Pacemaker Tenders

(Select any tender from the list to send an email)
Ref. No #31651638 Central Government/Public Sector Live   GeM Tender

Supply Of Cath Lab Consumables Coronary Stents Usfda Approved, Balloons 1Point0 X 10Mm, Balloons 1Point5 X 10Mm, Balloons 2Point0 X 10Mm, Balloons 2Point5 X 10Mm, Balloons 3Point0 X 10Mm, Balloons 3Point5 X 10Mm, Balloons 4Point0 X 10Mm, Balloons 3 X 10Mm, Balloons 4 X 8Mm 4Point X 8Mm, Cutting Balloon All Size, Permenent Single Chamber, Permenent Dual Chamber, Temporary With Extra Leads Single, Temporary With Extra Leads Dual, Pda Devices, Asd Device, Pfo Device, Sheath Dilator And Loader Accessory Set, Delevery Cable Accessory Set, Ptmc Balloon, La Wire, Dilator, Ms Tube, Syringe 150Ml For Power Injector, Syringe 200Ml For Power Injector, Syringe 50 Ml For Power Injector, Ptmc Kit, Ptmc Balloon La Wire Dilator Ms Tube Stylet And Syringe, Tavi Device, Aortic Valve Delivery Catheter, Aortic Valve Loading Systems, 5F Pigtailx8, 4F Pigtailx8, 5F Multipurpose Catheter End Hole X8, Amplzter Or Other Extra Stiff J Tip Wire 0Point035, Amplzter Or Other Extra Stiff Strieght Tip Wire 0Point035, Exchange Length Strieght Tip 200Cm 0Point02x10, Exchange Length J Tip 200Cm 0Point02x10, Strieght Tip Exchange Length 0Point032x10, J Tip Terumo Exchange Length 150 Cm, Sv5 Wire, V18 Wire, Tyshak Balloons, Disposible Perforator Size 8No, Disposible Perforator Size 10 No, Disposible Perforator Size 14 No, Disposible Perforator Size 12 No, Diagnostic Cathethers, Guiding Cathethers, Coronary Wires, Ptca Wire, Guidewires, Radial Sheath 5Fr, Radial Sheath 6Fr, Radial Sheath 8Fr, Radial Sheath 9Fr, Radial Sheath 10Fr, Radial Sheath 12Fr, Femoral Sheath 6Fr, Femoral Sheath 7Fr, Femoral Sheath 9Fr, Femoral Sheath 10Fr, Femoral Sheath 12Fr, Inflation Device, Y Connector, Radio-Opaque Dye, Manifold 3 Way, Pressure Line, Pressure Bag, Introducer Needle 18 G, Jelco Pink, Thrombustor, Microcatheter, Snare 15 Mm, Graftmaster, Guide Linar Catheter, Puncture Needle Radial, Ambulation Coil, Electric Warming Blanket Pead Dispo, Electric Warming Blanket Neonate Dispo, Electric Warming Blanket Adult Dispo, Eto Cartridge 150 Gms, Printing Paper Roll For Eto

Location
Maharashtra
Due Date
11 May, 2024
Amount
Refer Document
Ref. No #31609549 Central Government/Public Sector Live

