Supply of Led Type Indicator Compact Led Pilot Light, Colour : Red, Green, White, Amber Dia. 22.5 Mm, 24 V Dc, Suitable For Lhb Power Car And Lslrd Switch Board Cabinet. Make:- L&T- Esbee Part No. Red-Eplr02 4C Led Ind, Green-Eplg024c Led Ind, White-Eplw024a Led Ind, Amber-Epla024c Led Ind Or Equivale Nt Make C&S Or Siemens Or Teknic Or Ge.Red Colour 40 Nos. Green Colour 40 Nos. White Color 40 Nos. Amb Er Colour 40 Nos. Warranty Period: 30 Months After The Date Of Delivery
Procurement Of Festo Spares -Solenoid Valve Jmfh-5/2-D-3-C, Proximity Switch Smeo-1-Led-24-B, Pilot Operated, Power Cylinder For Hag/Cag Stage-1 Boiler
Supply of Rotary Cam Switch, Off On Position, 2 Pole, 690V Ac 50/60Hz, 16A At 415V Ac -23A, 415V 7.5 Kw 13A, Similar To Make: Salzer Model No.16A-S16-61002-Scb13-Fhyr, Cat No.61002Scb13fhyr Confor Ming To Iec 60947-3 Suitable For Fitment In Lhb Power Car Switch Board Cabinet. Make: Salzer, Siemens, Abb, L &Tsazler Or Similar Warranty Period: 30 Months After The Date Of Delivery Rotary Cam Switch, 4 Position, 6 Pole Without Off, 1000V Ac 50/60Hz, 25A At 415Vm 16A At 1000V Similar To M/S Salzer Model No.25A-S25-74171-B03-Fhyr;Cat No.74171Seb03fhyr Ac 21A, 690V-25A, Ac 23A, 415Vm 11Kw-19A, 16A/1000V, 25A/415V To Conform Iec-60947-3, Suitable For Fitment In Lhb Power Car S Witch Board Cabinet, Make: Salzer,, Siemens, Abb Or Similar Warranty Period: 30 Months After The Date Of D Elivery
Supply of A Switched Mode Power Supplysmps As Per Attached Specifications Q3
Supply Of Material -P.P Reel Insulator -Must Be Of Virgin Plastic Material. Polypropylene Or Equivalent With Break Down Voltage Of 15 Kv, Strain Insulator-Must Of Poly Polypropylene Plastic Rated For 15Kv Uv Stabilized, Corner Post Gi- 8 Ft., Gi-2, 14 Guage Thickness, Painted Having Diametrically Opposite Holes Of Size 6 Mm At Required Interval Of Fencing Installation, Intermediate Post T Angle Post 8 Feet Painted 25Mmx25mmx3mm Having Holes Of Size 6 Mm At Required Intervels Of Fencing Instllation, Supporting Post 6 Feet Gi 1 Inch 14 Guage Thickness Painted, Stay T Angle 2 Feet Painted 25 Mmx25mm X 3Mm, 12 Swg Ht Wire 12 Guage 2.5 Mm Dia High Tensile Wire With Sink Coating For Use As Conducting Wire Winding Strain Insulator, 14 Swg Binding Wire-High Quality Zinc Coating Wire For Binding Reel Insulators, Tighing Support Post With Corner Post, Wire Tightner-Permanant Wire Tighter Made Of Special Aluminium Alloy Designed For Kv, Uv Stabilized, Joint Clamp With Nut And Bolt- Supply Of Joint Clamp With Nuts And Bolt Gi Galavanized Coating For Fastening Conducting Wire Around Posts, Hot Dipped Galvanised , Earth Rod-Copper Plated Earth Rod 14 Mm -3 Ft. Length, Earthing Compound 8 Kg, Tension Spring Spring Steel Cable Of Making Compresion Loads, Galvanised 15Cm Length, Withstand 400Kg , Gate Handle-Steel Rope With Handle And Spring Assembly. Handle Made Of Polyethylene, Lead Out Cable For Fence System Double Insulated Gi Cable Inner Core Wire 2 Sq.Mm. Hot Dipped Galvanised Steel Core, Capable Of With, Standing 15Kv Should Be Provided To Prevent Bimetal Salt Formation At Connections, Single Core 2.5 Mm Sq. Cable-2.5 Mm² Single Core Copper Cable For Connecting The Solar Panel To The Tubular