Supply Of Surge Protection Devices Spd- Main Incomer, Spd- 625Kva Dg Incomer, Spd125kva Dg Incomer, Spd- Motor Panel, Spd - Lpg Pump 75 Kw, Spd - Lpg Pump 37.5 Kw, Spd - Lpg Pump 22 Kw, Spd - Lpg Compressors 90 Kw, Spd - Air Compressor 75 Kw, Spd - Air Compressor 45 Kw, Spd - Pt 24 V, Spd - Radar Gauges, Spd - Ups 5Kva, Spd - Ups 3.7Kva, Spd - Network Rack Power, Spd - Cctv Network Switch, Spd - Weigh Bridge Load Cell, Spd - Weigh Bridge Input Power, Spd - Plc 24V, Spd - Cp System Incoming Power, Spd - Cp System Dc, Spd - Paging, Epabx, Spd - Servo Gauges, Spd - Hla, Spd - Energy Saver 125Kva, Spd - Earth Mon Sys Main Power, Spd - Cpi Boxes, Spd - Gms Ftu, Spd-Dpt Incomer, Installation And Commissioning
Supply Of High Availability Single Section Digital Axle Counter System Complete With Dual Sensor As Per Rdso Specification No. Rdso/Spn/177/2012 With Version 3.0 Or Latest Warranty Period: 30 Months After The Date Of Delivery High Availablility Single Section Digitial Axle Counterhassdac System Complate With Dual Sens Or As Per Rdso Specition No. Rdso/Spn/177/2012 With Version 3.0 Or Letest Warranty Period: 30 Months Aft Er The Date Of Delivery Supply Installation Testing Wiring & Commissioning Of High Availability Single Section Digital Axle Co Unter Hassdac System Complete With Dual Detection As Per Rdso Specification No Rdso/Spn 177/2012 V Ersion 3. 0 Or Latest Consisting Of Itrack Side High Availability Digital Axle Counter Unit Dacf-720P 2Nos Iih Igh Frequency Tx Coil & Rx Coilad-711 Each Set Consisting Of Web Mounting Type 2 Nos Tx And 2 Nos Rx C Oil 02 Sets Iii Vital Relay Box Model Vr-722 02 Nos Duly Wired With The Following Relays Avital Relays Qn1 K 24 V 6F- 6B 02Nos B Reset Relay Qn1 K 24 V 6F-6B 1 No C Pr Relay Onn1 24 V 6F-2B Dual 1 No Iv Clamp With Deflector Plates And Hardware 4 Nos V Reset Box Model No259a 02 Nos Vi Surge Voltage Protection Device Mounted On Din Rail 02 Nos Mtallation Requires Following Attention A The Axle Counter Will B E High Availability Single Section Type Wih Two Detection Points And It Is Possible To Install It Without Trolly Protection Track Circuit The Axle Counter Must Consist Of Following The Wire And Other Winng Material Will Be Arranged By Cont Ractor At Site B Mounting Of High Frequency Tx And Rx Coil - 2 Sets Each Set Consist Of Web Mounting Type 2 No Of Tx And 2 No Of Rx C Mounting Of Track Side Digital Axle Counter Unit-2 Nos D Fixing Of Vital Relays Etc Duly Wire D-2 Nos E Clamping With Deflector Plate And Hard Ware For Mounting Of Two Set Of Tx & Rx Coil. F Resetting Arra Ngement For Each Axle Counter Gall The Wiring Material Required For Installation And Commissioning Shall Be Arran Ged By Contractor Hthis Also Includes Integration With Existing Sge/ Tokenless/Token Block Instruments Were Re Quired As Per Instructions Of Site Engineer. All Tx/Rx Coils Shall Each Be Of 15 Meter Length. Inspection- Rdso Fo R Supply Portion Warranty Period: 30 Months After The Date Of Delivery Supply Installation, Testing, Wiring & Commissioning Of High Availability Single Section Digital Axle Co Unter Hassdac System Complete With Dual Detection As Per Rdso Specification No.Rdso/Spn/177/2012 V Ersion 3.0Or Lastest Consisting Of. Itrack Side High Availability Digital Axle Counter Unit Dacf-720P 2Nos.Iihi Gh Frequency Tx Coil &Rx Coilad-711 Each Set Consisting Of Web Mounting Type 2 Nos Tx And 2 Nos Rx Co