Time Management System Tenders

(Select any tender from the list to send an email)
Ref. No #31609549 Central Government/Public Sector Live

Supply of Srph154036-Mri Conditional Dual Chamber Pacemaker Rate Responsive Ddd R With Appropriate Atrial And Ventricular Bipolar Steroid Eluting Lead Mri Conditi Onal With Life Warranty Provision Of Pacing Therapy For The Use Of The Patients Lif E- Including Any No. Of Pulse Generator Replacements As Clinically Required. S Hould Have The Latest Technological Features To Provide Proportionate, Smooth A Nd Appropriate Response Of Pacing Rate To Increased Metabolic Demand, Should Pr Ovide For Atrial And Ventricular Pacing And Sensing With Choice Of At Least 16 Mode S Of Operation, Appropriate Safety Features To Avoid Cross Talk, Optimum Flexibilit Y Of Programming Including Minimal Av Delay Of 30Msec Or Less And Atrial Sensitivit Y Of 0.2Mv Or Less, Detailed Data Storage With Easy Retrieval And Display Of Advanc Ed Diagnostics For Ease Of Clinical Follow Up & Maximal Longevity. Should Be Capabl E Of Programming For Prolonging Longevity And Maximal Cost Effectiveness. Shoul D Be Capable Of Providing Reliable Ventricular Capture With Lowest Battery Drain S O As To Provide Maximum Longevity Of The Pacing . Preferably As An Automati C Feature Where The Pulse Generator Can Perform A Periodic Threshold Test And R Eliably Verify Ventricular Capture And Adjust Ventricular Pulse Output Parameter S To Minimize Battery Drain Without Compromising Patient Safety. Should Have Feat Ures For Automatic Of Arrhythmias Including Pacemaker Mediated Arr Hythmias As Well As Automatic Mode Switching Mode Switch Should Be To And From Ddd To Ddi/Vvir, Provision Of Rate Responsive Pacing After Mode Switch And Automat Ic Reversion To Ddd After Termination Of Mode Switch Triggering Arrhythmias. Sho Uld Have Algorithms To Promote Intrinsic Conduction. Both Atrial And Ventricular Channels Should Have Provision For High Energy Output I.E. Up To At Least 6.0 Volts Pulse Amplitude And Pulse Width Up To Atleast 1.0 Ms, Follow Up Diagnosis And Repro Gramming Should Be Rendered As Effective As Possible Through Provision Of Adequ Ate Information s On The Programmer. Mri Compatible Leads Sho Uld Be Bipolar, Steroid Eluting And Low Profile Either Tined Or Active Fixation Type 7F Or Smaller Introducer Individually. Leads Should Be From The Same Manufacture R I.E. Manufactured By The Same Company As The Pulse Generator, Not Outsourced A Nd Marketed By Another Company. Pulse Generator And Leads Should Be Suitable Fo R Adult And Paediatric Patients. The Manufacturer / Supplier Should Submit Proof O F Supply To A Major Government Institute. Publications Supporting The Safety And E Fficacy Of The Pacemaker Device And The Leads In Clinical Use Should Be Available In Peer Reviewed Journals. The Latest Programmer With Up Dated Software Should Be Available At All s Permanently In The Hospital. The Programmer Should Have Fac Ilities For Simultaneous Display Of Multiple Surface Ecg Leads, Intracardiac Electr Ograms, Event Markers, Electronic Calipers And For Recording The Same Both On P Aper And In Electronic Storage Media E.G. Compact Disc Etc., Unit:No

Location
Tamil Nadu
Due Date
03 May, 2024
Amount
Refer Document
Ref. No #31584976 Central Government/Public Sector Live