Battery Through Charge Control Unit With Required Terminal Sockets, Nut And Bolt, Washer, Lightining Diverter -15Kv-50Kv Rod Gap Arrester, Must Be Capable Of Diverting Stray Lightning And Adjustable For Spark Gaps Adequate Earthing To Be Provided, 100 Watt Solar Panel- 100 Watt/ 12 Volt And Above Poly Crystalline With 10 Year Warranty Having Iec/Mnre Certification, Charge Control Unit-20 A 12/24 V Pwm Charge Controller Unit Of Standard Make Suitable To Control The Charging Of The Tubular Battery Energizer With 10 Kv Output Safety Standards To Be Followed Are Bis 302-2-76 Iec60335-2-76. Switch-High, Medium And Low Power Setting. Fence Alarm System Covering Area Of 1.5 Km, Solar Panel Supporting Stand With Metal Box Painted For Battery And Energiser - 18 Guage Thickness Metal Boxlockable - Painted. Gi-Sheet, Painted Should Be Capable Of Housing Batterry, Charge Controller And Energizer And Fixed With Required Clamps And Nut And Bolt On Solar Panel Support Stand Made Of Gi Pipe Of 50Mm Diameter And B Class Type With Suitable Arrangement For Holding The Panel Warning Sign-Polyethylene Plastic With Satuatory Warning With Sign, Tubular Battery 12 V, 100Ah- 12 V, 100 Ah C10 Rating With Full 5 Year Replacement Warranty Tower Battery For Energising The Energiser, Digital Volt Meter- Must Display Fence Voltage Digitally Upto 15Kv . Made Of Non Shocking Plastic, Tool Kit Consisting Of Wire Tighterner Rod, Double Headed Spanner, High Tensile Wire Cutter And Cutting Plier For Installation Of New 5 Line Solar Power Fence
Repair And Maintenance Of Plant Systems equipments - Industry Unit; Hvac Substation Switch yard Electrical System Or Installation Power House Equipment; Service Provider
Procurement Of Spares Of M/S Eandh Make Instruments -Neucleonic Density Meter, Level Switch, Transmitter, Flow, Pcb Card, Power Unit For Level Transmitter, Antenna Fmr57 , Sensor , Display Module Proline 300, I/O Module, Slot 1, Proline 300, Display Module A401 Promass 10, Io Module Promag 10, Electronics Micropilot, Horn Etc
Supply of Knob For Rotary Switch 16Amps, 4Mm Pentagon Spindle Type, Flag Handle For 16A Similar To Salz Er Part No Knfhs2 Or S16/Tp16/Rt16 Make Salzer L&T, Siemens, Ge, Aeg Only. Oem Or Their Authorized D Ealers Or Suppliers With Tender-Specific Authorization Letters From Ome Only To Quote With Documentary Evidence. Warranty Period: 30 Months After The Date Of Delivery Rotary Switch 9 Pole - 3 Way Multistep Switch Without Off 16A Similar In All Respect To Model - 16A- S16- 61126-B03-Tdyr Ic 60947-3 Of Salzer Make For Use In Power Car For Selection Hog, Dg, Bus Coupler M Ake/Brand:-Salzer L&T, Siemens, Ge, Aeg Only. Oem Or Their Authorized Dealers Or Suppliers With Tender- Specific Authorization Letters From Ome Only To Quote With Documentary Evidence. Warranty Period: 30 Months After The Date Of Delivery Rotary Switch Conforming To Salzer Makes 16A-S16-61121-B03-Tdyr. For Use In Power Car Fo R As Plant Selector Switch A, B, A+B, Off Accepted Make :-Salzer L&T, Siemens, Ge, Aeg Only. Oem Or Their Authorized Dealers Or Suppliers With Tender-Specific Authorization Letters From Ome Only To Quote With Documentar Y Evidence. Warranty Period: 30 Months After The