Supply of Helmet: The Helmet Should Confirm To Is: 2925 With Latest Amendments With The Following Additional Features: 1. Comfortable To Wear. 2. A Strong Chinstrap, With Limits Of Risk Of Losing The Helmet During A Fall. 3. Venti Lation Holes Allow Airflow Through The Helmet Ventilation Holes To Allow The Ventilation To Be Adjusted As Needed. 4. I T Should Have Designed For Optimal Attachment Of A Headlamp, A Protective Shield, And Hearing Protection. 5. It Sho Uld Absorb Impacts By Deformation Of The Expanded Polystyrene Liner. 6. Center Fit Adjustment System Adjusts The Headband And Keeps The Helmet Centered On The Head. Head Lamp: The Head Lamp Should Confirm To En 60079- 15- 2005 & En 60079-0-2006 With Latest Amendments With The Following Features: 1. Constant Lighting Technology Ensures Brightness That Does Not Gradually Decrease As The Battery Drains. 2. 3 Lighting Levels And Boost Mode As Per E81 With Head Lamp Brightness: 35 Lumens, Flood Beam: Ledx4. 3. The Headlamp Must Be Provided With T Wo Operating Mode Charger And Aaa/Lr 06 Rechargeable Battery. 4. Lighting For Professionals That Is Reliable, Pra Ctical And Durable. 5. Two Lighting Modes Low And High. 6. Mode For Close-Range Work: Comfortable Flood Beam F Or Proximity Vision. 7. Automatically Switches To Reserve Mode When Batteries Are Almost Drained Signaled By Bli Nking Light. 8. Rotating Knob That Is Ergonomic, Even With Gloves. 9. May Be Used In Explosive Environments. 10. Excellent Resistance To Falls 2M, Impacts, And Crushing 80Kg. 11. Comfortable And Washable Elastic Headband . 12. Resistant To Chemicals. 13. Weight: 160Gmaximum. 14. Beam Pattern: Flood. 15.The Headlamp With Water Tightness If Immersed In Water For 30 Minutes. Warranty Period: 30 Months After The Date Of Delivery
Applications In The Prescribed Forms Are Hereby Invited From Eligible Interested Experienced Individuals/Agency/Firms/Company/Dealership For Allotment Of Block-A 1.464 Acre Of Central Garage, Sector-06 With Rcc Roofing Of Plinth Area 14148 Sq.Ft. 0.324 Acre And Appurtenant Land Measuring 49644.5 Sq. Ft. 1.139 Acre, On As Is Where Is Basis And “No Complaints Basis” For The Purpose Of Operating “Manufacturer’S Authorized Auto Sale & Service Centre For Light Motor Vehicles
Supply Of Epoxy Resin Cast Ct, Highest System Voltage 7.2Kv, Ctr 1000/5/5/1A, Burden 20Va, Accuracy Class 5P20, Supply Voltage-6.6Kv, Rated Frequency 50 Hz, As Per Is 2705, Indication Lamp With Holder Dia 30.5Mm Led Type 110V Dc Red, Transformer Oil Acidity Testing Kit, Set Of 50, Insulating Mat, Confirming To Is - 15652-2006, A-C Proof Of Voltage Upto 33Kv, As Per Specs Mentioned In Atc, Digital Time Switch 240V Ac, Contactor Current Rating 16A, 30Kv Grade Metal Oxide Type Lightning Arrester, Suitable For 33Kv System Voltage, Outdoor Use, Creep Age Distance Minimum 900Mm, Confirming To Is 3070-3 1993, Coil, Dc 110V, Operating, Etc
Supply of Black Light Set For Magnaflux Testing With Separate Control Transformer, Hand Held Light Weight. Mini Mum Intensity 4000Micro Watt, Visible Emission At 325Mm Height, 10 Lux Bulb. Multiple Led Filter For Ultraviolet Li Ght Filtering. Operating Voltage220-240V, 50 Hz And 1 Ph Input To Be Supplied With Carrying Case. Make: Super Mag/Ndt Or Labino Or Karl Deutsch Only Warranty Period: 30 Months After The Date Of Delivery
Procurement Of Cap Lamp With Strap With Charger Having Smf Li-Ion Battery3.7V Havaing L Ed Light Weighing Approx 220 Grams.Operating Temperature -10 Degree C To 50 Degree C W Ith Ingress Protectionip And As Per Annexture Attached. Warranty Period: 30 Months Aft Er The Date Of Delivery
