Supply Of Material -P.P Reel Insulator -Must Be Of Virgin Plastic Material. Polypropylene Or Equivalent With Break Down Voltage Of 15 Kv, Strain Insulator-Must Of Poly Polypropylene Plastic Rated For 15Kv Uv Stabilized, Corner Post Gi- 8 Ft., Gi-2, 14 Guage Thickness, Painted Having Diametrically Opposite Holes Of Size 6 Mm At Required Interval Of Fencing Installation, Intermediate Post T Angle Post 8 Feet Painted 25Mmx25mmx3mm Having Holes Of Size 6 Mm At Required Intervels Of Fencing Instllation, Supporting Post 6 Feet Gi 1 Inch 14 Guage Thickness Painted, Stay T Angle 2 Feet Painted 25 Mmx25mm X 3Mm, 12 Swg Ht Wire 12 Guage 2.5 Mm Dia High Tensile Wire With Sink Coating For Use As Conducting Wire Winding Strain Insulator, 14 Swg Binding Wire-High Quality Zinc Coating Wire For Binding Reel Insulators, Tighing Support Post With Corner Post, Wire Tightner-Permanant Wire Tighter Made Of Special Aluminium Alloy Designed For Kv, Uv Stabilized, Joint Clamp With Nut And Bolt- Supply Of Joint Clamp With Nuts And Bolt Gi Galavanized Coating For Fastening Conducting Wire Around Posts, Hot Dipped Galvanised , Earth Rod-Copper Plated Earth Rod 14 Mm -3 Ft. Length, Earthing Compound 8 Kg, Tension Spring Spring Steel Cable Of Making Compresion Loads, Galvanised 15Cm Length, Withstand 400Kg , Gate Handle-Steel Rope With Handle And Spring Assembly. Handle Made Of Polyethylene, Lead Out Cable For Fence System Double Insulated Gi Cable Inner Core Wire 2 Sq.Mm. Hot Dipped Galvanised Steel Core, Capable Of With, Standing 15Kv Should Be Provided To Prevent Bimetal Salt Formation At Connections, Single Core 2.5 Mm Sq. Cable-2.5 Mm² Single Core Copper Cable For Connecting The Solar Panel To The Tubular Battery Through Charge Control Unit With Required Terminal Sockets, Nut And Bolt, Washer, Lightining Diverter -15Kv-50Kv Rod Gap Arrester, Must Be Capable Of Diverting Stray Lightning And Adjustable For Spark Gaps Adequate Earthing To Be Provided, 100 Watt Solar Panel- 100 Watt/ 12 Volt And Above Poly Crystalline With 10 Year Warranty Having Iec/Mnre Certification, Charge Control Unit-20 A 12/24 V Pwm Charge Controller Unit Of Standard Make Suitable To Control The Charging Of The Tubular Battery Energizer With 10 Kv Output Safety Standards To Be Followed Are Bis 302-2-76 Iec60335-2-76. Switch-High, Medium And Low Power Setting. Fence Alarm System Covering Area Of 1.5 Km, Solar Panel Supporting Stand With Metal Box Painted For Battery And Energiser - 18 Guage Thickness Metal Boxlockable - Painted. Gi-Sheet, Painted Should Be Capable Of Housing Batterry, Charge Controller And Energizer And Fixed With Required Clamps And Nut And Bolt On Solar Panel Support Stand Made Of Gi Pipe Of 50Mm Diameter And B Class Type With Suitable Arrangement For Holding The Panel Warning Sign-Polyethylene Plastic With Satuatory Warning With Sign, Tubular Battery 12 V, 100Ah- 12 V, 100 Ah C10 Rating With Full 5 Year Replacement Warranty Tower Battery For Energising The Energiser, Digital Volt Meter- Must Display Fence Voltage Digitally Upto 15Kv . Made Of Non Shocking Plastic, Tool Kit Consisting Of Wire Tighterner Rod, Double Headed Spanner, High Tensile Wire Cutter And Cutting Plier For Installation Of New 5 Line Solar Power Fence
Bengaluru - Dharmavaram Section : Provision Of Safety Fencing With W-Beam Metal Barriers Along Side The Track For A Length Of 63.4 Km In Connection With The Work Of Increasing Sectional Speed From 110 Kmph To 130 Kmph. Maintenance Period Is 12 Months
Provision Of Safety Fencing With W-Beam Metal Barriers Along Side The Track For A Length Of 36.50 Km In Connection With The Work Of Increasing Sectional Speed From 110 Kmph To 130 Kmp. Maintenance Period Is 12 Months
Provision Of Safety Fencing With W-Beam Metal Barriers For A Length Of 79.7Kms In Bangarpet - Jolarpettai Bwt-Jtj Section In Connection With The Work Of Sbc-Jtj - Increasing Sectional Speed From 110Kmph To 130Kmph. Total 120Kms Length. Maintenance Period Is 12 Months
Provision Of Safety Fencing With W-Beam Metal Barriers For A Length Of 40.3Kms In Whitefield - Bangarpet Wfd-Bwt Section In Connection With The Work Of Sbc-Jtj - Increasing Sectional Speed From 110Kmph To 130Kmph. Total 120Kms Length. Maintenance Period Is 12 Months
S &T Work To Faccilitate Construction Of Rcc Boundary Wall / Safety Fencing In Connection With Raising Of Speed Up To 130 Kmph In Nyn-Mkp Seection.
Provision Of Fencing At Trespassing/Safety/Lc Location In Chhapracpr - Bhatnibtt Section
Construction Of Missing Boundary Wall At Colony, Station And Market Area To Prevent Encroachment At Lnl 4.35 Km. B Fencing Along Colony Quarters To Prevent Trespassing Of Animal & For Safety Of Quarter Occupants.