Supporting Device Tenders

(Select any tender from the list to send an email)
Ref. No #31685888 Central Government/Public Sector Live

Design, Manufacture And Supply Of Improved High Tensile Tight Lock Cent Re Buffer Coupler With Aar H Type Head, Balanced Draft Gear And Its Associated C Omponents For Fitment On Broad Gauge Passenger Coaches Of Indian Railways As Pe R Rdso Spec.No.Rdso/2011/Cg-03, Rev-03. Coupler Mounting Arrangement On Under Fra Me Shall Be Generally To Icf Drg.No.Lwgfac-2-1-001 Alt E. One Coupler Set Shall Con Sists Of The Following 1.Tight Lock Coupler Head And Associated Components Refe Rence Rdso Approved Firm Drawings-Qty -1 No. 2.Balanced Draft Gear With Pivot Pin Reference Rdso Approved Firm Drawings-Qty 1 No. 3. For Coupler Head With M20 Fasteners Reference Rdso Approved Firm Drawings -Qty 1 No. 4.Manu Al Un Coupling With M12 Fasteners Reference Rdso Approved Firm Drawings - Qty -1 No. 5.Rear Carrier Plate For Draft Gear With M16 Fasteners Reference Rdso Approved Firm Drawings -Qty -1 No. 6.Front Carrier Plate For Draft Gear With M16 Fa Steners Rdso Approved Firm Drawings-Qty -1 No. Special Condition : 1. Maintenance Manu Al In Soft Copy And Hard Copy Shall Be Supplied With Item 2.Necessary Test Certifica Tes As Per Rdso .Specn .No. Rdso/2011/Cg-03, Rev-03 Shall Be Supplied With Item 3. Tende Rer To Submit Rdso Approved Drawings At The Time Of Quoting The Tender. 4. Packing Condition: Items Are To Be Packed In Two Different Boxes As Given Below. I. List Of Ite Ms To Be In Box-1 1. Balanced Draft Gear With Wedge Block Assembly & Wedge Block. 2 . Rear Carrier Plate 3. Fornt Carrier Plate 4. Fasteners For Front And Rear Carrier Plates. Ii. List Of Items To Be In Box-2 1. Coupler Head And Associated Components. 2. M Ain Pivot Pin. 3. For Coupler Head. 4. Fasteners For De Vice. 5. Manual Coupling 6. Fasteners For Manual Uncoupling . 7. Split Pi Ns For Carrier Plate. 8. Balance Items, If Any.. Instructions For Packing Of Fasteners . 1. Box-1: Item-4 2. Box-2, Item-4, 6 & 7/ Each To Be Packed And Sealed Separately In Trans Parent Polythene Cover Of Minimum 200 Microns With Appropriate Description Label S Kept Inside For Easy Identification. Safety Item Warranty Period: 84 Months After The Date Of Delivery

Location
Tamil Nadu
Due Date
05 Jun, 2024
Amount
Refer Document
Ref. No #31665884 Central Government/Public Sector Live

Supply Of High Tensile Aar H Type Tight Lock Centre Buffer Coupler Head With Transition Screw Coupling, Balance Draft Gear And Its Associated Components For Fitment On Broad Gauge Passenger Coaches Of Indian Railways As Per Rdso.Spe Cn.No. Rdso/2009/Cg-22, Rev -03 One Coupler Set Shall Consists Of The Following - 1. Tig Ht Lock Coupler Head With Transition Screw Coupling And Its Associated Components Qty. 1 No. 2. Balanced Dr Aft Gear With Pivot Pin Qty. 1 No. 3. For Coupler Head With M20 Fasteners Qty. 1 No. 4. Manu Al Uncoupling With M12 Fasteners Qty. 1 No. 5. Rear Carrier Plate For Draft Gear With M16 Fasteners Qt Y. 01 No. 6. Front Carrier Plate For Draft Gear With M16 Fasteners Qty. 1 No. Special Condition:- 1. Maintenance Manual In Soft Copy And Hard Copy Shall Be Supplied With Item. 2. Necessary Test Certificates As Per Rdso .Spec N .No. Rdso/2009/ Cg-22 Rev -01 Shall Be Supplied With Item. 3. Rev.03 Or Latest Revision Of Specification Rds O/2011/Cg-03 Referred In Rdso/2009/Cg-22 Rev -01 Shall Be Followed. 4. Tenderer To Submit Rdso Approved Drawings At The Time Of Quoting The Tender. Safety Item. Warranty Period: 84 Months From The Date Of Supply Or 72 Months From The Date Of Fitment, Whichever Is Earlier As Per Specification No. Rdso/2011/Cg-03 Rev.-3. Ma Ke - Escorts Limited Only Warranty Period: 30 Months After The Date Of Delivery