Supply of Mri Conditional Dual Chamber Implantable Cardioverter Defibrillator With Df - 4 Connector And Option Of Dual Shocking Coil.. Sr Ph 154066-Mri Conditional Dual Chamber Implantable Cardioverter Defibri Llator With Appropriate Atrial And Ventricular Pace / Sense Leads With Df - 4 C Onnector And Option Of Dual Shocking Coil Leads And Accessories. Should Hav E Advanced Features For The Reliable Detection And Of Ventricular Tach Ycardia And Ventricular Fibrillation, Including Features To Differentiate Supra-Ventr Icular Tachycardia From Ventricular Tachycardia And Features To Avoid Inappropriat E Shocks, Tiered Therapy Delivery, Choice Of Atp Protocols And Shock Energies, And S Hould Be Capable Of Delivering Maximum Energy Of 35J Or More And Should Have Featu Res For Of High Defibrillation Energy Requirement. Charge s Should Be Within Clinically Acceptable Limits Throughout The Life Of The Device.Leads Sho Uld Be Low Profile And Choice Of Both Active Or Passive Fixation Leads Should Be Avail Able. Should Have Features For Automatically Alerting The Patient In The Event Of A Ba Ttery Or Lead Fault. Data Storage, Retrieval And Display Should Be Efficient And User Friendly. Data Storage Should Include Episode Details, Therapy Delivered And Results And Electrogram Storage And Should Be Comprehensive. Bradycardia Pacing Includi Ng Independently Programmable Parameters For High Output For Post-Shock Pacing Should Be Available. Warranty Terms Should Be Specified Clearly Along With The Quot Ation. Firms Should Submit Detailed Literature Of The Item In A Bulletin/Tutorial Forma T Which Should Contain All The Details About The Product. Compliance Statement Of E Ach Specification To Be Submitted. The Firm Quoting The Tender Should Submit A Letter Of Authorisation From The Principal Firm/Original Equipment Manufacturer. The Manuf Acturer / Supplier Should Submit Proof Of Supply To A Major Government Institute. Th E Safety And Efficacy Of The Icd Device And The Lead In Clinical Use Should Be Documen Ted In Scientific Publications. All The Above Mentioned Specifications Are Essential An D Mandatory And Should Be Submitted At The Of Initial Tender Submission. Unit:No

Location
Tamil Nadu
Due Date
02 May, 2024
Amount
Refer Document
Ref. No #31584993 Central Government/Public Sector Live

Supply of Mri Conditional Dual Chamber Implantable Cardioverter Defibrillator . Srph154064-Mri Conditional Dual Chamber Implantable Cardioverter Defibril Lator With Appropriate Atrial And Ventricular Pace / Sense Leads And Option O F Dual Shocking Coil Leads And Accessories. Should Have Advanced Features F Or The Reliable Detection And Of Ventricular Tachycardia And Ventricul Ar Fibrillation, Including Features To Differentiate Supra-Ventricular Tachycardia Fr Om Ventricular Tachycardia And Features To Avoid Inappropriate Shocks, Tiered Ther Apy Delivery, Choice Of Atp Protocols And Shock Energies, And Should Be Capable Of D Elivering Maximum Energy Of 35J Or More And Should Have Features For O F High Defibrillation Energy Requirement. Charge s Should Be Within Clinically Ac Ceptable Limits Throughout The Life Of The Device. Leads Should Be Low Profile An D Choice Of Both Active Or Passive Fixation Leads Should Be Available. Should Have Fea Tures For Automatically Alerting The Patient In The Event Of A Battery Or Lead Fault. Data Storage, Retrieval And Display Should Be Efficient And User Friendly. Data Stora Ge Should Include Episode Details, Therapy Delivered And Results And Electrogram St Orage And Should Be Comprehensive. Bradycardia Pacing Including Independently Pr Ogrammable Parameters For High Output For Post-Shock Pacing Should Be Available. Warranty Terms Should Be Specified Clearly Along With The Quotation. Firms Should S Ubmit Detailed Literature Of The Item In A Bulletin/Tutorial Format Which Should Conta In All The Details About The Product. Compliance Statement Of Each Specification To B E Submitted. The Firm Quoting The Tender Should Submit A Letter Of Authorisation Fro M The Principal Firm/Original Equipment Manufacturer. The Manufacturer / Supplier Sh Ould Submit Proof Of Supply To A Major Government Institute. The Safety And Efficac Y Of The Icd Device And The Lead In Clinical Use Should Be Documented In Scientific Publ Ications. All The Above Mentioned Specifications Are Essential And Mandatory And Sho Uld Be Submitted At The Of Initial Tender Submission. Unit: No

Location
Tamil Nadu
Due Date
03 May, 2024
Amount
Refer Document
Ref. No #31582726 State Government Live   GeM Tender

