Supply of Set Of Sealing And Fixing Rubber For Compartment Doors To Drawing No Cc 56415 Alt Nil And Drawing No Cc 56416 Alt Nil, In Running Length 2510 Mm Each For Lhb Coaches. Warranty Period: 30 Months After The Date Of Delivery
Supply of Set Of Spares For Compartment Door Locking Arrangement For Three Phase Emu Conventional Rake1 Push To Close Latchleft- Make: South Co, Cat No: R4-99-483-20 01No2 Push To Close Latchright- Ma Ke: South Co, Cat No: R4-99-483-10 01No Or Equivalent Warranty Period: 30 Months After The Date Of Delivery Item 1: Lock Assembly R5 Draw Latch Concealed-Heavy Duty With Fixing Screws And Accessories / A Ctuator Knob R5-99-156 Of M/S Southco Or Equivalent M/S Dirak As Per Drg.No- Icf/Mrvc/C/Bt-5-8-002 Item No.13 Warranty Period: 30 Months After The Date Of Delivery
Supply of Set Of Sealing And Fixing Rubber For Lhb Coaches Compartment Doors To Drawing No. Cc56415, Alt. Nil & Cc56416, Alt. Nil In Running Length 2510Mm Each. Warrant Y Period: 30 Months After The Date Of Delivery
Supply of Frp Profile For Ac Compartment Door, Length 865 Mm For Lhb Ac 2Tier Coa Ches, As Per Drawing: Mi007915 Alt Nil, Packing Instruction No. Pi023 Ver1.0 . Packing Instruction: Items Should Be Individually Wrapped With Paper And Collectively Packed In Card Bo Ard Box Having Sufficient Strength, Further Tied With Suitable Nylon Strips. A List S Hould Be Pasted On Each Box Showing Purchase Order No., Pl No., Description, Drg / Spec No, Qty, Firm Name & Address, Date Of Dispatch Etc. Warranty Period: 84 Months After T He Date Of Delivery
Repair/Replacement On Condition Basis Of Old Sbc Doors, Locks, Sealing Of Ht Compartment And Cleaning Work In Lhb Ac Coaches.
Supply of 415 Volts Ac Pre-Cooling Cum 110V. Dc Battery Charging Box Shall Be Fabricated With Ms Sheet 3Mm Thick And Ms Angle Of Size 40X40x5 Mm. The Box Shall Be Out Door Type, Floor Mounted Weather, Dus T & Vermin Proof With Degree Of Protection Ip54. It Shall Be Divided Into Two Compartments Of Equal Size Whi Ch Shall Have Independently Hinged Doors For Both The Compartments Lockable And Double Earthing Terminal Proper Canopy Shall Be Provided On The Top To Prevent Rain Water Entering Inside The Box. Separate Detach Able Plate 3Mm Thick Ms Sheet For Both Compartment Shall Be Provided 100 Mm Dia. Hole With Groomet For Incoming And Outgoing Cable. Incoming & Out Going Cable Shall Be Connected With The Bus-Bar From Bottom Side. The Box Shall Be Finished With Powder Coating Of Approved Colour Thickness Not Less Than 40 Microns. A1st Compartment Shall Be Suitable For Accommodating 1 No. 100 A. 4 Pole Mccb Fixed Type Thermal Mag Netic Release 35 Ka Breaking Capacity And Conforming To Is:13947/Part-2 & Iec: 60947/2, One 63A 5Pin 3P+ N+E415 V. Panel Mounted Socket With Spring Locked Cover & One 63A. 5 Pin 3P+N+E 415 V. Plug Conformi Ng To Iec 309/1&2, One No.16A.3Pin2p+E 250 V. Panel Mounted Socket With Spring Locked Cover & 1No. 16A 3 Pin2p+E 250 V. Plug Conforming To Iec 309/1&2 And 200A. Aluminium Bus-Bar For Phases & Neutral Shoul D Be Fixed On Fiber Sheet With Pvc Sleeve Colour Coded. 2Nd - Compartment Shall Be Suitable For Accommo Dating 1 No. 32 A. Dc Series Mcb Dp Suitable For 130 V Dc Supply, One No. Panel Mounted 32A 3 Pin 2P+E Socket With Spring Locked Cover A One No. 32A 3 Pin 2P+E Plug Conforming To Iec 309/1&2 And 200A. Alum Inium Bus-Bar For Two Positive & One Negative Should Be Fixed On Fiber Sheet With Pvc Sleeve Colour Code D. B Mccb & Mcb Should Be Operated Without Opening The Front Cover Inter- Connection With Suitable Siz E Pvc Insulated Copper Conductor Cable Conforming To Is:694/1990 From Bus Bar To Mccb/Mcb To Socket. 3 Core & 4 Core Pvc Insu- Lated And Pvc Sheathed Copper Conductor Flexible Cable Up To 110 V-Shall Be Co Nfirmed To Is:694 With Plugs. Proper Visible Indication Plate Fluorescent Screen Printed On The Front Of Both C Ompartments Shall Be Provided For 415V. Ac Pre-Cooling Box And 110V Dc Battery Charging Box As Approved By Railway. Cthe Box Shall Be Grouted In Ground With Cement Morter Mixing 1:2:4 With Muffing As Per Rail Way Drawing. Note:- It Should Be Ensured: 1 All Cable Connections To Be Db S J.Box Panel Etc. Should Be M Ade Through Proper Size Of Cable Glands/End Fittings No Space Should Be Left Open To Avoid Entry Of Insect S/Lizards Etc. If Necessary, Blanking Plate Should Be Provided In Dbj. 2 Flexible/Rigid Conduits Wherever Provi Ded Should Be With Suitable End Fittings/Clamps Conduit Should Be Secured On Surface Through Suitable Clamps At Regular Interval As Per Is Spec. 3 Sitc As Per Attached Drawing. Warranty Period: 30 Months After The Date O F Delivery
Supply of Set Of Cage Clamp Terminals For Doorway For Hybrid Non Ac Coaches. As P Er Drg.No. Cc72070, Alt-C, Of M/S Wago Or Equivalent Rcf. Packing Instruction - Spi208 Warranty Period: 3 0 Months After The Date Of Delivery Set Of Cage Clamp Terminals For Compartment For Hybrid Non Ac Coache S. As Per Drg.No. Cc72069 Alt-D. Packing Instruction - Spi208 Warranty Period: 30 Months After The Date Of Delivery