Il 02 Sets.Iiivital Relay Box Model Vr-722 02 Nos Duly Wired With The Following Relays. Avital Relays Qn 1K. 24 V 6F-6B 02Nos B Reset Relay Qn 1K 24 V 6F-6B 1 No. C Pr Relay Qnn1 24 V 6F-2B Dual 1No. Iv Clamp With Deflector Plates And Hardware 4 Nos. V Reset Box Model No259a 02 Nos. Vi Surge Voltage Prote Ction Device Mounted On Din Rail 02 Nos.Installation Requires Following Attention. A.The Axle Counter Will Be Hig H Availability Single Section Type Wih Two Detection Points And It Is Possible To Install It Without Trolly Protection Track Circuit The Axle Counter Must Consist Of Following.The Wire And Other Wiring Material Will Be Arranged By Contractor At Site. B Mounting Of High Frequency Tx And Rx Coil-2 Sets, Each Set Consist Of Web Mounting Type 2 No.Of Tx A Nd 2 No Of Rx. . C Mounting Of Track Side Digital Axle Counter Unit-2 Nos.D Fixing Of Vital Relays Etc.Duly Wired-2 Nos. E Clamping With Deflector Plate And Hard Ware For Mounting Of Two Set Of Tx & Rx Coil. F Resetting Arrange Ment For Each Axle Counter Gall The Wiring Material Required For Installation And Commissioning Shall Be Arranged By Contractor. Hthis Also Includes Integration With Existing Sge/ Tokenless/Token Block Instruments Were Requir Ed As Per Instructions Of Site Engineer. All Tx/Rx Coils Shall Each Be Of 15 Meter Length. Warranty Period: 30 Months After The Date Of Delivery Supply Of High Availability Single Section Digital Axle Counter Hassdac Using Dual Track Sensor Device As Per Rdso Specn. No. Rdso/Spn/177/2012 Version 3 Para 3.04 Of Chapter Iii Atrack Side High Availability Single Section Digital Axle Counter Unit 2 Nos. Bhigh Frequency Tx Coil And Rx Coil Each Set Consi St Of Web Mounting Type Tx Coils 2 Nos., Rx Coils -2 Nos., 2 Sets. Cvr /Pr Box Duly Wired For Following 2 N Os. Ivital Relays Qn1k, 24V, 6F/6B 2 Nos. Ii Pr Relays Qnn1, 24V, 6F/2B 02 Nos. Dclamps With Defle Ctor Plates And Hardware Etc. 4 Nos. Esurge Voltage Protection Device And Filter Card To Be Mounted On Din Rail 2 Nos. Freset Boxes And All Other Accessories Required For Installation And Commissioning Of High Availability Single Section Digital Axle Counter Will Be Supplied By The Contractor. Warranty Period: 30 Months After The Dat E Of Delivery Supply Of High Availability Single Section Digital Axle Counter Hassdac Using Dual Track Sensor Device As Per Rdso Specn. No. Rdso/Spn/177/2012 Version 3 Para 3.04 Of Chapter Iii Atrack Side High Availability Single Section Digital Axle Counter Unit 2 Nos. Bhigh Frequency Tx Coil And Rx Coil Each Set Consi St Of Web Mounting Type Tx Coils 2 Nos., Rx Coils -2 Nos., 2 Sets. Cvr /Pr Box Duly Wired For Following 2 N Os. Ivital Relays Qn1k, 24V, 6F/6B 2 Nos. Ii Pr Relays Qnn1, 24V, 6F/2B 02 Nos. Dclamps With Defle Ctor Plates And Hardware Etc. 4 Nos. Esurge Voltage Protection Device And Filter Card To Be Mounted On Din Rail 2 Nos. Freset Boxes And All Other Accessories Required For Installation And Commissioning Of High Availability Single Section Digital Axle Counter Will Be Supplied By The Contractor. Warranty Period: 30 Months After The Dat E Of Delivery High Availability Single Section Digital Axle Counters Hassdac With Dual Sensor System As Per Rdso/Spn/177/2012 Version 3 Or Latest. This Includes The Supply Of High Frequency Web Mounting Type Tx Coil/ Rx Coil, Vr/Pr Box Duly Wired, Vital Relays, Pr Relays, Clamp With Deflector Plates & Hardware. Dual Display Re Set Box With Auto Resetting Facility, Surge Voltage Protection Devices And Filter Card To Be Mounted On Din Rail Etc A S Per Oem For Complete Intallation & Testing & Commissioning Of Hassdac System Note; One Set Of Hassd Ac System Will Include Equipment Required To Monitor One Up Line Or One Dn Line Of A Full Block Section Between Two Stations. Inspection Rdso Warranty Period: 30 Months After The Date Of Delivery Supply, Installation And Commissioning Of High Availability Single Section Digital Axle Counter Syste M Hassdac Complete With Dual Sensor As Per Rdso Spec. No. Rdso/Spn/177/2012 With Ver 3.0 Or Letest C Onsisting Of Track Side High Availability Digital Axle Counter Unit Dacf-720P-02 No 2019 High Frequency Tx Coil An D Rx Coil Ad-71Dc Each Set Consisting Of Web Monitoring Type 2No. Tx Coil And 2No. Rx Coil 02Set Vital Relay B Ase Model Vr -722-2Nos. Duly Wired With Following Relays A Vital Relays Qn 1K24v 6F/6B 2Nos. B Reset Relay S Qn1k 24V 6F/6B 1Nos. C Pr Relay Qn 1 K24v 6F/6B Dual 1Nos. D Clamp With Deflector Plate Hardware 4 Nos. All Fitting Wiring Arrangement Is To Be Done By Firm Warranty Period: 30 Months After The Date Of Delivery High Avaliability Single Section Digital Axle Counter System Complete With Dual Sensor As Per Rd So Specification No. Rdso/Spn/177/2012 With Version 3.0Or Latest Consisting Of Track Side High Availibility Digit Al Axle Counter Unit Dacf-720P-02 No.High Frequency Tx Coil And Rx Coil Ad-71Dc Each Set Consisting Of Web Monitoring Type 2No.Tx Coil And2no. Rx Coil 02 Set Vital Relay Base Model Vr-722Vr 722 -2No. Duly Wired With Foll Owing Relays Avital Relay Qn1k 24V6f/6B 2No. B Reset Relay Qn1k24v 6F/6B 1No.Cpr Relay Qn1k, 24V 6F/2B 1No.Clamp With Deflector Plate And Hardware 4No. Warranty Period: 30 Months After The Date Of Deliver Y
Supply Of Dig Micro Cont Aanun, Acont Mini Tca2 M22, Conv Dc Dc Ip 40 To 60V Op 24V 2.5A Access, Transducer Dc Dc Ip0 75Mv Op4 20Ma Aux 24 To 60V Dc Tv808 E8 Housing, Transducer Dc Dc Ip 0 To 100V Op 4-20Ma Aux 24 To 60V Dc Tv808 E8 Housing, Battery Reverse Polarity Relay Module Pcb Nos 302R1 Ce, 24V To 12V 1.5A Dcdc Converter, Dc U And O Voltage Relay Card As Module Pcb Nos 44Ra7 Ce, Cns2afuse Link415vstagtaghrccns, 500Mafuse Link230vsmallglassot, Wire Wound Si Coted 500E Radial 25W Ot, Wire Wound Si Coted 500E Radial 50W Ot, Surge Protection Device Val Ms320 1 Plus 1 1Ph Phonix, Dd Module Ndd46n160 46A 1600Piv Or Equivalent, Dig Micro Cont Aanun Module, Electro Capscrew 63Mm 5000Mfd 200Vdc Pg6di Alcon, Pcont T Range Tc1 D2510 U5 25A3pac 1No 240V Accns, Acont Mini Tca3 M22 Fd 10A 2No Plus 2Nc 110V Dc C And S, Acont Mini Tca2 M22 M 10A 2No Plus 2Nc 220V Ac Cns, Add-On-Block Ta1 M22 2No Plus 2Nc For Mini Acont C And S, Ac Voltage Protection Relay Under And Over Vpr 126 2R Multispan, Conv Dc Dc Ip90- 270Vac, Transducer Dc Dc Ip0 75Mv Op4 20Ma, Transducer Dcdc, 3Ph Fcbc Scr Digital Controller Module Cmu103t Ce, Dc U And O Voltage Relay Card As Module Pcb Nos 44Ra7 Ce, Earth Leakage Relay Card As Module Pcb Nos 34R4 Ce, Ffd 6Fs W Relay Module 2In1 Pcb Nos 47Ar4 2 Ce, Etc
Supply, Installation, Testing & Commissioning Of 55 Nos Spds Surge Protection Devices For Lightning Protection System Of Dbpl Telecom System
