Comprehensive maintenance Of Smoke Detectorfire Alarm, Fire Hydrant Sys And All Misc And Comprehensive Maint Of 13 Nos 10/30 Kva Ups System At Various Wards In New Opd Complex At Base Hospital
Supply of 47 Rs485 To Ethrnt Cnvrtr Icpdas Tds 718 Liu Box Ul Flame Proof Indicating Lamp 24Vac Flameproof Indicating Lamp 110Vac Foam Module Valve 110Vac F Rim Sl Direct On Board As603 Ca1a F Rim Sl Relay Board 1Co 8Ch 24Vdc Imre1ss8 24 Om Relay Board 1Co2ch24vdc Shavison A S36224 Control Command Unit Lvt F Rim Sl Bit Unit Lvt F Rim Sl Fire Detector Lvt Delta 6.1 F Rim Sl Sensor Tube 90M Lvt F Rim Sl Safety Relief Valve F Rim Sl
Provision Of Acs For Lca Provn Of Chemical Earthing Pits At Various Locations ,Provision Of Smoke Detector And Fire Alarm System At Rt Cabin And Exten And Provision Of 3 Phase Power Supply For Operation Of Arrester Barrier At Air Force Station
Supply of Provision Of Linear Heat Detection Lhd Cable In Luggage Portion As Per Rdso Spec No Rdso/2013/Cg-06 Or Latest. The Scope Of Work For Coach Alteration Lug Gage Compartment Area:- A Provision Of 20 Meter. Linear Heat Detector Lhd Cable U L Or En Approved, 105-110 C, Junction Box And Connecting Cable Including Required A Ccessories. B Installation Of Latest Software. C Configuration Of The System To Be Made So That On Receiving A Fire Signal From Luggage Compartment The Buzzer Sho Uld Sound And Dg Set Should Shutdown. D Configuration Of The System To Be Made S O Suppression System Should Not Take Place Automatically. Warranty Period: 30 Months After The Date Of Delivery
Supply of 13 Fire Extinguisher A Fire Extinguisher B Fire Extinguisher C Smoke Detector Fire Extinguisher D
Supply of Fire Fighting Equipments, 90 Supply Installation Testing And Commissioning Of Microprocessor Based 18 Zone Conventional Fire Alarm Panel Compatible Supply Installation Testing And Commissioning Of 04 Zone Conventional Gas Suppression Panel Supply Of Conventional Smoke Detector With Base Supply Of Conventional Heat Detector With Base Supply Of Conventional Hooters Supply Of Heavy Duty Stainless Steel Supply Of Heavy Duty Stainless Steel 304 Grade Fire Hose Cabinet Supply Laying Fixing Connecting Testing And Comissioning Of Pvc Insulated Pvc Sheathed Frls Copper Armoured Cable Refilling Of Co2 Cylinders 45 Kg Waranty 5 Years
Superstructure Of Large Living Shelter Under Job No 2454 As Per Stores List Technical Specification And Drawing Attached For Tenga Circle B And R Items As Per Stores List Attached E And M Items As Per Stores List Attached Earthing Items As Per Stores List Attached Lightening Conductor Items As Per Stores List Attached Fire And Smoke Detectors Items As Per Stores List Attached Furniture Items As Per Stores List Attached
Supply Of File Flat Rough Double Cut, File Half Round Fine Double Cut, File Round Fine Double Cut, File Flat Fine Double Cut, File Square Fine Double Cut, File Triangular Fine Double Cut, Scriber, Centre Punch, Try Square, Divider Spring Joint, Caliper Spring Joint In Side, Caliper Odd Leg Spring Joint, Hammer Ball Pane, Cold Chisel Flat And Cross Cut, Engineers Rule, Tape Measuring, Pliers Combination Insulated, Pliers Long Nose, Pliers Flat Nose, Line Tester, Tweezers, Surface Plate, Oil Can, Surface Gauge Universal, Bench Vice, Hack Saw Tubular Metal Frame Adjustable, Snip Sheet Metal Straight Nose, Snip Sheet Metal Curved Nose, Anvil, Stakes Different Types, Tin Smith, Wooden