Ref. No #31634534 Corporations/Associations/Others Live

Supply Of Material -P.P Reel Insulator -Must Be Of Virgin Plastic Material. Polypropylene Or Equivalent With Break Down Voltage Of 15 Kv, Strain Insulator-Must Of Poly Polypropylene Plastic Rated For 15Kv Uv Stabilized, Corner Post Gi- 8 Ft., Gi-2, 14 Guage Thickness, Painted Having Diametrically Opposite Holes Of Size 6 Mm At Required Interval Of Fencing Installation, Intermediate Post T Angle Post 8 Feet Painted 25Mmx25mmx3mm Having Holes Of Size 6 Mm At Required Intervels Of Fencing Instllation, Supporting Post 6 Feet Gi 1 Inch 14 Guage Thickness Painted, Stay T Angle 2 Feet Painted 25 Mmx25mm X 3Mm, 12 Swg Ht Wire 12 Guage 2.5 Mm Dia High Tensile Wire With Sink Coating For Use As Conducting Wire Winding Strain Insulator, 14 Swg Binding Wire-High Quality Zinc Coating Wire For Binding Reel Insulators, Tighing Support Post With Corner Post, Wire Tightner-Permanant Wire Tighter Made Of Special Aluminium Alloy Designed For Kv, Uv Stabilized, Joint Clamp With Nut And Bolt- Supply Of Joint Clamp With Nuts And Bolt Gi Galavanized Coating For Fastening Conducting Wire Around Posts, Hot Dipped Galvanised , Earth Rod-Copper Plated Earth Rod 14 Mm -3 Ft. Length, Earthing Compound 8 Kg, Tension Spring Spring Steel Cable Of Making Compresion Loads, Galvanised 15Cm Length, Withstand 400Kg , Gate Handle-Steel Rope With Handle And Spring Assembly. Handle Made Of Polyethylene, Lead Out Cable For Fence System Double Insulated Gi Cable Inner Core Wire 2 Sq.Mm. Hot Dipped Galvanised Steel Core, Capable Of With, Standing 15Kv Should Be Provided To Prevent Bimetal Salt Formation At Connections, Single Core 2.5 Mm Sq. Cable-2.5 Mm² Single Core Copper Cable For Connecting The Solar Panel To The Tubular Through Charge Control Unit With Required Terminal Sockets, Nut And Bolt, Washer, Lightining Diverter -15Kv-50Kv Rod Gap Arrester, Must Be Capable Of Diverting Stray Lightning And Adjustable For Spark Gaps Adequate Earthing To Be Provided, 100 Watt Solar Panel- 100 Watt/ 12 Volt And Above Poly Crystalline With 10 Year Warranty Having Iec/Mnre Certification, Charge Control Unit-20 A 12/24 V Pwm Charge Controller Unit Of Standard Make Suitable To Control The Of The Tubular Energizer With 10 Kv Output Safety Standards To Be Followed Are Bis 302-2-76 Iec60335-2-76. Switch-High, Medium And Low Power Setting. Fence Alarm System Covering Area Of 1.5 Km, Solar Panel Supporting Stand With Metal Box Painted For And Energiser - 18 Guage Thickness Metal Boxlockable - Painted. Gi-Sheet, Painted Should Be Capable Of Housing Batterry, Charge Controller And Energizer And Fixed With Required Clamps And Nut And Bolt On Solar Panel Support Stand Made Of Gi Pipe Of 50Mm Diameter And B Class Type With Suitable Arrangement For Holding The Panel Warning Sign-Polyethylene Plastic With Satuatory Warning With Sign, Tubular 12 V, 100Ah- 12 V, 100 Ah C10 Rating With Full 5 Year Replacement Warranty Tower For Energising The Energiser, Digital Volt Meter- Must Display Fence Voltage Digitally Upto 15Kv . Made Of Non Shocking Plastic, Tool Kit Consisting Of Wire Tighterner Rod, Double Headed Spanner, High Tensile Wire Cutter And Cutting Plier For Installation Of New 5 Line Solar Power Fence

Location
Kerala
Due Date
29 Apr, 2024
Amount
7.58 Lacs
Ref. No #31629118 Central Government/Public Sector Live