Date Of Delivery Rotary Switch Conforming To Salzer Makes 25A-D25-61198-B03-Fhyrm. For Use In Power Car For As Dc Isolating Switch Accepted Make - Salzer L&T, Siemens, Ge, Aeg Only. Oem Or Their Authorized De Alers Or Suppliers With Tender-Specific Authorization Letters From Ome Only To Quote With Documentary Evidence. Warranty Period: 30 Months After The Date Of Delivery Rotary Switch 16A, 750 V Ac, 50 Hz, Conforming To Edts-103, Rev-D, Am-6. As Per Salzer Ma Ke 16A-S16-61153-B03-Tdyr. Accepted Make:- Salzer L&T, Siemens, Ge, Aeg Only. Oem Or Their Authoriz Ed Dealers Or Suppliers With Tender-Specific Authorization Letters From Ome Only To Quote With Documentary Evide Nce. Warranty Period: 30 Months After The Date Of Delivery Rotary Switch 2 Position, 2 Pole, 16A, Conforming To Salzer Make Cat No.16A-S16-61197-B03-T Dyr For Use In Power Car For Convertor On-Off, Accepted Make - Salzer L&T, Siemens, Ge, Aeg Only. Oe M Or Their Authorized Dealers Or Suppliers With Tender-Specific Authorization Letters From Ome Only To Quote With D Ocumentary Evidence. Warranty Period: 30 Months After The Date Of Delivery
Installation And Commissioning Of Cctv With All Accessories - Cctv Dome, Cctv Bullet, Nvr With 4 Hdd Support, Giga Switch With Non Poe, Giga Switch With 2 Uplink Giga, Survelliance Hdd, Poe, Wall Mount Rack, Mount Box, Electrical Power Box, Connector, Cable, Power Cable, Pvc With Accessories, Wire Laying Charges, Installation Charges, Lde Monitor
Supply Of Arduino Uno, Arduino Nano, Arduino Maga, Breadboards, Rechargable Battery Set With Charger, Berg Strips, Water Pump Module, Bluetooth Module, Gsm, Gps, Motor Driver Module, Alligator Connectors, Jumper Cable, Button Switch Set Of Different Type, Ir Sensors, Pir Motion Detectior Module, Temperature Sensor, Power Bank, Dc Motor, Servo Motors, Servo Motor Tester, Stepper Motor With Driver Board, Glue Sticks
Supply of Switch Pressure To Cummins Part No: 4359612 For Lhb Power Car. Make / Bran D : Cummins Warranty Period: 30 Months After The Date Of Delivery Switch Pressure To Cummins Part No: 2897691 For Lhb Power Car. Make / Bran D : Cummins Warranty Period: 30 Months After The Date Of Delivery
Supply of Mini Hinge With Nut Plate For Mini Hinge As Per Dirak Part No. 218-9501 And 218-0907.15 Or Arih Ant Ahg 361 And Back Plate Or Equivalent Suitable To Be Installed In Door Leaves Of Switch Board Cabinet Of Hog/Eog Lhb Ac Coaches As Per Specification No. Rdso/Pe/Spec/Ac/0192-2018 Rev. 1. Accepted Mak E - Dirak /Hafale/ Southco / Arihant / Darshana Or Similar. Warranty Period: 30 Months After The Date Of Deliver Y Profile Hinge 95 Mm For Switch Board Cabinet S1 Of Lhb Ac Coaches As Per Dirak Part No: 24 2-9103.00-00000 Or Hafele Make, As Per Bill Of Material Bom For Switch Board Cabinet Of Rdso Spec No: Rdso/Pe/Spec/Ac/0184-2015 Rev.0 Or Latest. Accepted Make/Brand: Dirak/Southco/Hafale/Ari Hant/Darshana Or Similar. Warranty Period: 30 Months After The Date Of Delivery Finger Pull Suitable For Snap Lock With Push Button For Lhb Ac Power Panel As Per Dirak Part No: 370-0463.03-04703 Or Exactly Similar In Hafele Make, As Per Bill Of Materials Bom For Switch Board Cabinet S1 Of Rdso Spec. No: Rdso/Pe/Spec/Ac/0184-2015 Rev.0. Accepted Make/Brand: Dirak/Sout Hco/Hafale/Arihant/Darshana Or Similar. Warranty Period: 30 Months After The Date Of Delivery
