Lighting Protection System Tenders

(Select any tender from the list to send an email)
Ref. No #31625569 Central Government/Public Sector Live   GeM Tender

Supply Of Spares -1.5 Sq.Mm Of Single Core Multi Strand Fr-Lsh Pvc Insulated Industrial Grade Copper Conductor Unsheathed Flexible Cables, 1100 Volt Conforming To Is 694., 2.5 Sqmm. Single Core Multi Strand Fr-Lsh Pvc Insulated Industrial Grade Copper Conductor Unsheathed Flexible Cables, 1100 Volt Conforming To Is 694., 4.0 Sqmm. Single Core Multi Strand Fr-Lsh Pvc Insulated Industrial Grade Copper Conductor Unsheathed Flexible Cables, 1100 Volt Conforming To Is 694 ., 3Cx1.5 Sq.Mm Frls Pvc Insulated And Pvc Sheathed, Multicore, Multi Strand Annealed Bare Copper Conductor Flexible Industrial Cable For Voltage Grade 1100 Volt, Conforming To Is 694. , 3Cx2.5 Sq.Mm Frls Pvc Insulated And Pvc Sheathed, Multicore, Multi Strand Annealed Bare Copper Conductor Flexible Industrial Cable For Voltage Grade 1100 Volt, Conforming To Is 694 . , 3Cx4 Sq.Mm Frls Pvc Insulated And Pvc Sheathed, Multicore, Multi Strand Annealed Bare Copper Conductor Flexible Industrial Cable For Voltage Grade 1100 Volt, Conforming To Is 694 . , 6A To 32A Rating, 240/415V, 10Ka, C Curve Miniature Circuit Breaker Suitable For Inductive Load Of Single Pole In The Existing Mcb Db As Required., 6A To 32A Rating, 240/415V, 10Ka, C Curve Miniature Circuit Breaker Suitable For Inductive Load Of Double Pole Suitable For Existing Mcb Db As Required., 6A To 32A Rating, 240/415V, 10Ka, C Curve Miniature Circuit Breaker Suitable For Inductive Load Of Triple Pole Suitable For The Existing Mcb Db As Required., 6A To 32A Rating, 240/415V, 10Ka, C Curve Miniature Circuit Breaker Suitable For Inductive Load Of Triple Pole And Neutral Suitable For The Existing Mcb Db As Required., 40A Rating, Four Pole, 415V, 50Hz Isolator Suitable For The Existing Mcb Db As Required., 63A Rating, Four Pole, 415V, 50Hz Isolator Suitable For The Existing Mcb Db As Required., 25A Rating, Double Pole Single Phase And Neutral, 240V Residual Current Circuit Breaker Rccb Having A Sensitivity Current 30Ma Suitable For The Existing Mcb Db As Required., 40A Rating, Double Pole Single Phase And Neutral, 240V Residual Current Circuit Breaker Rccb Having A Sensitivity Current 30Ma Suitable For The Existing Mcb Db As Required., 63A Rating, Double Pole Single Phase And Neutral, 240V Residual Current Circuit Breaker Rccb Having A Sensitivity Current 30Ma Suitable For The Existing Mcb Db As Required., Suitable Size Gi Box With Modular Plate And Cover Including Providing 1 No.3 Pin 5/6A Modular Socket Outlet And 1 No. 5/6A Modular Switch Etc. Complete As Required., Suitable Size Gi Box With Modular Plate And Cover Including Providing 1 No.6 Pin 5/6A & 15/16A Modular Socket Outlet And 1 No. 15/16A Modular Switch Etc. Complete As Required., Heavy Duty Pvc Casing Capping- Casing Bearing Isi Mark Of Size- 20Mmx12mm, Heavy Duty Pvc Casing Capping- Casing Bearing Isi Mark Of Size- 25Mmx16mm, 5/6 Amp Switch Modular Type Switch/Socket For The Existing Modular Plate & Switch Box Etc. Complete As Required., 15/16 Amp Switch Modular Type Switch/Socket For The Existing Modular Plate & Switch Box Etc. Complete As Required., 3 Pin 5/6 Amp Socket Outlet Modular Type Switch/Socket For The Existing Modular Plate & Switch Box Etc. Complete As Required., 6 Pin 15/16 Amp Socket