Pole Fittings Tenders

(Select any tender from the list to send an email)
Ref. No #31629118 Central Government/Public Sector Live

Supply of 415 Volts Ac Pre-Cooling Cum 110V. Dc Battery Charging Box Shall Be Fabricated With Ms Sheet 3Mm Thick And Ms Angle Of Size 40X40x5 Mm. The Box Shall Be Out Door Type, Floor Mounted Weather, Dus T & Vermin Proof With Degree Of Protection Ip54. It Shall Be Divided Into Two Compartments Of Equal Size Whi Ch Shall Have Independently Hinged Doors For Both The Compartments Lockable And Double Earthing Terminal Proper Canopy Shall Be Provided On The Top To Prevent Rain Water Entering Inside The Box. Separate Detach Able Plate 3Mm Thick Ms Sheet For Both Compartment Shall Be Provided 100 Mm Dia. Hole With Groomet For Incoming And Outgoing Cable. Incoming & Out Going Cable Shall Be Connected With The Bus-Bar From Bottom Side. The Box Shall Be Finished With Powder Coating Of Approved Colour Thickness Not Less Than 40 Microns. A1st Compartment Shall Be Suitable For Accommodating 1 No. 100 A. 4 Mccb Fixed Type Thermal Mag Netic Release 35 Ka Breaking Capacity And Conforming To Is:13947/Part-2 & Iec: 60947/2, One 63A 5Pin 3P+ N+E415 V. Panel Mounted Socket With Spring Locked Cover & One 63A. 5 Pin 3P+N+E 415 V. Plug Conformi Ng To Iec 309/1&2, One No.16A.3Pin2p+E 250 V. Panel Mounted Socket With Spring Locked Cover & 1No. 16A 3 Pin2p+E 250 V. Plug Conforming To Iec 309/1&2 And 200A. Aluminium Bus-Bar For Phases & Neutral Shoul D Be Fixed On Fiber Sheet With Pvc Sleeve Colour Coded. 2Nd - Compartment Shall Be Suitable For Accommo Dating 1 No. 32 A. Dc Series Mcb Dp Suitable For 130 V Dc Supply, One No. Panel Mounted 32A 3 Pin 2P+E Socket With Spring Locked Cover A One No. 32A 3 Pin 2P+E Plug Conforming To Iec 309/1&2 And 200A. Alum Inium Bus-Bar For Two Positive & One Negative Should Be Fixed On Fiber Sheet With Pvc Sleeve Colour Code D. B Mccb & Mcb Should Be Operated Without Opening The Front Cover Inter- Connection With Suitable Siz E Pvc Insulated Copper Conductor Cable Conforming To Is:694/1990 From Bus Bar To Mccb/Mcb To Socket. 3 Core & 4 Core Pvc Insu- Lated And Pvc Sheathed Copper Conductor Flexible Cable Up To 110 V-Shall Be Co Nfirmed To Is:694 With Plugs. Proper Visible Indication Plate Fluorescent Screen Printed On The Front Of Both C Ompartments Shall Be Provided For 415V. Ac Pre-Cooling Box And 110V Dc Battery Charging Box As Approved By Railway. Cthe Box Shall Be Grouted In Ground With Cement Morter Mixing 1:2:4 With Muffing As Per Rail Way Drawing. Note:- It Should Be Ensured: 1 All Cable Connections To Be Db S J.Box Panel Etc. Should Be M Ade Through Proper Size Of Cable Glands/End No Space Should Be Left Open To Avoid Entry Of Insect S/Lizards Etc. If Necessary, Blanking Plate Should Be Provided In Dbj. 2 Flexible/Rigid Conduits Wherever Provi Ded Should Be With Suitable End /Clamps Conduit Should Be Secured On Surface Through Suitable Clamps At Regular Interval As Per Is Spec. 3 Sitc As Per Attached Drawing. Warranty Period: 30 Months After The Date O F Delivery

Location
Uttar Pradesh
Due Date
07 May, 2024
Amount
Refer Document
Ref. No #31625569 Central Government/Public Sector Live   GeM Tender