Supply of Working And Non Working Net 1 & 2 Power Contactor, S2k4, S2k5, S2k6, S2k7, 3 Pole, 1000 V A C Operational Voltage, 50Hz, Suitable For 100 Kva, 750 V Ac, On Load Switching Under Ac-6A Category At Tempe Rature Of 70 Degree C & Coil Voltage Of 110V+25%-30% Dc At Temperature Of 70 Degree C With Surge Suppressor, Aux. Contacts: 2No+ 2Nc, As Per Rdso Spec Specification No, Rdso/Pe/Spec/Tl/ 0195-2019 Rev-0 Or Late St, Make-Abb Model No Af190b-30-22Rt-12, Siemens Model No 3Rt10566la068k +3Rt19555af318k, L& T Model No Mo140, Schneider Model No.Lc1d115fd, C&S Electric Model No. Lc1f-Dp225afd +La9d 009 980 Only. Warranty Period: 30 Months After The Date Of Delivery
Supply of Feeders - 1 & 2 And Bus Coupler Power Contactors, 3 Pole, 1000V Ac, 50Hz, Suitable For 500 Kv A, 750V Ac On Load Switching Under Ac-6A Category At Temperature Of 70 Degree Celsius & Coil Voltage Of 110V +25%- 30% Dc With Surge Suppressor, 2No+2Nc. As Per Rdso Spec. No. Rdso/Pe/Spec/Tl/0195-2019 R Ev.-0 For Switch Board Cabinet Of Hog Complaint Lslrd Coaches, Make Abb Af1250-30-11, L&T Mvo 820, Seimens 3 Tf69338df4za02 + 3Tx75723h, L&T Mv0820 Warranty Period: 30 Months After The Date Of Deli Very
Supply, Installation, Testing, Commissioning Of Modular Workstation And Power Backup System - Single Slide Workstation, Back To Back Workstation, Metal Kbpt, Cpu Trolley, Revolving Chair, L2 Managable 48Port 1Gig Switch, Cat6 Cable, Fully Loaded Patch Panel, Patch Cord Cu Cl C6 U Gy 1Mtr, Patch Cord Cu Cl C6 U Gy0.5Mtr, Back Boxes, 2Port Face Plate, Cat6utp Rj45 Info. Outlet, Green, Face Plate Side, 12U Rack, Pvc Casing And Caping Pvc, Services - Cabling Installation, Services - Patch Panels, Services - 48Port 1Gig, Services - I Os Back Box Face Plate I O, Rack Installation, Electrical Layout, 20Kva 3Phase In 1Phase Out, With True Onlibe Double Convention Ups With 12C-32Unitsof 100Ah Smf Battery Of Quanta Or Exide, Sitc Of All The Above Modular Workstation And Power Backup System
Supply Of Electrician Tools And Equipment - Digital Multi Meter, Ac Voltmeter Mi Analog Portable Box, Milli Voltmeter Centre Zero Analog Portable, Ammeter Mc Analog Portable Box Type, Ac Ammeter Mi Analog Portable Box Type, Digital Wattmeter, Ac Energy Meter 1 Phase, Ac Energy Meter 3 Phase, Power Factor Meter Digital, Magnetic Flux Meter, Tachometer Analog, Tachometer Digital, Tong Tester Clamp Meter, Megger, Thermometer Digital, Ohm Meter Series Type, Ohm Meter Shunt Type, Hydrometer, Miniature Circuit Breaker, Mccb, Elcb And Rccb, Bus Bar With Brackets, Rubber Matting, Electrician Helmet, Rcc Pole With Accessories, Dc Starter4point, Motor Generator, Ac Squirrel Cage Motor, Synchronous Motor, Stepper Motor With Digital Controller, Shaded Pole Motor, Wheat Stone Bridge With Galvanometer And Battery, Oscilloscope Dual Trace, Temperature Controlled Soldering Iron, Discrete Component Trainer, Electric Induction Plate, Ac Ceiling Fan And Ac Table Fan, Mixture And Grinder, Washing Machine Semiautomatic, Pillar Electric Drill Machine Motorized, Motorised Bench Grinder, Manual