Electrical Work In Connection With Provision Of 1 Lakh Liter Capacity Ug Tank, Pump House Along With Electrical Booster, Sprinkler & Jockey Pump Including Pipe Line Network In Compliance Of Fire Audit Carried Out
Annual Repair And Maintenance Of 320 Kld Sewerage Treatment Plant - Supply Of Bio Culture Of Reputed Firms For Waste Water Management To Reduce Bod Cod Tss As Per The Pcb Norms For Period Of 365 Days 6 Litres Per Day 2190 Ltrs, Supply Of Jeggery Use For Chemical Reaction In Stp To Reduce Bod Cod Tss As Per Pcb Norms For Period Of 365 Days 6 Kgs Per Day 2190 Kg, Supply Of Liquid Chlorine For Period Of 365 Days 6 Litres Per Day 2190 Ltr, Supply Of Decorticated Coil Fiber For Stp 1 Bag 30 Kg, Amc Of 02 Nos Sump Pump 3 Phase 04 Nos 05 Hp And 02 Nos 03 Hp Mono Block Motor 3 Phase Including All Minor Repairs Etc Complete, Operation And Preventive Maintenance Of Stp By One Operator In All Days In A Month, Sample Testing Of Treated Water From Any Nabl Accredited Lab For Following Parameters A Bod B Cod C Tss D Fecal Choliform E Ph, Repairing Of 01 Nos 5 Hp Sump Pump Installed At Stp One Time Repair, Repairing Rewinding And Bearing Of 05 Hp Monoblock Pump Installed At Stp One Time Repair, Repairing Bearing And Sealing Of 03 Hp Monoblock Pump Installed At Stp One Time Repair, Providing And Fixing Of 50 Mm Multi Port Valve For Stp Sludge Water Installed At Stp One Time Repair, Repairing Of Micro Processer Based Stp Panel Installed At Stp One Time Repair, Replacement Of Sprinklers Installed On Chambers For Smooth Functioning Of Stp
Supply Of Sprinkler Qcm Pipe, Hdpe Pipe, Hdpe Sadel, Plug, Hdpe Bend, Hdpe T, Metal Sprinkler, Metal Rizer Pipe, Pump Connection Nipple, 5 Hp Kirlosker Pump, Hdpe, Starter, Plot Stand, Mm Sabmisal Isi Cables
Annual Operation And Maintenance Contract For E And M Installations At Shravasti Airport, Periodical Maintenance And Operation Of Electrical And Mechanical Installations Involving Operation, Repairs And Maintenance, Attending To Complaints/Faults/ Breakdowns And Taking Rectification Action, Ensuring Serviceability/ Satisfactory Working Condition Of The Systems, Carrying-Out Preventive Maintenance, Maintenance Of Records/ Documents Etc Under This Contract For Shift Duty For All 7 Days On All Working Days Including Saturdays, Sundays And Holidays As Per Tender Specifications, Terms & Conditions By Providing/Engaging Of Electrician & Helper. Shift Purpose- Electrician Skilled- 03 No. Per Day For Shift Duty For All 7 Days In A Week. Helper Un-Skilled- 03 No. Per Day For Shift Duty For All 7 Days In A Week., Monthly Visit Of Fire Technician/Engineer Form Oem Of Fda System Or From Oem Authorized Dealer For Carrying Out Healthiness Check Of Fda System, Attending Faults, Carrying Out Preventive Maintenance I/C Cleaning Etc. As Required To Fire Main Panel And Repeater Panels, Detectors, Response Indicators, Mcp Of The Fda System Etc. Making Replacement Of The Spare Parts/Accessories Etc. If Required For Healthiness Of The Fda System And Submission Of Service Report To Eic. Charges Against Labour & Tools Etc. Required For Attending Faults, Preventive Maintenance, Servicing, Replacement/Installations Of Spare Parts And Accessories Are Included In The Item. All Spare Parts/Accessories Required For Healthiness Of Fda System Shall Be Provided By Aai I.E Paid To The Agency Against Supply Of Materials As In Extra Item On Market Rate On Submission Of Original Invoice And Supporting Documents/Price List Of Oem. Inventory