Supply Of Library Books Hydraulic Machines, Fluid Mechanics For Engineers, A Handbook Of Fire Workmanship, Principles Of Heat Transfer, Fundamental Of Heat And Mass Transfer 4Th Ed., Introduction To Operational Amplifier Theory And Applications, The Art Of Electronics 2Nd Ed., Electronic Devices 9Th Ed., Digital Logic And Computer Design, Fundamentals Of Digital Circuits, Modern Digital Electronics 3Rd Ed., Digital Electronics An Introduction To Theory And Practice, Modern Digital Electronics 4Th Ed., Power Electronics Circuits, Devices And Applications, Power Electronics Converters, Applications And Design, Fundamentals Of Power Electronics, Power Electronics Essentials And Applications, Wireless And Personal Communication s, Principles Of Mobile Communications 2Nd Ed., Introduction To Space Wireless Communications, Space Wireless Communication s, Satellite Communications 2Nd Ed., Satellite Communications s s, Techniques And Technology 5Th Ed., Principles Of Fire Safety Standards For Building Construction, Fire Stopping Book, Enclosure Fire Dynamics, Fundamentals Of Fire Phenomena, An Introduction To Combustion, Automobile Engineering, Automotive Mechanics, Motor Vehicle Technology, Fundamentals Of Industrial Instrumentation And Process Control, Industrial Instrumentation And Control 3Rd Ed., Process Dynamics And Control 2Nd Ed, Chemical Process Control An Introduction To Theory And Practice, Control s Principles And Design, Automatic Control , Control s Engineering, Design Of Feedback Control s, Linear Control Analysis And Design Conventional And Modern, Instrumentation And Control s, Mechanical Measurements 6Th Ed., Process, Industrial Instruments And Controls Handbook 5Th Ed., Electronic Instrumentation And Measurements 2Nd Ed. Electronic Instrumentation And Measurements 2Nd Ed., , Essentials Of , Industrial Engineering And , Engineering Industrial Engineering And , 6Th Ed., Information s 8Th Ed., Operations Research, Hamilton, Boyal And Messmani Human Embryology, Morris Human Anatomy, Bainddbridge And Mainsions Principles Of Physiology, Essentials Of Human Physiology, Mcdowell Halliburtons Handbook Of Physiology And Biochemistry, Parson Biochemistry In Relation To Human Physiology, Burns Introduction To Biophysics, Findlay Physical Chemistry For Students Of Medicine, Wintrobe Haematology, Ghosh Materia Medica, Burn Practical Pharmacology, A First Course In The Finite Element Method, The Finite Element Method Its Basis And Fundamentals, Introduction To Mathematical Fire Modeling, Sfpe Guide To Human Behavior In Fire, Fire Dynamics Simulator Technical Reference Guide, Industrial Safety 3Rd Ed., Industrial Safety, Industrial Fire Protection Handbook, Nfpa 557 Standard For Determination Of Fire Load For Use In Structural Fire Protection Design, Fire Safety 3Rd Ed., Occupational Health And Safety , Industrial Safety , Fire And Arson Investigation, Arson Investigation, Hazard Analysis Techniques For , An Introduction To Reliability And Maintainability Engineering, Probabilistic Risk Assessment And For Engineers And Scientists 2Nd Ed., Quantitative Risk Assessment In Fire Safety, Fire Protection Detection, Notification And Suppression 2Nd Ed., Nuclear Reactor Engineering Principles And Concepts, Elements Of Nuclear Safety, Nuclear Power Reactor Safety, Nuclear Safety, Nptelweb Course On Nuclear Reactor Technology, Principles Of Occupational Health And Hygiene An Introduction 2Nd Ed., Hunters Diseases Of Occupation 7Th Ed., Human Factors In Engineering And Design 7Th Ed., Industrial And Occupational Health, Handbook Of Occupational Health And Safety, Safety, Health And Environment Hand Book, International Occupational Hygiene Association Ioha, Vulnerability In Disaster Discourse, Disaster A Disaster Managers Handbook, Environmental Knowledge For Disaster Risk , Disasters In India Studies Of Grim Reality, Disaster , Introduction To Robotics 2Nd Ed., Robotics, Robotics And Control, Robotics And Automation, Introduction To Robotics Mechanics And Control, Computer Security Principles And Practices 6Th Ed., Cyber Security Understanding Cyber Crimes, Computer Forensics And Legal Perspectives, Applied Cryptography Protocols, Algorithms And Source Code In C, Algorithms 2Nd Ed., Cryptography And Security, Cryptography And Network Security 2Nd Ed., Information Security Principles And Practices, Internet Of Things, A Hands On Approach, Introduction To Internet Of Things A Practical Approach, The Internet Of Things Enabling Technologies, Platforms And Use Cases, Internet Of Things, Designing The Internet Of Things, Internet Of Things Architecture And Design, A Classical Approach To Artificial Intelligence, Artificial Intelligence, Artificial Intelligence A Modern Approach 3Rd Ed.

Location
Maharashtra
Due Date
22 Apr, 2024
Amount
Refer Document