Supply Of Spares -1.5 Sq.Mm Of Single Core Multi Strand Fr-Lsh Pvc Insulated Industrial Grade Copper Conductor Unsheathed Flexible Cables, 1100 Volt Conforming To Is 694., 2.5 Sqmm. Single Core Multi Strand Fr-Lsh Pvc Insulated Industrial Grade Copper Conductor Unsheathed Flexible Cables, 1100 Volt Conforming To Is 694., 4.0 Sqmm. Single Core Multi Strand Fr-Lsh Pvc Insulated Industrial Grade Copper Conductor Unsheathed Flexible Cables, 1100 Volt Conforming To Is 694 ., 3Cx1.5 Sq.Mm Frls Pvc Insulated And Pvc Sheathed, Multicore, Multi Strand Annealed Bare Copper Conductor Flexible Industrial Cable For Voltage Grade 1100 Volt, Conforming To Is 694. , 3Cx2.5 Sq.Mm Frls Pvc Insulated And Pvc Sheathed, Multicore, Multi Strand Annealed Bare Copper Conductor Flexible Industrial Cable For Voltage Grade 1100 Volt, Conforming To Is 694 . , 3Cx4 Sq.Mm Frls Pvc Insulated And Pvc Sheathed, Multicore, Multi Strand Annealed Bare Copper Conductor Flexible Industrial Cable For Voltage Grade 1100 Volt, Conforming To Is 694 . , 6A To 32A Rating, 240/415V, 10Ka, C Curve Miniature Circuit Breaker Suitable For Inductive Load Of Single In The Existing Mcb Db As Required., 6A To 32A Rating, 240/415V, 10Ka, C Curve Miniature Circuit Breaker Suitable For Inductive Load Of Double Suitable For Existing Mcb Db As Required., 6A To 32A Rating, 240/415V, 10Ka, C Curve Miniature Circuit Breaker Suitable For Inductive Load Of Triple Suitable For The Existing Mcb Db As Required., 6A To 32A Rating, 240/415V, 10Ka, C Curve Miniature Circuit Breaker Suitable For Inductive Load Of Triple And Neutral Suitable For The Existing Mcb Db As Required., 40A Rating, Four , 415V, 50Hz Isolator Suitable For The Existing Mcb Db As Required., 63A Rating, Four , 415V, 50Hz Isolator Suitable For The Existing Mcb Db As Required., 25A Rating, Double Single Phase And Neutral, 240V Residual Current Circuit Breaker Rccb Having A Sensitivity Current 30Ma Suitable For The Existing Mcb Db As Required., 40A Rating, Double Single Phase And Neutral, 240V Residual Current Circuit Breaker Rccb Having A Sensitivity Current 30Ma Suitable For The Existing Mcb Db As Required., 63A Rating, Double Single Phase And Neutral, 240V Residual Current Circuit Breaker Rccb Having A Sensitivity Current 30Ma Suitable For The Existing Mcb Db As Required., Suitable Size Gi Box With Modular Plate And Cover Including Providing 1 No.3 Pin 5/6A Modular Socket Outlet And 1 No. 5/6A Modular Switch Etc. Complete As Required., Suitable Size Gi Box With Modular Plate And Cover Including Providing 1 No.6 Pin 5/6A & 15/16A Modular Socket Outlet And 1 No. 15/16A Modular Switch Etc. Complete As Required., Heavy Duty Pvc Casing Capping- Casing Bearing Isi Mark Of Size- 20Mmx12mm, Heavy Duty Pvc Casing Capping- Casing Bearing Isi Mark Of Size- 25Mmx16mm, 5/6 Amp Switch Modular Type Switch/Socket For The Existing Modular Plate & Switch Box Etc. Complete As Required., 15/16 Amp Switch Modular Type Switch/Socket For The Existing Modular Plate & Switch Box Etc. Complete As Required., 3 Pin 5/6 Amp Socket Outlet Modular Type Switch/Socket For The Existing Modular Plate & Switch Box Etc. Complete As Required., 6 Pin 15/16 Amp Socket Outlet Modular Type Switch/Socket For The Existing Modular Plate & Switch Box Etc. Complete As Required., Call Bell Suitable For Single Phase, 230V Complete As Required At Site., 2X2 Feet 36 W Led Light Fixture Recess Type Suitable For Operation On Single Phase 230V, 50Hz Power Supply Complete As Required As Per Enclosed Technical Specification ., 3- Pin, 5/6 Amp Isi Marked Plug Top Suitable For Operation On Single Phase 230V, 50Hz Power Supply., 3- Pin, 15/16 Amp Isi Marked Plug Top Suitable For Operation On Single Phase 230V, 50Hz Power Supply., Red Outer Lens For Rwy End Light Suitable For Existing Airfield Ground Lighting System Agl Complete As Required . Existing Light Fixture Is Of Vardhman Make, Green Outer Lens For Rwy Threshold Light Suitable For Existing Airfield Ground Lighting System Agl Complete As Required . Existing Light Fixture Is Of Vardhman Make, Yellow Filter For Runway Edge Light Suitable For Existing Airfield Ground Lighting System Agl Complete As Required . Existing Light Fixture Is Of Vardhman Make, 5 Kv Grade Plug & Receptacle Type-I Suitable For Single Core 6 Sqmm Airfield Cable Complete As Required ., 150W, 6.6/6.6A Halogen Lamp Pk30d64361 Hlx-Z, Make -Osram Or Equivalent Suitable For Existing Agl/ Cat-I Complete As Required ., 200W, 6.6/6.6A Halogen Lamp Pk30d64382 Hlx-C Make - Osram Or Equivalent Suitable For Existing Agl/ Cat-I Complete As Required ., Isolating Transformer Of 15 Watts, 6.6A/6.6A, 5Kv, 50Hz Suitable For Existing Agl/Cat-I Light Fixtures Complete As Required, Isolating Transformer Of 45 Watts, 6.6A/6.6A, 5Kv, 50Hz Suitable For Existing Agl/Cat-I Light Fixtures Complete As Required, Isolating Transformer Of 100 Watts, 6.6A/6.6A, 5Kv, 50 Hz Suitable For Existing Agl/Cat-I Light Fixtures Complete As Required, Isolating Transformer Of 150 Watts, 6.6A/6.6A, 5Kv, 50 Hz, Suitable For Existing Agl/Cat-I Light Fixtures Complete As Required, Isolating Transformer Of 200 Watts, 6.6A/6.6A, 5Kv, 50 Hz Suitable For Existing Agl/Cat-I Light Fixtures Complete As Required, Beacon Lamp Of 1000W Par64 Ffp 120Vac Or Equivalent Suitable For Existing Becon Light Fixture Complete As Required., Cable Jointing Kit For 1X6 Sqmm Afl Cable Complete As Required ., Hrc High Speed Fuse-Semi Conductor Protection Fuse-Bs88 Type, 100Fe, 100A Rating, Voltage 690Vac, Breaking Capacity 200 Ka Suitable For Existing Switch Gear Make-Bussmann Series Eaton Or Equivalent For Electrical And Agl And Cat I Lighting System

Location
Uttar Pradesh
Due Date
29 Apr, 2024
Amount
Refer Document