Electrical Testing And Supplies - Tan-Delta Testing Of Transformer Reacto, Lt Acb Breaker Test Servicing, Ht Vcb Breaker Testing Servicing, Buchholz Relay Test, Thermal Omicron B2hv Relay Test, Partial Discharge Test Of Transformer, Third Harmonic Testing Of La Lightning, Insulation Mat Test, Testing Of Mccb Rccb, Insulation Resistance Test Of Motors, Pi Polarization Index Test Of Motors, Transformer Oil Test As Per Is 1866, Voltameter Ammeter Calibration, Calibration Of Energy Meters, Vcb Bottles Inspection Test For Healthi, Vlf Very Low Frequency Testing Of 100, Thermography Of Panels, Vfd U.P.S Inver, Electromechanical Relays Testing, Numerical Relays Testing, Transformer Oil Filtration, Electrical Safety Audit Esa For, Pi Of 100 Power Cables, Ir Of 100 Power Cables, Current Transformer Testing, Wti Winding Temperature Indicator Cali, Oti Oil Temperature Indicator Calibrat, Liasoning Charges-Cea, Supply Of Megger Tester, Led 300 Watts For High Mast Tower, Led Lights 90 W, Earthpit Testing, Lt Hand Gloves, Ht Hand Gloves, Sply Flp Switches, 4C 1.5Sqmm Armored Cable, Vcb Battery, Capacitor 25Kvar, Capacitor 20 Kvar, Capacitor 10 Kvar, Ampere Meters For Panels, Hammer Driill Machine, Earthstrips 50 6, Earthstrips 25 6, 4 Sqmm Earthing Cable, Earth Tester
Supply, Installation, Testing, Commissioning Of Earthing System For Ats Complex And Iatc Tower At Navi Mumbai Airport, Supply Of Copper Plate, Supply Of Pvc Pipe For Watering, Supply Of Salt, Supply Of Charcoal, Supply Of Hdpe Pipes, Supply Of Copper Strips, Supply Of Multi Strand Single Core Pvc Insulated Copper Cable, Supply And Installation Of Sub Equipotential Earth Bus Bar, Supply And Installation Of Main Equipotential Earth Bus Bar, Installation Job For Earth Pit Including Inspection Chamber, Installation And Laying Of Copper Strip For Earth Grid, Installation And Laying Of Copper Strip From Earth Grid To Building, Installation And Laying Of Copper Strip From Ups Panel Room At Ground Floor To All The Rooms In All The Floors Of The Building And Also To The Roof Area Of The Building
Supply Of Material -P.P Reel Insulator -Must Be Of Virgin Plastic Material. Polypropylene Or Equivalent With Break Down Voltage Of 15 Kv, Strain Insulator-Must Of Poly Polypropylene Plastic Rated For 15Kv Uv Stabilized, Corner Post Gi- 8 Ft., Gi-2, 14 Guage Thickness, Painted Having Diametrically Opposite Holes Of Size 6 Mm At Required Interval Of Fencing Installation, Intermediate Post T Angle Post 8 Feet Painted 25Mmx25mmx3mm Having Holes Of Size 6 Mm At Required Intervels Of Fencing Instllation, Supporting Post 6 Feet Gi 1 Inch 14 Guage Thickness Painted, Stay T Angle 2 Feet Painted 25 Mmx25mm X 3Mm, 12 Swg Ht Wire 12 Guage 2.5 Mm Dia High Tensile Wire With Sink Coating For Use As Conducting Wire Winding Strain Insulator, 14 Swg Binding Wire-High Quality Zinc Coating Wire For Binding Reel Insulators, Tighing Support Post With Corner Post, Wire Tightner-Permanant Wire Tighter Made Of Special Aluminium Alloy Designed For Kv, Uv Stabilized, Joint Clamp With Nut And Bolt- Supply Of Joint Clamp With Nuts And Bolt Gi Galavanized Coating For Fastening Conducting Wire Around Posts, Hot Dipped Galvanised , Earth Rod-Copper Plated Earth Rod 14 Mm -3 Ft. Length, Earthing Compound 8 Kg, Tension Spring Spring Steel Cable Of Making Compresion Loads, Galvanised 15Cm Length, Withstand 400Kg , Gate Handle-Steel Rope With Handle And Spring Assembly. Handle Made Of Polyethylene, Lead Out Cable For Fence System Double Insulated Gi Cable Inner Core Wire 2 Sq.Mm. Hot Dipped Galvanised Steel Core, Capable Of With, Standing 15Kv Should Be Provided To Prevent Bimetal Salt Formation At Connections, Single Core 2.5 Mm Sq. Cable-2.5 Mm² Single Core Copper Cable For Connecting The Solar Panel To The Tubular Battery Through Charge Control Unit With Required Terminal Sockets, Nut And Bolt, Washer, Lightining Diverter -15Kv-50Kv Rod Gap Arrester, Must Be Capable Of Diverting Stray Lightning And Adjustable For Spark Gaps Adequate Earthing To Be Provided, 100 Watt Solar Panel- 100 Watt/ 12 Volt And Above Poly Crystalline With 10 Year Warranty Having Iec/Mnre Certification, Charge Control Unit-20 A 12/24 V Pwm Charge Controller Unit Of Standard Make Suitable To Control The Charging Of The Tubular Battery Energizer With 10 Kv Output Safety Standards To Be Followed Are Bis 302-2-76 Iec60335-2-76. Switch-High, Medium And Low Power Setting. Fence Alarm System Covering Area Of 1.5 Km, Solar Panel Supporting Stand With Metal Box Painted For Battery And Energiser - 18 Guage Thickness Metal Boxlockable - Painted. Gi-Sheet, Painted Should Be Capable Of Housing Batterry, Charge Controller And Energizer And Fixed With Required Clamps And Nut And Bolt On Solar Panel Support Stand Made Of Gi Pipe Of 50Mm Diameter And B Class Type With Suitable Arrangement For Holding The Panel Warning Sign-Polyethylene Plastic With Satuatory Warning With Sign, Tubular Battery 12 V, 100Ah- 12 V, 100 Ah C10 Rating With Full 5 Year Replacement Warranty Tower Battery For Energising The Energiser, Digital Volt Meter- Must Display Fence Voltage Digitally Upto 15Kv . Made Of Non Shocking Plastic, Tool Kit Consisting Of Wire Tighterner Rod, Double Headed Spanner, High Tensile Wire Cutter And Cutting Plier For Installation Of New 5 Line Solar Power Fence
Electrical Work In C/W Repair, Improvement Of Earthing And Servicing Of High Mast Tower Over