Mallet Or Nylon Mallet, Round Punch, Electrical Drill Portable Drill With Chuck And Key, Screw Driver Plastic Handle, Screw Driver Plastic Handle Flat Tip, Philips Screw Driver, Soldering Iron Exchangeable Copper Tip, Knife Folded Stainless Steel, Tong Tester Clamp On Multi Meter, Tenon Saw, Firmer Chisel, Rawal Plug Tool, Fire Extinguisher, Fire Buckets, D E Spanner, Ring Spanner, Quick Couples Process Tube Adopter, Tong Close Mouth And Pick, Welding Table For Gas Or Arc, Flaring Tool Set Single Type For Tube, Swaging Tool Punch Type Set Of Size For Tube, Bending Spring External Type For Copper Tube, Pipe Cutter Miniature For Copper Tube, Pinch Of Tool For Copper Tube, Ratchet Spanner, Capillary Plug Gauge, Piercing Pliers Reversing Valve With Access Fitting, Spanner Double Ended, Ring Spanner Off Set, Wrench Adjustable, Valve Key Handle Treated As Consumable, Hollo Punch Hole For Cutting Gasket, Scissor Gasket Cutting Stainless Steel, L Allen Key, T Allen Key Set, Pipe Cutter With Built In Reamer And Space Cutter For Copper Tube, Pipe Or Tube Bender Lever Type, Pipe Wrench, Lapping Plate, Hammer Ball Peen, Puller 3 Legged With Flexible Arm, Hand Blower Portable Complete, Spirit Level Precision Metallic, Tap Set With Matching Drills, Refrigerant Cylinder, Heating Kit With Infrared Bulb, Plumbing Hammer Weight, Cylinder 134 A, Torque Wrench, Piercing Valve, Feeler Gauge, Four Way Reversible Valve, Vernier Height Gauge, Tape Measuring Graduation In Mm, Voltmeter Ac Dc Portable Precision Grade Digital Panel Board Type, Ammeter Ac Dc Portable Precision Grade Digital Panel Board Type, Megger, Wattmeter Multi Range Up, Multi Meter Digital Type, K W Meter, Service Oscillator, C R O Single Beam, C R O Dual Trace Or Double Beam, A F O Oscillators, Pressure Gauge Digital Type, Compound Gauge Digital Type, Service Man Metal Case Thermometer, Gas Leak Detector For Halogen Gas, Electronic Leak Detector, Sling Psychrometer Mounted On Aluminum Back, Stop Watch, Vernier Caliper, Micrometer Outside Measurement, Multi Meter Analogue Type, Tachometer Digital Multi Range, Micron Vacuum Gauge, Sensor Thermometer Digital, Fin Straightened Fin Comb, Filler Gauge, Wire Gauge Metric And British, Dial Thermometer Remote Control Armored Capillary Dial, Anemometer, Compressors Testers For Small Hermetic Compressors, Digital Thermometer, Temperature Humidity Recorder, Instrumentation Screw Driver Set, Digital Weighing Machine
Supply of 148 Addressable Optical Type Fire Smoke Detector Addressable Manual Call Point Optical Type Conventional Fire Smoke Detector Heat Type Conventional Fire Detector Flame Uv Conventional Fire Detector Conventional Optical Beam Smoke Detector Smoke Detector Tester Gas Canister
Supply of Steam For Pm Shri, 62 Milk Purity Detector Contactless Thermometer Acid Base Identifier Pendulum Frequency Calculator Agribot Portable Microscope Gas Leak Detector Smart Warehouse System Firefighting Device Smart Air Quality Monitor Sound Pollution Alert System Vehicle Pressure Monitoring System Hydraulic Crane Steam 100 Easy Steam Activities Stem Activity Book Ph Nitrogen Phosphorous Nitroget Organic Carbon Use Manual Test Report - Msds 3D Printer
Supply of Spares For Fire Alarm System And Public Address System, 153 Smoke Detector Heat Detector Manual Call Station Control Module Wall Mount Speaker