Motor Coil Winding Machine, Ceiling Fan Coil Winding Machine, Primary Current Injection, Inverter With Battery, Safety Belt, Series Test Lamp, Earth Plate, Earth Electrode, Pin Type Shackle Type Egg Type Suspension Type Insulators, Solar Panel With Battery, Motor Pump, Ev Charger 3 Phase, Ev Charger 1 Phase, Smart Meter, Plug Socket Piano Switch Lamp Holder, Screwdriver Insulated 6Mm, Screw Driver Insulated 4Mm, Electrician Screwdriver Thin Stem Insulated Handle, Heavy Duty Screwdriver Insulated, Electrician Screwdriver Thin Stem Insulated Handle, Neon Tester, Combination Plier Insulated, Pliers Long Nose Insulated, Pliers Round Nose Insulated, Pliers Flat Nose Insulated, Spanner Adjustable Drop Forged Ss, Outside Calliper, Inside Calliper, Divider, Hammer Cross Peen With Handle, Punch Centre, Pipe Vice Cast Iron With Hardenedjaw Open Type, Pully Puller With 3 Legs, Bearing Puller Inside And Outside, Crimping Tool 25Mm, Crimping Tool 16Mm, Knife Double Bladed Electrician, Scissors Blade Ss, Wire Cutter And Stripper, Drill Ss Twist Block, Smoothing Cutters, Measuring Steel Tape, Steel Rule Graduated Both In Metric And English Unit, Gauge Wire Imperial Stainlees Steel, Sewing Machine, Double Needle Machine, Button Hole Machine, Button Sewing Machine, Bar Tack Machine, Feed Off The Arm Double Needle, Zig Zag Multipurpose Machine, Electric Automatic Steam Press, Measuring Tape, Scale Plastic, Tailors Card Scale Triangular, Tailors Squareplastic, French Curve Of Three, Leg Shaper Plastic, Seam Ripper, Thimble, Thread Cutter, Scissors 25 Cm, Garment Hangers, Pattern Punch, Stand For Hanging Dresses, Students Chairs With Writing Pads
Facility Management Service- Manpower Based Version 2 - Industrial; Cleaning Sweeping Of Power House Complex Switchyard Sanjpoi Store And Running Of Power House Canteen For Cpsi; Unskilled Facility Management Service- Manpower Based Version 2 - Industrial; Cleaning Sweeping Of Power House Complex Switchyard Sanjpoi Store And Running Of Power House Canteen For Cpsi; Semi-Skilled
Supply of Actuator Spares, 76 Power Module Complete 1 Power Module Complete 2 Control Module Complete 1 Control Module Complete 2 Selector Switch Push Button Assembly Thrust Bearing With Race Hand Wheel Thrust Bearing With Race Sa12 Sa15 Thrust Bearing With Race Sa3 Sa6 Bush Base Housing Sa100 Bush Base Housing Sa50
Supply of Power Supply On/Off Switchs01 To Siemens Model No.3Sb50002ab01+3Sb54000e, L&T Mod El No.Emncsk1+Ec1c, Schneider Model No.Xb5ad21n+Zbe101n+Zbe102n, Abb Model No.M2ss2-10B+ Mcbh-00+Mcb-10 And Teknic Only Acceptable For Lhb Ac Switch Board Cabinet As Per Rdso Spec No.Rdso /Pe/Spec/0184-2015 Rev 1 Warranty Period: 30 Months After The Date Of Delivery
Procurement Of Lt Switchgear Spares -Xfmr, Curr, 200/1A, 15Va, Cl-1/5P20, Xfmr, Curr, 150/1A, 0.415/0.66Kv, 7.5Va, Cl-1, Xfmr, Curr, Metering, Wpl, Resin Cast, 100/1A, Xfmr, Curr, 75/1A, 7.5Va, Cl-1, L&T:Fn315/400/630/800 Hndl Asy-B:Sk91279, Mcc:L&T:Fn-200/250 Handle Assy.-B, Mcc:L&T:Fn-32/63 Handle Assy.