Outlet Modular Type Switch/Socket For The Existing Modular Plate & Switch Box Etc. Complete As Required., Call Bell Suitable For Single Phase, 230V Complete As Required At Site., 2X2 Feet 36 W Led Light Fixture Recess Type Suitable For Operation On Single Phase 230V, 50Hz Power Supply Complete As Required As Per Enclosed Technical Specification ., 3- Pin, 5/6 Amp Isi Marked Plug Top Suitable For Operation On Single Phase 230V, 50Hz Power Supply., 3- Pin, 15/16 Amp Isi Marked Plug Top Suitable For Operation On Single Phase 230V, 50Hz Power Supply., Red Outer Lens For Rwy End Light Suitable For Existing Airfield Ground Agl Complete As Required . Existing Light Fixture Is Of Vardhman Make, Green Outer Lens For Rwy Threshold Light Suitable For Existing Airfield Ground Agl Complete As Required . Existing Light Fixture Is Of Vardhman Make, Yellow Filter For Runway Edge Light Suitable For Existing Airfield Ground Agl Complete As Required . Existing Light Fixture Is Of Vardhman Make, 5 Kv Grade Plug & Receptacle Type-I Suitable For Single Core 6 Sqmm Airfield Cable Complete As Required ., 150W, 6.6/6.6A Halogen Lamp Pk30d64361 Hlx-Z, Make -Osram Or Equivalent Suitable For Existing Agl/ Cat-I Fittings Complete As Required ., 200W, 6.6/6.6A Halogen Lamp Pk30d64382 Hlx-C Make - Osram Or Equivalent Suitable For Existing Agl/ Cat-I Fittings Complete As Required ., Isolating Transformer Of 15 Watts, 6.6A/6.6A, 5Kv, 50Hz Suitable For Existing Agl/Cat-I Light Fixtures Complete As Required, Isolating Transformer Of 45 Watts, 6.6A/6.6A, 5Kv, 50Hz Suitable For Existing Agl/Cat-I Light Fixtures Complete As Required, Isolating Transformer Of 100 Watts, 6.6A/6.6A, 5Kv, 50 Hz Suitable For Existing Agl/Cat-I Light Fixtures Complete As Required, Isolating Transformer Of 150 Watts, 6.6A/6.6A, 5Kv, 50 Hz, Suitable For Existing Agl/Cat-I Light Fixtures Complete As Required, Isolating Transformer Of 200 Watts, 6.6A/6.6A, 5Kv, 50 Hz Suitable For Existing Agl/Cat-I Light Fixtures Complete As Required, Beacon Lamp Of 1000W Par64 Ffp 120Vac Or Equivalent Suitable For Existing Becon Light Fixture Complete As Required., Cable Jointing Kit For 1X6 Sqmm Afl Cable Complete As Required ., Hrc High Speed Fuse-Semi Conductor Fuse-Bs88 Type, 100Fe, 100A Rating, Voltage 690Vac, Breaking Capacity 200 Ka Suitable For Existing Switch Gear Make-Bussmann Series Eaton Or Equivalent For Electrical And Agl And Cat I

Location
Uttar Pradesh
Due Date
29 Apr, 2024
Amount
Refer Document
Ref. No #31615978 Central Government/Public Sector Live   GeM Tender

Procurement Of Spares - Circuit Breaker Sub. Assy Comp. With Ct And Incoming And Outgoing Lead Cb, Part No. Cb 200Bc, Earth Leakage Relay Part No. Cb 200C 3Ma, Fixed Contact, Part No.Cb 200B 1, Moving Contact, Part No.Cb 200B 2, Moving Contact Carrier, Part No.Cb 200B 3, Fixed Contact Carrier, Part No.Cb 200B 4, Copper Braided Wire For Moving Contact, Part No.Cb 200B 9, Control Panel Assy. With Upto 750Ma Earth Leakage Relay, Part No.Cb 200C Ma, Auxiliary Transformer 100Va, Part No.Cb 200C 1A, Test Microswitch, Part No.Cb 200C 5, Microswitch For Earth Leakage Lamp, Part No.Cb 200C 7, Bridge Rectifier, Part No.B 200C 9, Isolator On Off Heavy Duty, Part No.Cb 200D 1 Hd, Current Transformer For Overload, Part No.Cb 200D 3B, Current Transformer For Ammeter, Part No.Cb 200D 3C, Ammeter, Part No.Cb 200D 4, Earth Leakage Lamp Holder With