Location
Uttar Pradesh
Due Date
02 May, 2024
Amount
Refer Document
Ref. No #31609549 Central Government/Public Sector Live

Supply of Srph154036-Mri Conditional Dual Chamber Pacemaker Rate Responsive Ddd R With Appropriate Atrial And Ventricular Bipolar Steroid Eluting Lead Mri Conditi Onal With Life Warranty Provision Of Pacing Therapy For The Use Of The Patients Lif E-Time Including Any No. Of Pulse Generator Replacements As Clinically Required. S Hould Have The Latest Technological Features To Provide Proportionate, Smooth A Nd Appropriate Response Of Pacing Rate To Increased Metabolic Demand, Should Pr Ovide For Atrial And Ventricular Pacing And Sensing With Choice Of At Least 16 Mode S Of Operation, Appropriate Safety Features To Avoid Cross Talk, Optimum Flexibilit Y Of Programming Including Minimal Av Delay Of 30Msec Or Less And Atrial Sensitivit Y Of 0.2Mv Or Less, Detailed Data Storage With Easy Retrieval And Display Of Advanc Ed Diagnostics For Ease Of Clinical Follow Up & Maximal Longevity. Should Be Capabl E Of Programming For Prolonging Longevity And Maximal Cost Effectiveness. Shoul D Be Capable Of Providing Reliable Ventricular Capture With Lowest Battery Drain S O As To Provide Maximum Longevity Of The Pacing System. Preferably As An Automati C Feature Where The Pulse Generator Can Perform A Periodic Threshold Test And R Eliably Verify Ventricular Capture And Adjust Ventricular Pulse Output Parameter S To Minimize Battery Drain Without Compromising Patient Safety. Should Have Feat Ures For Automatic Management Of Arrhythmias Including Pacemaker Mediated Arr Hythmias As Well As Automatic Mode Switching Mode Switch Should Be To And From Ddd To Ddi/Vvir, Provision Of Rate Responsive Pacing After Mode Switch And Automat Ic Reversion To Ddd After Termination Of Mode Switch Triggering Arrhythmias. Sho Uld Have Algorithms To Promote Intrinsic Conduction. Both Atrial And Ventricular Channels Should Have Provision For High Energy Output I.E. Up To At Least 6.0 Volts Pulse Amplitude And Pulse Width Up To Atleast 1.0 Ms, Follow Up Diagnosis And Repro Gramming Should Be Rendered As Effective As Possible Through Provision Of Adequ Ate Information Management Systems On The Programmer. Mri Compatible Leads Sho Uld Be Bipolar, Steroid Eluting And Low Profile Either Tined Or Active Fixation Type 7F Or Smaller Introducer Individually. Leads Should Be From The Same Manufacture R I.E. Manufactured By The Same Company As The Pulse Generator, Not Outsourced A Nd Marketed By Another Company. Pulse Generator And Leads Should Be Suitable Fo R Adult And Paediatric Patients. The Manufacturer / Supplier Should Submit Proof O F Supply To A Major Government Institute. Publications The Safety And E Fficacy Of The Pacemaker And The Leads In Clinical Use Should Be Available In Peer Reviewed Journals. The Latest Programmer With Up Dated Software Should Be Available At All Times Permanently In The Hospital. The Programmer Should Have Fac Ilities For Simultaneous Display Of Multiple Surface Ecg Leads, Intracardiac Electr Ograms, Event Markers, Electronic Calipers And For Recording The Same Both On P Aper And In Electronic Storage Media E.G. Compact Disc Etc., Unit:No

Location
Tamil Nadu
Due Date
03 May, 2024
Amount
Refer Document