Door Spring Tenders

(Select any tender from the list to send an email)
Ref. No #31629118 Central Government/Public Sector Live

Supply of 415 Volts Ac Pre-Cooling Cum 110V. Dc Battery Charging Box Shall Be Fabricated With Ms Sheet 3Mm Thick And Ms Angle Of Size 40X40x5 Mm. The Box Shall Be Out Type, Floor Mounted Weather, Dus T & Vermin Proof With Degree Of Protection Ip54. It Shall Be Divided Into Two Compartments Of Equal Size Whi Ch Shall Have Independently Hinged s For Both The Compartments Lockable And Double Earthing Terminal Proper Canopy Shall Be Provided On The Top To Prevent Rain Water Entering Inside The Box. Separate Detach Able Plate 3Mm Thick Ms Sheet For Both Compartment Shall Be Provided 100 Mm Dia. Hole With Groomet For Incoming And Outgoing Cable. Incoming & Out Going Cable Shall Be Connected With The Bus-Bar From Bottom Side. The Box Shall Be Finished With Powder Coating Of Approved Colour Thickness Not Less Than 40 Microns. A1st Compartment Shall Be Suitable For Accommodating 1 No. 100 A. 4 Pole Mccb Fixed Type Thermal Mag Netic Release 35 Ka Breaking Capacity And Conforming To Is:13947/Part-2 & Iec: 60947/2, One 63A 5Pin 3P+ N+E415 V. Panel Mounted Socket With Locked Cover & One 63A. 5 Pin 3P+N+E 415 V. Plug Conformi Ng To Iec 309/1&2, One No.16A.3Pin2p+E 250 V. Panel Mounted Socket With Locked Cover & 1No. 16A 3 Pin2p+E 250 V. Plug Conforming To Iec 309/1&2 And 200A. Aluminium Bus-Bar For Phases & Neutral Shoul D Be Fixed On Fiber Sheet With Pvc Sleeve Colour Coded. 2Nd - Compartment Shall Be Suitable For Accommo Dating 1 No. 32 A. Dc Series Mcb Dp Suitable For 130 V Dc Supply, One No. Panel Mounted 32A 3 Pin 2P+E Socket With Locked Cover A One No. 32A 3 Pin 2P+E Plug Conforming To Iec 309/1&2 And 200A. Alum Inium Bus-Bar For Two Positive & One Negative Should Be Fixed On Fiber Sheet With Pvc Sleeve Colour Code D. B Mccb & Mcb Should Be Operated Without Opening The Front Cover Inter- Connection With Suitable Siz E Pvc Insulated Copper Conductor Cable Conforming To Is:694/1990 From Bus Bar To Mccb/Mcb To Socket. 3 Core & 4 Core Pvc Insu- Lated And Pvc Sheathed Copper Conductor Flexible Cable Up To 110 V-Shall Be Co Nfirmed To Is:694 With Plugs. Proper Visible Indication Plate Fluorescent Screen Printed On The Front Of Both C Ompartments Shall Be Provided For 415V. Ac Pre-Cooling Box And 110V Dc Battery Charging Box As Approved By Railway. Cthe Box Shall Be Grouted In Ground With Cement Morter Mixing 1:2:4 With Muffing As Per Rail Way Drawing. Note:- It Should Be Ensured: 1 All Cable Connections To Be Db S J.Box Panel Etc. Should Be M Ade Through Proper Size Of Cable Glands/End Fittings No Space Should Be Left Open To Avoid Entry Of Insect S/Lizards Etc. If Necessary, Blanking Plate Should Be Provided In Dbj. 2 Flexible/Rigid Conduits Wherever Provi Ded Should Be With Suitable End Fittings/Clamps Conduit Should Be Secured On Surface Through Suitable Clamps At Regular Interval As Per Is Spec. 3 Sitc As Per Attached Drawing. Warranty Period: 30 Months After The Date O F Delivery

Location
Uttar Pradesh
Due Date
07 May, 2024
Amount
Refer Document
Ref. No #31624068 Central Government And Public Sector Live