Lamp, Part No.Cb 200D 5, Brass Gland, Part No.Cb 200D 7A2, Lead Cone, Part No.Cb 200D 7A3, Test Reset Spindle With Flapper, Part No.Cb 200D 10, Test Reset Key, Part No.Cb 200D 10A, Ht Bolt For Front Cover, Part No.Cb 200D 11, Ht Bolt For Top Cover, Part No.Cb 200D 11A, Ht Bolt For Cable Box, Part No.Cb 200D 11B, Incoming Terminal, Part No.Cb 200D 12, Throughgoing Terminal, Part No.Cb 200D 12A, Interconnecting Terminal, Part No.Cb 200D 12B2, Outgoing Terminal, Part No.Cb 200D 12C2, Incoming Terminal Dmc Moulded, Part No.Cb 200D 12Fn, Throughgoing Terminal Dmc Moulded, Part No.Cb 200D 12Gn, Interconnecting Terminal Dmc Moulded, Part No.Cb 200D 12Hn, Outgoing Terminal Dmc Moulded, Part No.Cb 200D 12In, Copper Busbar With Sleeving R, Part No.Cb 200D 13, Copper Busbar With Sleeving Y, Part No.Cb 200D 13, Copper Busbar With Sleeving B, Part No.Cb 200D 13, Incoming Lead Cb, Part No.Cb 200D 16B, Outgoing Lead Cb, Part No.Cb 200D 17B, Isolator Lead Incoming, Part No.Cb 200D, Isolator Lead Outgoing, Part No.Cb 200D 20A, Emergency Trip Relay, Part No.Cb 200D 23, Fixed Contact Part No. Cb 300B 1, Moving Contact Part No. Cb 300B 2, Moving Contact Carrier, Part No.Cb 300B 3, Fixed Contact Carrier, Part No.Cb 300B 4, Copper Braided Wire For Moving Contact, Part No.Cb 300B 9, Shunt Trip Coil, Part No.Cb 300B 15, Control Panel Assy With Upto 750Ma El Relay, Part No.Cb 300C Ma, Test Microswitch, Part No.Cb 300C 5, Resistance, Part No.Cb 300C 6, Bridge Rectifier, Part No.Cb 300C 9, Sensitive Cbt For Earth Leakage Relay 750Ma, Part No. Cb 300D 2 Ma, Earth Leakage Lamp Holder With Lamp, Part No.Cb 300D 5, Isolator Interlocking Microswitch, Part No. Cb 300D 6, Brass Gland, Part No.Cb 300D 7A2, Ht Bolt For Front Cover, Part No.Cb 300D 11, Ht Bolt For Top Cover, Part No. Cb 300D 11A, Ht Bolt For Cable Box, Part No. Cb 300D 11B, Incoming Terminal Dmc Moulded, Part No. Cb 300D 12Fn, Throughgoing Terminal Dmc Moulded, Part No. Cb 300D 12Gn, Interconnecting Terminal Dmc Moulded, Part No. Cb 300D 12Hn, Outgoing Terminal Dmc Moulded, Part No. Cb 300D 12In, Copper Busbar With Sleeving- R, Part No. Cb 300D 13, Copper Busbar With Sleeving- Y, Part No. Cb 300D 13, Copper Busbar With Sleeving- B, Part No. Cb 300D 13, Incoming Lead Cb, Part No. Cb 300D 16C, Outgoing Lead Cb, Part No. Cb 300D 17C, Circuit Breaker Sub. Assy.Comp. With Ct And Incoming And Outgoing Lead Cb, Part No.Cb 400Bc, Fixed Contact, Part No.Cb 400B 1, Moving Contact, Part No.Cb 400B 2, Moving Contact Carrier, Part No.Cb 400B 3, Fixed Contact Carrier, Part No.Cb 400B 4, Copper Braided Wire For Moving Contact, Part No.Cb 400B 9, Control Panel Assy. With Upto 750Ma Earth Leakage Relay, Part No.Cb 400C Ma, Auxiliary Transformer 100Va, Part No.Cb 400C 1A, Test Microswitch, Part No.Cb 400C 5, Microswitch For Earth Leakage Lamp, Part No.Cb 400C 7, Bridge Rectifier, Part No.Cb 400C 9, Isolator On Off Heavy Duty, Part No.Cb 400D 1Hd, Current Transformer For Overload, Part No.Cb 400D 3F, Current Transformer For Ammeter, Part No.Cb 400D 3G, Ammeter, Part No.Cb 400D 4, Earth Leakage Lamp Holder With Lamp, Part No.Cb 400D 5, Brass Gland, Part No.Cb 400D 7A2, Lead Cone, Part No.Cb 400D 7A3, Test Reset Spindle With Flapper, Part No.Cb 400D 10, Test Reset Key, Part No.Cb 400D 10A, Ht Bolt For Front Top Cover, Part No.Cb 400D 11, Ht Bolt For Cable Box, Part No.Cb 400D 11A, Incoming Terminal, Part No.Cb 400D 