Supply of 415 Volts Ac Pre-Cooling Cum 110V. Dc Box Shall Be Fabricated With Ms Sheet 3Mm Thick And Ms Angle Of Size 40X40x5 Mm. The Box Shall Be Out Door Type, Floor Mounted Weather, Dus T & Vermin Proof With Degree Of Protection Ip54. It Shall Be Divided Into Two Compartments Of Equal Size Whi Ch Shall Have Independently Hinged Doors For Both The Compartments Lockable And Double Earthing Terminal Proper Canopy Shall Be Provided On The Top To Prevent Rain Water Entering Inside The Box. Separate Detach Able Plate 3Mm Thick Ms Sheet For Both Compartment Shall Be Provided 100 Mm Dia. Hole With Groomet For Incoming And Outgoing Cable. Incoming & Out Going Cable Shall Be Connected With The Bus-Bar From Bottom Side. The Box Shall Be Finished With Powder Coating Of Approved Colour Thickness Not Less Than 40 Microns. A1st Compartment Shall Be Suitable For Accommodating 1 No. 100 A. 4 Pole Mccb Fixed Type Thermal Mag Netic Release 35 Ka Breaking Capacity And Conforming To Is:13947/Part-2 & Iec: 60947/2, One 63A 5Pin 3P+ N+E415 V. Panel Mounted Socket With Spring Locked Cover & One 63A. 5 Pin 3P+N+E 415 V. Plug Conformi Ng To Iec 309/1&2, One No.16A.3Pin2p+E 250 V. Panel Mounted Socket With Spring Locked Cover & 1No. 16A 3 Pin2p+E 250 V. Plug Conforming To Iec 309/1&2 And 200A. Aluminium Bus-Bar For Phases & Neutral Shoul D Be Fixed On Fiber Sheet With Pvc Sleeve Colour Coded. 2Nd - Compartment Shall Be Suitable For Accommo Dating 1 No. 32 A. Dc Series Mcb Dp Suitable For 130 V Dc Supply, One No. Panel Mounted 32A 3 Pin 2P+E Socket With Spring Locked Cover A One No. 32A 3 Pin 2P+E Plug Conforming To Iec 309/1&2 And 200A. Alum Inium Bus-Bar For Two Positive & One Negative Should Be Fixed On Fiber Sheet With Pvc Sleeve Colour Code D. B Mccb & Mcb Should Be Operated Without Opening The Front Cover Inter- Connection With Suitable Siz E Pvc Insulated Copper Conductor Cable Conforming To Is:694/1990 From Bus Bar To Mccb/Mcb To Socket. 3 Core & 4 Core Pvc Insu- Lated And Pvc Sheathed Copper Conductor Flexible Cable Up To 110 V-Shall Be Co Nfirmed To Is:694 With Plugs. Proper Visible Indication Plate Fluorescent Screen Printed On The Front Of Both C Ompartments Shall Be Provided For 415V. Ac Pre-Cooling Box And 110V Dc Box As Approved By Railway. Cthe Box Shall Be Grouted In Ground With Cement Morter Mixing 1:2:4 With Muffing As Per Rail Way Drawing. Note:- It Should Be Ensured: 1 All Cable Connections To Be Db S J.Box Panel Etc. Should Be M Ade Through Proper Size Of Cable Glands/End Fittings No Space Should Be Left Open To Avoid Entry Of Insect S/Lizards Etc. If Necessary, Blanking Plate Should Be Provided In Dbj. 2 Flexible/Rigid Conduits Wherever Provi Ded Should Be With Suitable End Fittings/Clamps Conduit Should Be Secured On Surface Through Suitable Clamps At Regular Interval As Per Is Spec. 3 Sitc As Per Attached Drawing. Warranty Period: 30 Months After The Date O F Delivery

Location
Uttar Pradesh
Due Date
07 May, 2024
Amount
Refer Document
Ref. No #31594959 Central Government/Public Sector Live   GeM Tender

Supply of D C Rectifier And Rectifier Q3

Location
Karnataka
Due Date
25 Apr, 2024