Supply, Installation, Testing And Commissioning Of Smps Based Integrated Power Supply Ips Sys Tem As Per Rdso Spec. No.Rdso/Spn/165/2012 Ver.-3.0 Along With Surge Protection Device, Status Monitorin G Panel, Spares, Tool Kit, Lmla Battery Consisting Of 55 Plus 5 Cells Cells As Per Rdso Spec. Irs:S-88/2004 Alo Ng With Battery Stand.The Configuration Of Ips Should Be As Per Ncr/Hq Drawing No. Typ/2017 /0002-10 For Ibs With Lc Gate .This Includes Transporation To Consignee Depot, From Consignee Depot To Site. Warranty Period: 3 0 Months After The Date Of Delivery Supply, Installation, Testing And Commissoning Of Smps Based Integrated Power Supply Ipssys Tem As Per Rdso Spec. No. Rdso/Spn/165/2012 Ver 3.0 Aiong With Surge Protection Device, Status Monitoring Panel, Spares, Tool Kit, Lmla Battery Consisting Of 55 Plus 5 Sells Cellsas Per Rdso Spece.Irs:S-88/2004 Along With Battery Stand . The Configuration Of Ips Should Be Per Ncr/Hq Drawing No. Typ/2017/0002-11 For Relay Hu T /Lsc With Aftc, Axle Counter And Lc Gate.This Includes Transportation To Consignee Depot, From Consignee Dep Ot To Site, Installation And Commissioning Of Integrated Power Supply System After Duly Filling Precommissioning C Heck List Jointly By Rdso Approved Vendor And Railway Representative.Item Shall Be Procured Though Store Wi Th Gst, Frieght And Commissioning Charges.This Includes Transporation To Consignee Depot, From C Onsignee Depot To Site. Warranty Period: 30 Months After The Date Of Delivery Supply And Comissioning Of Smps Based Integrated Power Supply System For Interlocked Lc Gate In Re Section As Per Rdso Specn.No. Rdso/Spn/165/2023 Ver. 4. 0 Amdt.1 As Per Drawing Attached Of Along With Battery Set Of 110V/300Ah.This Includes Tr Ansporation To Consignee Depot, From Consignee Depot To Site. Warranty Period: 30 Months After The Date Of Del Ivery Supply Installation Testing And Commissioning Of Smps Based Integrated Power Supply Ips Syst Em, As Per Rdso Spec. No. Rdso/Spn/165/2012 Ver.3.0 Along With Surge Protection Device, Status Monitorin G Panel, Spares, Tool Kit, Lmla Battery Consisting Of 55 Plus 5 Cells Cells As Per Rdso Spec. Irs:S-88/2004 A Long With Battery Stand. The Configuration Of Ips Should Be As Per Ncr/ Hq Drawing No. Typ/2017/0002-06 For Ei Station Up To 04 Lines With Block Panel And Lc Gate. This Includes Transportation To Consignee Depot From Consi Gnee Depot To Site, Installation And Commissioning Of Integrated Power Supply System After Duly Filing Pre Commi Ssioning Check List Jointly By Rdso Approved Vendor And Railway Representative.This Includes Transporation To C Onsignee Depot, From Consignee Depot To Site. Warranty Period: 30 Months After The Date Of Delivery Supply, Installation Testing And Commissioning Of Smps Based Integrated Power Supply System I Ps , As Per Rdso Spec. No. Rdso/Spn/165/2012 Ver.3.0 Along With Surge Protection Device, Status Monitori Ng Panel, Spares, Tool Kit, Lmla Battery Consisting Of 55 Plus 5 Cells Cell As Per Rdso Spec. Irs-S-88/2004 Al Ong With Battery Stand. The Configuration Of Ips Should Be As Per Ncr/Hq Drawing No. Typ/2017/0002-08 For Ei Station Up To 6 Lines With Block Panel And Lc Gate.This Include Transporation To Consignee Depot To Site, Installatio N And Commissioning Of Integrated Power Supply System After Duly Filling Pre Commissioning Checklist Jointly By Rdso Approved Vendor And Railway Representative.This Includes Transporation To Consignee Depot, From Consig Nee Depot To Site. Warranty Period: 30 Months After The Date Of Delivery