Of Fda System- Main Control Panel & Microprocessor Based Analog Addressable - 01 No. Addressable Multi Detector - 60 Nos Addressable Heat Detector - 4 Nos Ri - 39 Nos Mcp - 3 Nos Addressabel Hooter- 4 Nos Fault Isolator- 4 Nos, Maintenance & Up-Keeping Of Fire Extinguishers, Fire Suppression System And Fire Fighting System Installed At Shravasti Airport Inclusive Of Periodical Checking/ Testing, Servicing, Maintaining Records, Attending Break Down Calls Of All Fire Extinguishers, Hydrant Valves, Hoze Boxes, Pipes, Branch Pipes, Hose Reels, Hose Pipes, Sprinklers, Nrvs, Pipe Lines, Pressure Switches, Main Pumps, Jockey Pumps, Booster Pump, Batteries, Starter Panels, Pressure Gauges, Sluice Valves/Gate Valve Etc As Detailed In The Special Conditions Of The Contract, Particular Specification Etc. Complete As Required. Note- This Item Is Only Service And Does Not Cover Material Part. All Spare Parts/Accessories Required For Healthiness Of Fire Fighting System Shall Be Provided By Aai I.E Paid To The Agency Against Supply Of Materials/Repair Of Equipment As In Extra Item On Market Rate On Submission Of Original Invoice And Supporting Documents/Price List Of Oem., Etc
Planning, Designing, Construction, Testing And Commissioning Of Commercial Building Of Rcc Framed Structure Basement 2 + Gf + 6 Floors+ Terrace “Pm Ekta Mall” At Pandri Haat Campus, Pandri, Raipurchhattisgarh Which Meet Green Building Norms And Obtain The Certification Of The Same By Incorporating Stipulated Specification Along With All Services Civil And E&M As Per Nbc- 2016/Cpwd/Cgpwd Specification, Including Site Survey, Soil Investigation, Provision Of Parking Planning And Design Of Required Services, Preparation Of Preliminary Architectural & Detailed Working Drawings, Structural Analysis & Design, Planning, Designing, Execution Of All Civil And E & M Services, Obtaining All Statutory Approvals Including Dismantling Of Existing Building, Cutting/Transplant Of Trees, Environment Clearance/Environment Impact Assessment Eia And Commencement Certificate From Local Body And Commissioning Of Services Etc. As Per Detailed Scope And Specifications For Civil And E & M Works Including Internal Water Supply & Sanitary Installations, Internal Electrical Installations And Fans, External Civil And Electrical Service Connections, Power Wiring, Telephone Conduiting And Wiring, Lightning Conductor System, Lifts, Escalators, Addressable Intelligent Fire Alarm System, Fire Fighting System With Wet Riser And Sprinkler System & Pressurized Mechanical Ventilation I/C Chiller, Illuminated Signage, Lan System, Ip Based Epabx System, Wifi System, Ip Based Cctv System, Façade Lighting, Façade Projection Mapping, Water Supply Pump Sets, Dewatering Pumps And Panels, Online Ups System With 30 Minutes Backup, Dg Set, Integrated Building Management System, Audio -Visual/Conference System, Auditorium, Solar Water Heating System, Compound And Street Lighting With Led, Stp, Horticulture Work Etc And Any Other Component Necessary For Completion, Making The Facilities Functional, Obtaining Fire Clearance, Water Connection, Electrical Connection And Lift From Authorities Concerned, Obtaining Occupancy Certificate/ Building Use Bu Permission From Local Body, Obtaining Green Certification, Preparation And Submission Of “As Built Drawings” And Handing Over Of The Building All Complete As Per Directions Of Engineer-In-Charge Including 1 Year Of Operation And Maintenance & 3 Years Of Defect Liability Period.