- Ce, L&T:Handle Assy-A For Fn125:Sk912580000, Xfmr, Pot, 415/110V, 50Va, Cl-1, Xfmr, Pot, 415Vr3/110Vr3, 50Va, Cl-1, Xfmr, Curr, Ring, Resin Cast, 3000/1A, Cl-Ps, Xfmr, Curr, 3000/1A, 0.415/0.66Kv, 7.5Va, Xfmr, Curr, Resin Cast, 1000/1A, Cl-Ps, Xfmr, Curr, 1000/1A, 0.415/0.66Kv, 7.5Va, Xfmr, Curr, 630/1A, 0.415/0.66Kv, 7.5Va, Power Contctr.: 3P, 110Vac, L&T-Mnx18, Pwr.Contctr.: 3P, 110Vac, 110Vac, L&T-Mnx32, Powr Contr:3P415vac:110Vac:L&T:Mnx70, Power Contctr.: 3P, 110Vac, L&T-Mnx110, Power Contactor Mnx225, 415 Volts, Ac3, , Contactor, Power, 415Vac, 400A, 3P, L&T, Coil, Cs94142, L&T, Contactor, Mnx265, Contact Block 1No+1Nc, 2Nd Left-#Cs94207, Contact Block 1No+1Nc-Second Right-Cs942, Side Add On Lhs, 1No+1Nc For Mnx9-40, Cs94, Side Add On Rhs, 1No+1Nc For Mnx9-40, Cs94, Switch Disconnector Fuse Tpn Fn125 L&T, Switch Disconnector Fuse Tpn, Fn250 L&T, Switch Disconnector Fuse Tpn Fn400 L&T, S/W Rotry Waf:4 Way:440V Ac, 32A:Salzer, Rotry Waf S/W On/Off 240Vac 25A Salzer, O/L Mn12l 66-110A, L&T Make, Selectr.Switch: 4-Posn, 16A, 220Vdc;Salzer, S/W Sel:On / Off:16A 220Vdc:Salzer, S/W Sel:2:Pos:16A, 240Vac:Salzer, S/W Rotry Waf:4 Way:660V Dc, 25A:Salzer, Racking Nut For L&T Module, O/L Relay Type Mn2 L&T 0.9-1.5 A, Relay, Thermal O/L, 0.6-1A, Mn2, L&T, Thermal Bi-Metal O/L Relay:Mn2, 0.3-0.5A, Bimetal O/L Relay Type Mn2 Range4.5-7.5A, Thermal Overload Relay:A1.4-2.8, 6-10Amp Over Load Relay L&T Make, Rely Th O/L:14-25 A:L&T Make Mn2, O/L Relay L&T Mn2; 9-15A Singleeph.Prot., Overload Relay Range : 3-5A, Type:Mn2, Thermalo/Lrlymn12, 135A -225A, Ss94138, L&T, Ct Opr Bim;90-150A;Mn12;L&T-Ss94138oomo, Pulling Handle, Sk 91185, L&T, Right Micro Switch For L&T Make Acb, Left Micro Switch For L&T Acb, Microswitch Test/Isolate Position Right, Microswitch Test/Isolate Position Left, Charging Motor, Sl00347oooo, L&T, Closing Coil 220V Dc For L&T Make Bkr., Shunt Release Ea 220V Dc 501-30-98266, Frcd For L&T Make Cn-Cs 4000A Edo, Resistor Kit 220 V D.C.For L&T Acb, Racking Interlock For L&T Breaker, Bezel For C-Pwr.Brkr-1250A, #Sl916020000, Elect Position Indication For L&T Acb, Panel Door Ingress Seal, D/Out Acb, Stablsng Resstr Varabl 0-2000Ohm200w 1A, Lock A Type For L&T Acb Rackout Locking, Cam Lock For Doors Of L&T Switch Gear, Door Interlock For L&T Make Acb, Lt Air Circut Breaker Key Lock T-Aklaf12, Reset Cord For Over Load Relay, Lt Swtch Gr:Reset Cord 1Metre Long, Kit Mount Mn2 Relay Onn Ml0/1/1.5 , 6 Way Sic Block Cat No. Sl92701; L&T, Sec Isoltng Conts+Tbrak-F/M L&T Make, Sec Isoltng Conts+Tserv-F/M L&T Make, Sec Iso Cont Serv Sa92567 For Lt S/G, L&T-Sec Iso Contact Male - Sa92565, Racking Handle Of L&T Modules, Racking Handle For L&T Acb, Aux Cont Kit Typ Fn315 C No.Sk91330 L&T, Aux Cont Kit Typ Fn200/250 C No.Sk91329, Aux Cont Kit Fn100/125/160C No.Sk91328, Auxiliary Contact Kit For Fn63, Aux Contr:L&T:Add On Block-Cs94112, Aux Contr: L&T-Add On Block, Cat-Cs94113, Aux Contr: L&T-Add On Block-Cs94114, Aux Contr: L&T-Add On Block-Cs94120, F, Aux Contactor: L&T-Add On Block-Cs94121, Contactor, Auxiliary, 110Vdc, 6A, 2No+2Nc, Frcd, For, 1250 /2500/4000A, Acb, Spare Kit L&T Make For Mnx110 Contactor, Spare Kit Without Coil Mnx225 Cat-94157, Spare Kit Without Coil Mnx400 Cat-94161, Powr Contr:2P 22Vdc:Cv 220Vdc:200A, Spring Charging Assy, Sl90686oooo, L&T, Front Facia- For Electrical Acb, Sl93202, 220 V Dc Spring Charge L/Switch Assy, L&T