbonate, 16 A, Modular Type Switch And Socket, Insulation Taperoll Of 1.8 Cm X 7.5 Mtr, Pvc Switch Board Boxes, Pvc Modular Surface Switch Board Boxes, Casing -Caping, Upvc Conduit Pipe, Led Indication Lamps, Plastic Enclosure Distribution Board, Mcb, Wire Stripping Pliers, Screw Driver, Pedastal Fan, Wall Mount Fan, Rawal Plug, Wood Screw, Panel Door Lock, Pad Lock, Drill Machine Set, Tool Bags, 2X2 Led Panel Light, Led Recess Down Light, Led Street Light Fitting, Led Flood Light Fitting, Tubular Type Batteries, Vrla Type Batteries, Smc Junction Boxes, Smc Multi Meter Boxes, Closing Coil, Under Voltage Coil, Digital Ammeter, 6201 Fan Bearings, 6202 Fan Bearings
Work Of Replacing Bare Conductor With Lt Ab Cable