Procurement And Installation Of System For Adequate Arrangement In The Conveyor System - Detector, Flame, Uv-Infra Red, Al, Detector, Infra Red, Ember, Al, Cable, 1.1Kv, 4C, Cu, Pvc, 2.5Mm2, Armrd, Cntrl, Siren, Elec, 2Km Range, Alarm Panel, Fire, 4Zn, Wall Mntd, 24Vdc, Lcd, Call Pt, Ce-En, Ip66, 12-26Vdc, 0-60Degc, Red
Supply of Automatic Smoke/Fire Detection System For Stand-Alone In Lhb Ac Sleeper Coaches, Installation & Commissioning Inclusive., As Per Drawing: Rdso/2008/Cg-04 Rev.06 A Nd Follow Design Lno. Md22161 Dated 18.08.21 For Provision Of Aspiration Type Smoke Detector Sampling Ponts In Lavatories In Place Of Hasp., Packing Instruction: As Per Sta Ndard Packing. It Should Be Ensured That Item Should Not Rub During Transportati On. The Item Should Be Packed With Adequate Strength. Transit Damage, If Any, Shal L Be At The Cost Of Supplier. Warranty Period: 48 Months After The Date Of Delivery Automatic Smoke/Fire Detection System For Stand-Alone Lhb Ac Chair Car, Installation & Commissioning Inclusive., As Per Drawing: Rdso/2008/Cg-04 Rev.06, Packing Instr Uction: As Per Standard Packing. It Should Be Ensured That Item Should Not Rub Durin G Transportation. The Item Should Be Packed With Adequate Strength. Transit Dama Ge, If Any, Shall Be At The Cost Of Supplier. Warranty Period: 48 Months After The Date Of Deliver Y
Supply of Smoke Detector And Fire Alarm System Conforming To Rcf Specification No Edts-087 Rev-B. Not E: The Firm Should Submit Authorized Dealership Certificate Or Proof Of Purchase From Oem Or Dealer And Neces Sary Test Certificates Along With Materials For Acceptance. Warranty Period: 30 Months After The Date Of Delive Ry
Supply of Smoke Detector And Fire Alarm System As Per Bhel Spec No. Or12686 Rev01 With Flame Proof Feature Q3
Supply Of Critical Spares -Generator Bearing Shell For Stg, Generator Bearing Labyrinth Rings Stg, Sealing Ring For Bearing Pedestal Stg, Scrapper Fin For Sealing Ring Of Stg, Jacking Oil Hose For Stg, Stg Generator Bearing Insulation, Output Lead Stg Spare Part, Generator Shaft Earthing Brusha Stg, Generator Shaft Earthing Brushb, Brush Holder For Shaft Earthing Stg, Space Heater For Stg, Rtd For Generator Bearing, Rtd For Hot Cold Air Stg Spare, Fire Detector 100Degc Stg Spare Part, Fire Detector 80Degc Stg Spare Part, Felt For Stand Stg Spare Part, Positive Diode Spare List For Exciter, Negative Diode Spare List For Exciter, Permanent Magnet Generator, Varistor Stg Spare Part, Stg Rotor Input Cablepnhy41360331945 For 3 33 Mw Bhel Make Generators
Annual Operation And Maintenance Contract For E And M Installations At Shravasti Airport, Periodical Maintenance And Operation Of Electrical And Mechanical Installations Involving Operation, Repairs And Maintenance, Attending To Complaints/Faults/ Breakdowns And Taking Rectification Action, Ensuring Serviceability/ Satisfactory Working Condition Of The Systems, Carrying-Out Preventive Maintenance, Maintenance Of Records/ Documents Etc Under This Contract For Shift Duty For All 7 Days On All Working Days Including Saturdays, Sundays And Holidays As Per Tender Specifications, Terms & Conditions By Providing/Engaging Of Electrician & Helper. Shift Purpose- Electrician Skilled- 03 No. Per Day For Shift Duty For All 7 Days In A Week. Helper Un-Skilled- 03 No. Per Day For Shift Duty For All 7 Days In A Week., Monthly Visit Of Fire Technician/Engineer Form Oem Of Fda System Or From Oem Authorized Dealer For Carrying Out Healthiness