12, Throughgoing Terminal, Part No.Cb 400D 12A, Interconnecting Terminal, Part No.Cb 400D 12B, Outgoing Terminal, Part No.Cb 400D 12C, Incoming Terminal Dmc Moulded, Part No.Cb 400D 12Fn, Throughgoing Terminal Dmc Moulded, Part No.Cb 400D 12Gn, Interconnecting Terminal Dmc Moulded, Part No.Cb 400D 12Hn, Outgoing Terminal Dmc Moulded, Part No.Cb 400D 12In, Copper Busbar With Sleeving-R, Part No.Cb 400D 13, Copper Busbar With Sleeving-Y, Part No.Cb 400D 13, Copper Busbar With Sleeving-B, Part No.Cb 400D 13, Incoming Lead Cb, Part No.Cb 400D 16, Outgoing Lead Cb, Part No.Cb 400D 17, Isolator Lead Incoming, Part No.Cb 400D 19, Isolator Lead Outgoing, Part No.Cb 400D 20, Emergency Trip Relay, Part No.Cb 400D 23, Transformer Panel With All Components But With Transformer, Part No.Sdp A-0001A, Electromagnetic Earth Leakage , Part No.Sdp A-0001 2, Bridge Rectifier Unit, Part No.Sdp A0001 2D, Diode, Part No.Sdp A-0001 2D1, Condenser, Part No.Sdp A-0001 2D2, Relay Base With Wiring, Part No.Sdp A0001 2E, Thermal Overload Relay, Part No.Sdp A-0001 5, Hrc Fuse, Part No.Sdp A-0001 6, Test Reset Microswitch, Part No.Sdp A-0001 8, Leakage Indication Lamp, Leakage Indication Lamp Holder, Part No.Sdp A-0001 10, Glass Cartidge Fuse, Part No.Sdp A0001 11, Glass Cartidge Fuse Holder, Part No.Sdp A-0001 12, Dmc Pin Insulator, Part No.Sdp A-0002 1A, Pin Contacts Pilot, Part No.Sdp A-0002 1B, Pin Contacts Main, Part No.Sdp A-0002 1B1, Brass Gland, Part No.Sdp A-0009 A1, 30A Restrained Plug And Socket Complete, Part No.Sdp A-0002, G.I. Stud With Nut, Part No.Sdp A-0009 A4n, Test Reset Key, Part No. Sdp A-0012, Ht Bolt For Terminal Box, Part No.Sdp A-0014, Ht Bolt For Elbow, Part No.Sdp A-0015, Ht Bolt For Plug And Socket, Part No.Sdp A-0016, Sensitive Earth Leakage Relay Upto 750Ma, Part No.Sdp A-0019Ma, Machanical Latch Type Earth Leakage Relay With Contact Block, Part No.Sdp A-0020, Isolator Reversing 200A, Part No.Fg 101, Terminal With Insulator Incoming, Part No.Fg 104, Terminal With Insulator Throughgoing, Part No.Fg 104A, Terminal With Insulator Inconnecting, Part No.Fg 104B, Dmc Terminal Bushing, Part No.Fg 104C, Copper Busbar With Sleeving- R, Part No.Fg 105, Copper Busbar With Sleeving- Y, Part No.Fg 105, Copper Busbar With Sleeving- B, Part No.Fg 105, Brass Gland, Part No.Fg 107A1, Auxiliary Contactor, Part No.Fg 110 C, Main Contactor 200Amps, Part No. Fg 110 1, Leakage Indication Lamp, Part No.Fg 114, Sensitive Earth Leakage Relay Upto 750Ma, Part No.Fg 115Ma, Sensitive Cbt For Earth Leakage Relay 750Ma, Part No.Fg 116Ma, Selenium Bridge Rectifier, Part No.Fg 117, Resistance, Part No.Fg 118, Auxiliary Transformer 150Va, Part No.Fg 119A, Pilot Relay, Part No.Fg 120, Test Reset Key, Part No.Fg 129, Ht Bolt For Front Cover, Part No.Fg 132, Ht Bolt For Top Cover, Part No.Fg 133, Ht Bolt For Terminal Box, Part No.Fg 134, Toggle Switch, Part No.Fg 139, Fuse Base For Short Fuse Link, Part No.Fg 140, Fuse Base Forcontrol Link, Part No.Fg 140An, Fuse Link For Short Circuit , Part No.Fg 141, Fuse Link For Control Circuit, Part No.Fg 141An, Diode, Part No.Fg 142, Condenser, Part No.Fg 143, Plug And Socket Assly.Comp. 200Amp, Sdl Side, Part No. Fg 146, Plug And Socket Assly.Comp. 200Amp, Geb Side, Part No. Fg 147, Pt For Transformer 400Va, 550V, 12V, 24V Sdl Side, For Abc Make Electrical Equipments

Location
Chhattisgarh
Due Date
20 Apr, 2024
Amount
Refer Document