Icu Unit Tenders

(Select any tender from the list to send an email)
Ref. No #31584976 Central Government/Public Sector Live

Supply of Mri Conditional Dual Chamber Implantable Cardioverter Defibrillator System With Df - 4 Connector And Option Of Dual Shocking Coil.. Sr Ph 154066-Mri Conditional Dual Chamber Implantable Cardioverter Defibri Llator System With Appropriate Atrial And Ventrlar Pace / Sense Leads With Df - 4 C Onnector And Option Of Dual Shocking Coil Leads And Accessories. System Should Hav E Advanced Features For The Reliable Detection And Management Of Ventrlar Tach Ycardia And Ventrlar Fibrillation, Including Features To Differentiate Supra-Ventr lar Tachycardia From Ventrlar Tachycardia And Features To Avoid Inappropriat E Shocks, Tiered Therapy Delivery, Choice Of Atp Protocols And Shock Energies, And S Hould Be Capable Of Delivering Maximum Energy Of 35J Or More And Should Have Featu Res For Management Of High Defibrillation Energy Requirement. Charge Times Should Be Within Clinically Acceptable Limits Throughout The Lifetime Of The Device.Leads Sho Uld Be Low Profile And Choice Of Both Active Or Passive Fixation Leads Should Be Avail Able. Should Have Features For Automatically Alerting The Patient In The Event Of A Ba Ttery Or Lead Fault. Data Storage, Retrieval And Display Should Be Efficient And User Friendly. Data Storage Should Include Episode Details, Therapy Delivered And Results And Electrogram Storage And Should Be Comprehensive. Bradycardia Pacing Includi Ng Independently Programmable Parameters For High Output For Post-Shock Pacing Should Be Available. Warranty Terms Should Be Specified Clearly Along With The Quot Ation. Firms Should Submit Detailed Literature Of The Item In A Bulletin/Tutorial Forma T Which Should Contain All The Details About The Product. Compliance Statement Of E Ach Specification To Be Submitted. The Firm Quoting The Tender Should Submit A Letter Of Authorisation From The Principal Firm/Original Equipment Manufacturer. The Manuf Acturer / Supplier Should Submit Proof Of Supply To A Major Government Institute. Th E Safety And Efficacy Of The Icd Device And The Lead In Clinical Use Should Be Documen Ted In Scientific Publications. All The Above Mentioned Specifications Are Essential An D Mandatory And Should Be Submitted At The Time Of Initial Tender Submission. :No

Location
Tamil Nadu
Due Date
02 May, 2024
Amount
Refer Document