Procurement Of 3 Over Current 1 Earth Fault Numerical Relay Against Ts-1023
Supply Of Spares - Reset Push Button Contact Element, Limit Switch No Nc For Breaker, Micro Switch, Ct Operated Overload, Shunt Trip Coils, No Volt Coilunder Voltage Coil, Catcher Assy 11 05 31, Ammeter, Auxiliary Contactor 2No 2Nc Coil Volt, 24Pin Jones Plug M And F, Fault Imposing Relay Without Base, Potential Transformer, Core Balance Transformer, Earth Leakage Relay 50 750 Ma 750Ma With, Cover Bolts, Isolator Assly K3 On Offf, Overload Assembly Breaker 210A 300 A, Shunt Trip Coil, Arc Chutes, Push Button Actuator For El Test, Incoming Gland, Outgoing Gland, Glass Fuse With Holder, Indicating Lamp With Pcb Mounting, Current Transformer, Ct For Ol, Current Transformer For Ol, Brass Terminals, Push Button With Spindle, Sealing Box Complete, Brass Terminal For Cp, Brass Terminal For Og, Terminal Bushing With Insulator Dmc Inco, Terminal Box Complete, Circuit Breaker For 100A With Complete A, Circuit Breaker For 200A With Complete A, Complete Control Wiring Including Pla R, For Mine Line Make Acbs
Supply Of Ge Alstom Make Battery Earth Fault Relay
Supply of Earth Fault Relay For Sb, Hb, Fb Panel Specification:- Clw Spec. No. Clw/Es/3/0090B Warran Ty Period: 30 Months After The Date Of Delivery
Supply Of Spares Of Keltron Make Battery Charger Systems -Thyr Mdl Dual Pck 95A Slash 1200V F Slash Btry Chrgr, Diode 1N 5408 For Keltron Chargers, Fltr Capctr Elctrlytc 3300 Mfd 350V, Pcb Alarm Anunctr Fr Keltron Btry Chrgr, Alarm Annunciator Pcb B Keltroncharger, Pcb Earth Fault Fr Keltron Btry Chrgr, Card Ctrl F Slash Btry Chrg Keltron, Relay 4R3 220 Vdc With Base And Ret Clips, Shunt 50 Slash 75Mv, Ac Voltmeter 0 500Vac 72Sq Mm Acc, Ac Ammeter 0 75A 72Sq Mm Acc Class, Measurement Ct 75 Slash 5A 5Va, Measurement Ct 50 Slash 5A 5Va, Measurement Ct 25 Slash 5A 5Va, Transistor 2N 3055 With Heat Sink, Zener Diode 24V 1W, Fuse Semicon Gs1000 Slash 500 500A 660V, Capctr 470 Mfd 63V F Slash Btry Chrgr, Resisitor 5K6 Slash 50W Keltron Chargers, 35 Point 6 Kva Transformer For Keltron Charger, 24 Point 93Kva Transformer For Keltron Charger, 17 Point 8Kva Transformer For Keltron Chargers, 9 Point 97Kva Transformer For Keltron Chargers, Diode Tap 100A Slash 1200V F Slash Btry Chrgr, Diode Tap 70A Slash 1200V F Slash Btry Chrgr, Diode Tap 50A Slash 1200V F Slash Btry Chrgr, Diode Tap 25A Slash 1200V F Slash Btry Chrgr, Blocking Diode 200A Slash 1200V F Slash Btry Chrgr, Resistor Bleeder 500E 250W Fr Btry Chrgr, Blocking Diode 150A Slash 1200V F Slash Btry Chrgr, Pcb Snubber Fr Keltron Btry Chrgr, Pcb Sync Signal Fr Keltron Btry Chrgr
Supply of Multi-Function Numerical Relay As Per Bhel Spec No. Cee23017 Rev-00 Item-1 Q3 Numerical Over Current & Ef Relay As Per Bhel Spec No. Cee23017 Rev-00 Item-2. Q3 Battery Earth Fault Protection Relay As Per Bhel Spec. No. Cee22021 Rev-00 Item-2 Q3
Supply of Earth Fault Relay Type Du Qoa/Qop Clw Spec. No. Clw/Es/R-27, Alt.-Z, I Complete Relay A Ssly. Qop-Aal Part No. Ka210013r0064a Or Repl Drg.No.Re-1930100/01. Ii Complete Relay Assly. Qoa-A Al Part No. Ka210013r0064a Or Repl Drg.No.Re-1930100/02. Quantity: Qop 80% & Qoa 20% Warranty Period: 30 Months After The Date Of Delivery