Supply of Tank Cleaning Skid Mud Pump With Flp Motor Flp Exhaust Fan 24 Inch Dia Rrl Type B Hose 15 Mtr Nil
Maintenance Of Equipment - Aluminum Checker Platefor Two Semi Trailer 5Mm, Aluminum Cheq Rebate, Air Suspension Bladdar, Diaphragm Assembly, Obsolete Suspension System 200Mm, Break Boosters, Pneumatic Valves, Palm Coupling, Hoses And Fittings, Tool Box, Spare Wheel Carriers, Lifting Ropes, Spare Wheel Rim, Pneumatic Brake And Suspension Line For Two Semi Trailer, Retro Reflective Sticker, Shelter Cabinet Twist Lock, Mounting Plate, Bushes, Bolts And Nuts, Air Tanks, Electrical Lines And Accessories For Two Semi Trailer, Tail Lamp Assembly, 7 Pin Sockets, Side Marking Lights, Air Compressor For Industrial Ac, Circuit Breaker Relay Contactor For Industrial Ac, Paint White, Paint Black, Silicon, Primer, Thinner, Cleaning Brush, Detergent, Grease, Painting Denting And Repair Charges, Cutting Welding, All Wheels Overhauling Axle Lack Greasing And Repairing, Fitment Of Air Suspension Systems, Maintenance Of Three Ac, Fitting Of Electrical Line, Any Other Costs Of Items Or Job
Annual Operation And Maintenance Contract For E And M Installations At Shravasti Airport, Periodical Maintenance And Operation Of Electrical And Mechanical Installations Involving Operation, Repairs And Maintenance, Attending To Complaints/Faults/ Breakdowns And Taking Rectification Action, Ensuring Serviceability/ Satisfactory Working Condition Of The Systems, Carrying-Out Preventive Maintenance, Maintenance Of Records/ Documents Etc Under This Contract For Shift Duty For All 7 Days On All Working Days Including Saturdays, Sundays And Holidays As Per Tender Specifications, Terms & Conditions By Providing/Engaging Of Electrician & Helper. Shift Purpose- Electrician Skilled- 03 No. Per Day For Shift Duty For All 7 Days In A Week. Helper Un-Skilled- 03 No. Per Day For Shift Duty For All 7 Days In A Week., Monthly Visit Of Fire Technician/Engineer Form Oem Of Fda System Or From Oem Authorized Dealer For Carrying Out Healthiness Check Of Fda System, Attending Faults, Carrying Out Preventive Maintenance I/C Cleaning Etc. As Required To Fire Main Panel And Repeater Panels, Detectors, Response Indicators, Mcp Of The Fda System Etc. Making Replacement Of The Spare Parts/Accessories Etc. If Required For Healthiness Of The Fda System And Submission Of Service Report To Eic. Charges Against Labour & Tools Etc. Required For Attending Faults, Preventive Maintenance, Servicing, Replacement/Installations Of Spare Parts And Accessories Are Included In The Item. All Spare Parts/Accessories Required For Healthiness Of Fda System Shall Be Provided By Aai I.E Paid To The Agency Against Supply Of Materials As In Extra Item On Market Rate On Submission Of Original Invoice And Supporting Documents/Price List Of Oem. Inventory Of Fda System- Main Control Panel & Microprocessor Based Analog Addressable - 01 No. Addressable Multi Detector - 60 Nos Addressable Heat Detector - 4 Nos Ri - 39 Nos Mcp - 3 Nos Addressabel Hooter- 4 Nos Fault Isolator- 4 Nos, Maintenance & Up-Keeping Of Fire Extinguishers, Fire Suppression System And Fire Fighting System Installed At Shravasti Airport Inclusive Of Periodical Checking/ Testing, Servicing, Maintaining Records, Attending Break Down Calls Of All Fire Extinguishers, Hydrant Valves, Hoze Boxes, Pipes, Branch Pipes, Hose Reels, Hose Pipes, Sprinklers, Nrvs, Pipe Lines, Pressure Switches, Main Pumps, Jockey Pumps, Booster Pump, Batteries, Starter Panels, Pressure Gauges, Sluice Valves/Gate Valve Etc As Detailed In The Special Conditions Of The Contract, Particular Specification Etc. Complete As Required. Note- This Item Is Only Service And Does Not Cover Material Part. All Spare Parts/Accessories Required For Healthiness Of Fire Fighting System Shall Be Provided By Aai I.E Paid To The Agency Against Supply Of Materials/Repair Of Equipment As In Extra Item On Market Rate On Submission Of Original Invoice And Supporting Documents/Price List Of Oem., Etc
Supply of Swimming Pool Equipments, 328 Leaf Net Wall And Floor Cleaning Brush Gown Swimming Costume Cap Floter Or Kicker Pull Buoy Flippers Towel Pool Lane Divider Safety Swimming Pool Stick Or Hook Foot Mat For Swimming Pool Rubber Octagonal Roll Mat Swimming Tube Hose Pipe For Cleaning Purpose Rope Nylon 32 Mm
Replacement Of T 22 Burner High Pressure, Replacement Of M 22 Burner High Pressure, Replacement Of Rv Burner High Pressure, Replacement Of Chapati Plate With Burner, Replacement Of Adaptor Click On, Replacement Of Copper Pipe 1 5 Ft, Replacement Of Copper Pipe 2 Ft, Replacement Of Copper Pipe 3 Ft, Replacement Of Flexible Braided Pipe Cpt 2 Ft, Replacement Of Flexible Braided Pipe 3 Ft Cpt, Replacement Of Flexible Braided Brass Nut 6 Ft Bpt, Replacement Of Flexible Braided Brass Nut 9 Ft Bpt, Suraksha Hose Brass Nut, 2 Burner Stove S S Body, Mcv Main Control Valve, Ncv Brass Needle Control Valve, Spanner Size 17, Teplontape, Neoprine Washer, Single Burner With Control Valve, T 22 M 22 Ventury, H P Main Line Regulator, Canteen Burner Tube Single, Low Pressure Regulators, T 22 Assembly, Rv Assembly Brass, M22 Brass Socket Assembly 22 Mm, Domestic Stove Cleaning Servicing, Domestic Stove On Off Knob, Domestic Stove Nosel, Domestic Stove Gas Cock, Domestic Stove Lock Pin, T 35 Burner High Pressure, T 35 Brass Chamber Assembly, M 35 Burner High Pressure, M 35 Brass Chamber Assembly, Onsite Servicing Charges Cleaning Servicing, Visit Charges