Supply of Nozzle O2 Oxygen Part No 120384 Of Hyperthermusa To Suit Hypertherm Head Torch Part No 020970 Of Under Water Cnc Plasma Cutting Machine Model No Pho Enix Dp 5000. Make: Hypertherm Usa Or Koreatec With Leading Parameter. Specification: 1 Minimum O2 Inlet Pressure Remains At One Setting Of 120Psi 8.2 Bar For All Material Thickness. 2 Minimum N 2 Inlet Pressure Remains At One Setting Of 150Psi 10.3 Bar For All Material Thickness. 3 O2 Flow Rate At Full Scale I S 127 Scfh 60L/Min @ 120Psi 8.2 Bar Inlet Pressure. 4 N2 Flow Rate At Full Scale Is 374 Scfh 176L/Min @ 150Ps I 10.3 Bar Inlet Pressure. 5 Water Chiller Pump Outlet Pressure Remains Between 175-185 Psi 12-12.8 Bar For All Material Thickness. 6 Set Initial Torch Height Before Piercing To Approximately Twice The Torch Standoff Distance F Or The Material You Are Cutting. Warranty Period: 30 Months After The Date Of Delivery
Certain Repair/ Maint/ Improvement To E/M Installation, Cooling Towers, Ahus, Chiller/ Condensor Units, Condensor/ Chiller Pumpsets/ Pipeline, Valves And Repair To Central Ac Plants At Bhadoriya Under Gesouth
Supply of 1 Rotary Evaporator With Vacuum Pump And Chiller Q3
Supply of Calibration Of Pressure Gauges 696 Calibration Of Pressure Gauge Residential Building Calibration Of Pressure Gauge Opd Ipd Residential Pump Room Calibration Of Pressure Gauge Stp Etp Calibration Of Pressure Gauge Acedemic Building Ipd Opd Calibration Of Pressure Gauge Ipd Opd Chiller Plant
Planning, Designing, Construction, Testing And Commissioning Of Commercial Building Of Rcc Framed Structure Basement 2 + Gf + 6 Floors+ Terrace “Pm Ekta Mall” At Pandri Haat Campus, Pandri, Raipurchhattisgarh Which Meet Green Building Norms And Obtain The Certification Of The Same By Incorporating Stipulated Specification Along With All Services Civil And E&M As Per Nbc- 2016/Cpwd/Cgpwd Specification, Including Site Survey, Soil Investigation, Provision Of Parking Planning And Design Of Required Services, Preparation Of Preliminary Architectural & Detailed Working Drawings, Structural Analysis & Design, Planning, Designing, Execution Of All Civil And E & M Services, Obtaining All Statutory Approvals Including Dismantling Of Existing Building, Cutting/Transplant Of Trees, Environment Clearance/Environment Impact Assessment Eia And Commencement Certificate From Local Body And Commissioning Of Services Etc. As Per Detailed Scope And Specifications For Civil And E & M Works Including Internal Water Supply & Sanitary Installations, Internal Electrical Installations And Fans, External Civil And Electrical Service Connections, Power Wiring, Telephone Conduiting And Wiring, Lightning Conductor System, Lifts, Escalators, Addressable Intelligent Fire Alarm System, Fire Fighting System With Wet Riser And Sprinkler System & Pressurized Mechanical Ventilation I/C Chiller, Illuminated Signage, Lan System, Ip Based Epabx System, Wifi System, Ip Based Cctv System, Façade Lighting, Façade Projection Mapping, Water Supply Pump Sets, Dewatering Pumps And Panels, Online Ups System With 30 Minutes Backup, Dg Set, Integrated Building Management System, Audio -Visual/Conference System, Auditorium, Solar Water Heating System, Compound And Street Lighting With Led, Stp, Horticulture Work Etc And Any Other Component Necessary For Completion, Making The Facilities Functional, Obtaining Fire Clearance, Water Connection, Electrical Connection And Lift From Authorities Concerned, Obtaining Occupancy Certificate/ Building Use Bu Permission From Local Body, Obtaining Green Certification, Preparation And Submission Of “As Built Drawings” And Handing Over Of The Building All Complete As Per Directions Of Engineer-In-Charge Including 1 Year Of Operation And Maintenance & 3 Years Of Defect Liability Period.