Supply of Srph154036-Mri Conditional Dual Chamber Rate Responsive Ddd R With Appropriate Atrial And Ventricular Bipolar Steroid Eluting Lead Mri Conditi Onal With Life Warranty Provision Of Pacing Therapy For The Use Of The Patients Lif E-Time Including Any No. Of Pulse Generator Replacements As Clinically Required. S Hould Have The Latest Technological Features To Provide Proportionate, Smooth A Nd Appropriate Response Of Pacing Rate To Increased Metabolic Demand, Should Pr Ovide For Atrial And Ventricular Pacing And Sensing With Choice Of At Least 16 Mode S Of Operation, Appropriate Safety Features To Avoid Cross Talk, Optimum Flexibilit Y Of Programming Including Minimal Av Delay Of 30Msec Or Less And Atrial Sensitivit Y Of 0.2Mv Or Less, Detailed Data Storage With Easy Retrieval And Display Of Advanc Ed Diagnostics For Ease Of Clinical Follow Up & Maximal Longevity. Should Be Capabl E Of Programming For Prolonging Longevity And Maximal Cost Effectiveness. Shoul D Be Capable Of Providing Reliable Ventricular Capture With Lowest Battery Drain S O As To Provide Maximum Longevity Of The Pacing System. Preferably As An Automati C Feature Where The Pulse Generator Can Perform A Periodic Threshold Test And R Eliably Verify Ventricular Capture And Adjust Ventricular Pulse Output Parameter S To Minimize Battery Drain Without Compromising Patient Safety. Should Have Feat Ures For Automatic Management Of Arrhythmias Including Mediated Arr Hythmias As Well As Automatic Mode Switching Mode Switch Should Be To And From Ddd To Ddi/Vvir, Provision Of Rate Responsive Pacing After Mode Switch And Automat Ic Reversion To Ddd After Termination Of Mode Switch Triggering Arrhythmias. Sho Uld Have Algorithms To Promote Intrinsic Conduction. Both Atrial And Ventricular Channels Should Have Provision For High Energy Output I.E. Up To At Least 6.0 Volts Pulse Amplitude And Pulse Width Up To Atleast 1.0 Ms, Follow Up Diagnosis And Repro Gramming Should Be Rendered As Effective As Possible Through Provision Of Adequ Ate Information Management Systems On The Programmer. Mri Compatible Leads Sho Uld Be Bipolar, Steroid Eluting And Low Profile Either Tined Or Active Fixation Type 7F Or Smaller Introducer Individually. Leads Should Be From The Same Manufacture R I.E. Manufactured By The Same Company As The Pulse Generator, Not Outsourced A Nd Marketed By Another Company. Pulse Generator And Leads Should Be Suitable Fo R Adult And Paediatric Patients. The Manufacturer / Supplier Should Submit Proof O F Supply To A Major Government Institute. Publications Supporting The Safety And E Fficacy Of The Device And The Leads In Clinical Use Should Be Available In Peer Reviewed Journals. The Latest Programmer With Up Dated Software Should Be Available At All Times Permanently In The Hospital. The Programmer Should Have Fac Ilities For Simultaneous Display Of Multiple Surface Ecg Leads, Intracardiac Electr Ograms, Event Markers, Electronic Calipers And For Recording The Same Both On P Aper And In Electronic Storage Media E.G. Compact Disc Etc., Unit:No

Location
Tamil Nadu
Due Date
03 May, 2024
Amount
Refer Document
Ref. No #31609564 Central Government/Public Sector Live

Supply of Srph154052-Single Chamber Rate Responsive System Should Be Mri Conditional With Appropriate Bipolar Mri Conditional Lead. Should Have The Lat Est Technological Features To Provide Proportionate, Smooth And Appropriate Re Sponse Of Pacing Rate To Increased Metabolic Demand. Should Be Suitable For Use In Adult And Children. Should Have Sufficient Programming Flexibility For Using In Atri Um Where Sensitivity Should Be Adjustable To 0.25Mv Or Lower And / Or Ventricle An D Should Be Supplied With Low Profile Atrial / Ventricular Mri Compatible Lead. To B E Specified When Taking Delivery. The Lead Should Be Low Profile 7F Or Smaller Intr Oducer And Should Be Steroid Eluting. Should Be Capable Of High Energy Output Pa Cing With Pulse Amplitude Of Up To At Least 6.0V And Pulse Width Up To Atleast 1.0Ms. T He Pacing System Should Have Maximum Flexibility Of Programming, Data Storage An D Display For Ease Of Clinical Follow Up And Diagnosis Of Malfunction. Should Be Co Vered By Life Warranty. Providing Pacing Therapy For The Duration Of Patients Life Time. Should Provide Free Of Charge The Latest Programmer With Appropriate Soft Ware Which Should Have Facilities For Simultaneous Display Of Multiple Surface Ec G Leads, Intracardiac Electrograms, Event Markers, Electronic Calipers And For R Ecording The Same Both On Paper And In Electronic Storage Media E.G. Compact Disc S Etc., The Safety And Efficacy Of The Pacing System Should Be Documented In Scient Ific Publications. Unit:No

Location
Tamil Nadu
Due Date
17 May, 2024
Amount
Refer Document
Ref. No #31550954 Corporations/Associations/Others Live

Supply of Temporary Dual Chamber

Location
Kerala
Due Date
27 Apr, 2024
Amount
2.56 Lacs
Ref. No #31550976 Corporations/Associations/Others Live

Supply of Temporary Single Chamber

Location
Kerala
Due Date
27 Apr, 2024
Amount
1.05 Lacs