Procurement Of Lt Switchgear Spares -Xfmr, Curr, 200/1A, 15Va, Cl-1/5P20, Xfmr, Curr, 150/1A, 0.415/0.66Kv, 7.5Va, Cl-1, Xfmr, Curr, Metering, Wpl, Resin Cast, 100/1A, Xfmr, Curr, 75/1A, 7.5Va, Cl-1, L&T:Fn315/400/630/800 Hndl Asy-B:Sk91279, Mcc:L&T:Fn-200/250 Handle Assy.-B, Mcc:L&T:Fn-32/63 Handle Assy.- Ce, L&T:Handle Assy-A For Fn125:Sk912580000, Xfmr, Pot, 415/110V, 50Va, Cl-1, Xfmr, Pot, 415Vr3/110Vr3, 50Va, Cl-1, Xfmr, Curr, Ring, Resin Cast, 3000/1A, Cl-Ps, Xfmr, Curr, 3000/1A, 0.415/0.66Kv, 7.5Va, Xfmr, Curr, Resin Cast, 1000/1A, Cl-Ps, Xfmr, Curr, 1000/1A, 0.415/0.66Kv, 7.5Va, Xfmr, Curr, 630/1A, 0.415/0.66Kv, 7.5Va, Power Contctr.: 3P, 110Vac, L&T-Mnx18, Pwr.Contctr.: 3P, 110Vac, 110Vac, L&T-Mnx32, Powr Contr:3P415vac:110Vac:L&T:Mnx70, Power Contctr.: 3P, 110Vac, L&T-Mnx110, Power Contactor Mnx225, 415 Volts, Ac3, , Contactor, Power, 415Vac, 400A, 3P, L&T, Coil, Cs94142, L&T, Contactor, Mnx265, Contact Block 1No+1Nc, 2Nd Left-#Cs94207, Contact Block 1No+1Nc-Second Right-Cs942, Side Add On Lhs, 1No+1Nc For Mnx9-40, Cs94, Side Add On Rhs, 1No+1Nc For Mnx9-40, Cs94, Switch Disconnector Fuse Tpn Fn125 L&T, Switch Disconnector Fuse Tpn, Fn250 L&T, Switch Disconnector Fuse Tpn Fn400 L&T, S/W Rotry Waf:4 Way:440V Ac, 32A:Salzer, Rotry Waf S/W On/Off 240Vac 25A Salzer, O/L Mn12l 66-110A, L&T Make, Selectr.Switch: 4-Posn, 16A, 220Vdc;Salzer, S/W Sel:On / Off:16A 220Vdc:Salzer, S/W Sel:2:Pos:16A, 240Vac:Salzer, S/W Rotry Waf:4 Way:660V Dc, 25A:Salzer, Racking Nut For L&T Module, O/L Relay Type Mn2 L&T 0.9-1.5 A, Relay, Thermal O/L, 0.6-1A, Mn2, L&T, Thermal Bi-Metal O/L Relay:Mn2, 0.3-0.5A, Bimetal O/L Relay Type Mn2 Range4.5-7.5A, Thermal Overload Relay:A1.4-2.8, 6-10Amp Over Load Relay L&T Make, Rely Th O/L:14-25 A:L&T Make Mn2, O/L Relay L&T Mn2; 9-15A Singleeph.Prot., Overload Relay Range : 3-5A, Type:Mn2, Thermalo/Lrlymn12, 135A -225A, Ss94138, L&T, Ct Opr Bim;90-150A;Mn12;L&T-Ss94138oomo, Pulling Handle, Sk 91185, L&T, Right Micro Switch For L&T Make Acb, Left Micro Switch For L&T Acb, Microswitch Test/Isolate Position Right, Microswitch Test/Isolate Position Left, Charging Motor, Sl00347oooo, L&T, Closing Coil 220V Dc For L&T Make Bkr., Shunt Release Ea 220V Dc 501-30-98266, Frcd For L&T Make Cn-Cs 4000A Edo, Resistor Kit 220 V D.C.For L&T Acb, Racking Interlock For L&T Breaker, Bezel For C-Pwr.Brkr-1250A, #Sl916020000, Elect Position Indication For L&T Acb, Panel Ingress Seal, D/Out Acb, Stablsng Resstr Varabl 0-2000Ohm200w 1A, Lock A Type For L&T Acb Rackout Locking, Cam Lock For s Of L&T Switch Gear, Interlock For L&T Make Acb, Lt Air Circut Breaker Key Lock T-Aklaf12, Reset Cord For Over Load Relay, Lt Swtch Gr:Reset Cord 1Metre Long, Kit Mount Mn2 Relay Onn Ml0/1/1.5 , 6 Way Sic Block Cat No. Sl92701; L&T, Sec Isoltng Conts+Tbrak-F/M L&T Make, Sec Isoltng Conts+Tserv-F/M L&T Make, Sec Iso Cont Serv Sa92567 For Lt S/G, L&T-Sec Iso Contact Male - Sa92565, Racking Handle Of L&T Modules, Racking Handle For L&T Acb, Aux Cont Kit Typ Fn315 C No.Sk91330 L&T, Aux Cont Kit Typ Fn200/250 C No.Sk91329, Aux Cont Kit Fn100/125/160C No.Sk91328, Auxiliary Contact Kit For Fn63, Aux Contr:L&T:Add On Block-Cs94112, Aux Contr: L&T-Add On Block, Cat-Cs94113, Aux Contr: L&T-Add On Block-Cs94114, Aux Contr: L&T-Add On Block-Cs94120, F, Aux Contactor: L&T-Add On Block-Cs94121, Contactor, Auxiliary, 110Vdc, 6A, 2No+2Nc, Frcd, For, 1250 /2500/4000A, Acb, Spare Kit L&T Make For Mnx110 Contactor, Spare Kit Without Coil Mnx225 Cat-94157, Spare Kit Without Coil Mnx400 Cat-94161, Powr Contr:2P 22Vdc:Cv 220Vdc:200A, Charging Assy, Sl90686oooo, L&T, Front Facia- For Electrical Acb, Sl93202, 220 V Dc Charge L/Switch Assy, L&T

Location
Bihar
Due Date
26 Apr, 2024
Amount
Refer Document