Check Of Fda System, Attending Faults, Carrying Out Preventive Maintenance I/C Cleaning Etc. As Required To Fire Main Panel And Repeater Panels, Detectors, Response Indicators, Mcp Of The Fda System Etc. Making Replacement Of The Spare Parts/Accessories Etc. If Required For Healthiness Of The Fda System And Submission Of Service Report To Eic. Charges Against Labour & Tools Etc. Required For Attending Faults, Preventive Maintenance, Servicing, Replacement/Installations Of Spare Parts And Accessories Are Included In The Item. All Spare Parts/Accessories Required For Healthiness Of Fda System Shall Be Provided By Aai I.E Paid To The Agency Against Supply Of Materials As In Extra Item On Market Rate On Submission Of Original Invoice And Supporting Documents/Price List Of Oem. Inventory Of Fda System- Main Control Panel & Microprocessor Based Analog Addressable - 01 No. Addressable Multi Detector - 60 Nos Addressable Heat Detector - 4 Nos Ri - 39 Nos Mcp - 3 Nos Addressabel Hooter- 4 Nos Fault Isolator- 4 Nos, Maintenance & Up-Keeping Of Fire Extinguishers, Fire Suppression System And Fire Fighting System Installed At Shravasti Airport Inclusive Of Periodical Checking/ Testing, Servicing, Maintaining Records, Attending Break Down Calls Of All Fire Extinguishers, Hydrant Valves, Hoze Boxes, Pipes, Branch Pipes, Hose Reels, Hose Pipes, Sprinklers, Nrvs, Pipe Lines, Pressure Switches, Main Pumps, Jockey Pumps, Booster Pump, Batteries, Starter Panels, Pressure Gauges, Sluice Valves/Gate Valve Etc As Detailed In The Special Conditions Of The Contract, Particular Specification Etc. Complete As Required. Note- This Item Is Only Service And Does Not Cover Material Part. All Spare Parts/Accessories Required For Healthiness Of Fire Fighting System Shall Be Provided By Aai I.E Paid To The Agency Against Supply Of Materials/Repair Of Equipment As In Extra Item On Market Rate On Submission Of Original Invoice And Supporting Documents/Price List Of Oem., Etc
Supply Of Hot Oil Shuttle Valve, Actuator Seal Kit, Seal Kit For 30Mm Sc Fittings, Side Seals , Interpanel Seals, Dc Valve, Dc Valve, Interposing Relay C/O Contracts:2 Supply:24V Dc , 400A Mccb, Circuit Breaker 630A , Hand Held Control Station, Cable Reeling Drum, Electrical Motor, Local Control Panel, Junction Box, Bridge Plate, Remotly Operated Search Light With Control Panel, Modbus Card, Fire Proof Cable, Detector Continuity Base, Flame Detector For Petrol Station & Paint Store, Ring & Link Switch 4 X Gb Ports , Hrc Fuse, Fuse Link, Hf Fuse Link 4A, Voltmeter,
Supply of Installation Of Fire Alarm System 2739 Addressable Fire Alarm Panel Heat Detector Smoke Detector Manual Call Point Hooter Cum Strobe External 2.5 Amp Power Supply Addressable Relay Module Adressable Controll Module Addressable Fault Isolator Frls Cable
Supply Of Refilling Of Gas And Testing - Refilling Of Novec 1230 Gas, Fm200 Gas, Auto Dialler Replacement Of Defective Auto Dialler In The Suppression System., Valve Servicing Charges, Hfc Cylinders Dismantling And Reinstallation Of Hfc Cylinders In The Fire Suppression System., Novec 1230 Cylinders Dismantling And Reinstallation Of Novec 1230 Cylinders In The Fire Suppression System., Conventional Ravel Smoke Detectors. Replacement Of Defective Conventional Ravel Smoke Detectors., Systems Charges. Loading, Unloading And Installation Of Systems Charges., Hydro Testing Charges Hydro Testing Charges