Supply of Led-Based Loco Signal Exchange Light One Set Consists Of Four Sets Of Le D Lights Red And Green And Four Nos. Of Operating Panel Having Operating Voltage 110V Dc +/-22.5% As Per Rdso Modification No.Rdso/2018/El/Ms/0470, Dated: 18.06.2018 And D Rg No. Alt-Ses-L-78, Rev No- 00 As Well As Drg No. Alt-Ses-C-77, Rev No. 00. Warranty Period: 30 Months After The Date Of Delivery
Procurement Of Adjustable Spot Light For Driver And Assistant Driver Desk Illumination L Amp Should Be Led Based And Operating Voltage 110 Volt Dc For Locos.Entire Assem Bly Should Confirm To Spcn No. Clw Spcn.No. Clw/Es/3/0042/D Except Lamp, Which Shou Ld Be Led Based With Operating Voltage 11O Volt Dc, Quality Of Led Should Be Tested As Per Clw Spcn No Clw/Es/3/0654, Para 2 Technical Data, Where Voltage To Be Conside Red As 110 V Instead Of Indicated 24V. Warranty Period: 30 Months After The Date Of Delivery
Supply of Lightening Arrestor Supply Of Metal Oxide Lightning Arresterla Heavy Duty Station Class Metal Oxide Gapless Lightning Arrester Morester Type Stn-D Type Heavy Duty Station Class Metal Oxide Gaples S Lightning Arrester Morester Type Stn-D Reference Standard Iec 99-4 Of 2006/Is 3070 Part3 1993 No Of Unit One Rated Voltage 30Kv Nominal Discharge Current With Class 10Ka Class 1 Reference Current 2 Ma Pea K Reference Voltage Greater Than Rated Arrester Voltage At Reference Leakage Current At Cov Less Than 0.8 Ma M Ax Continuos Operating Voltage 24Kv Rms Maximum Residual Voltage For Discharge Current Of 8/20 Micro Sec Wav E 5000 Amps 85Kvpeak 10000 Amps 90Kvpeak 20000 Amps 100Kvpeak Max Steep Front Residual Voltage At 10 Ka With One Micro Sec Rise Time 100Kvpeak Max Switching Impulse Residual Voltage With 40/80 Us Wave At 1000 A Mps 80Kvpeak Energy Dissipation Capability Form 3 Seqential Shots 6 Kj /Kv High Current 4/10 Us Test Value 100Ka Peak Long Duration Current Tests Current Peak Virtual Duration As Per Discharge Class 2 Of Iec -99-4 Table -4 200 0 Micro Sec Pressure Relief Class Class A Short Circuit Current Capability 40Ka Rms Partial Discharge At 1.05 Time S Mcov Less Than 10Pc 0.1 Second 34.5Ka Rms 0.1 Second 33.5Ka Rms 10.0 Second 31.5Ka Rmsinsulation Withst And Tests On Arrester Housing One Minute 50 Hz Dry & Wet 95Ka Rms Lightning Impulse Voltage Withstand 175Ka R Ms Creepage Distance Mm 900 Nominal Weight Of Complete Unit 11?10% Kgs Height Of Complete Unit From Bas E To The Line Side Refer Drg No 2500300 Minimum Recommended Contre To Centre Spacing Between Arresters500 Mm Clearance Required Form Ground Equipment At Various Heights Of Arrester 400 Mm Earthing Arrangement Pro Vided For Earthing Side Of Arrester Ground Terminal Bracket Provided For Connecting Earth Strip Drg No 6220151 M Ounting Flange Dimensional Details End Casting 3 Holes 11Mm 120 Deg Apart At 165Mm Pcd Rated Frequency 50 Hz ? 5% Insulation Material Porcelani Specific Creepage Distance 25Mm/Kv Altitude Above Sea Level 1000/ Mtrs. From Msl Minimum Humidity 85% Markings 99-4 Of 2006/Is 3070 Part3 1993 Earthing Switch Operating M Echanism Independent Manual Drive, Mechanically Interlocked With Main Blades Attached As Per Annexure-A Warranty Period: 12 Months After The Date Of Delivery
Supply of Adjustable Spot Light For Driver And Assistant Driver Desk Illumination Lamp Should Be Led Based And Operating V Oltage 110 Volt Dc For Locos. Entire Assembly Should Confirm To Clw Spec. No. Clw/Es/3/0042/D Except Lamp, Which Shoul D Be Led Based With Operating Voltage 110 Volt Dc, Quality Of Led Should Be Tested As Per Clw Spec. No. Clw/Es/3/0654, P Ara 2 Technical Data, Where Voltage To Be Considered As 110 V Instead Of Indicated 24V. Warranty Period: 30 Months After T He Date Of Delivery