Wooden Cart Tenders

(Select any tender from the list to send an email)
Ref. No #34439841 Central Government/Public Sector Live   GeM Tender

Gem Bids For 4 Industrial Cooling Fan Man Coolers As Per Is 6272 Q3

Location
Telangana
Due Date
17 May, 2025
Amount
Refer Document
Ref. No #34424171 Central Government/Public Sector Live   GeM Tender

Gem Bids For 4 Oil Cooler And After Coolar Without Fan & Fan Motor Part No 2740148550274001950

Location
Jharkhand
Due Date
15 May, 2025
Amount
Refer Document
Ref. No #34422539 State Government Live

Supply Of Tent Cooler/fan File

Location
Madhya Pradesh
Due Date
02 May, 2025
Amount
88.8 Thousand
Ref. No #34420849 Central Government/Public Sector Live   GeM Tender

Gem bids for 8 Industrial Cooling Fan Man Coolers As Per Is 6272 Q3

Location
Kerala
Due Date
05 May, 2025
Amount
Refer Document
Ref. No #34419807 Central Government/Public Sector Live   GeM Tender

Gem Bids For Manpower , Cmc Of Dandelion Globe Type Fountain , Servicing Of Ceiling Fans , Painting Of Db, Out Door Panel, Feeder Pillar , Painting Of Post Top Poles Up To 4 Mtr , Painting Of Street Light Pole 6 To 9 Mtr , Labour Charges For Lowering And Lifting Of Submersible Pump Set , Repairing Of Ceiling Fans , Repairing Of 12 Inch Exhaust Fan , Repairing Of Heavy Duty Exhaust Fan , Repairing Of Wall Fan , Providing And Replacement Of Damage Or Rusted 1.5 Inch Dia Gi B Class Pipeline , Providing And Replacement Of Damage Or Rusted 2 Inch Dia Gi B Class Pipeline , Providing And Replacement Of Damage Or Rusted 3 Inch Dia Gi B Class Pipeline , Providing And Fixing Wood Wool Pads For Desert Cooler , Rewinding Of Ceiling Fan Motors , Rewinding Of Desert Cooler Fan Motors , Rewinding Of Exhaust Fan Motors Up To 300 Mm , Rewinding Of Heavy Duty Exhaust Fan , Rewinding Of Wall Fan Motors , Rewinding Of 3phase Monoset Openwell Pump Motor 12 To 15 Hp , Rewinding Of 3phase Monoset Openwell Pump Motor 7.5 Hp , Rewinding Of 3phase Monoblock Or Booster Pump Set 7.5 Hp , Rewinding Of 3phase 8 To 10 Hp Submersible Pump Set , Rewinding Of 3phase 5 To 6 Hp Submersible Pump Set , Repairing Of 3phase Monoset Openwell Pump 12 To 15 Hp , Repairing Of 3phase Monoset Openwell Pump Motor 7.5 Hp , Repairing Of 3phase Monoblock Or Booster Pump Motor 7.5 Hp , Repairing Of 3phase 8 To 10 Hp Submersible Pump Set , Repairing Of 3phase 5 To 6 Hp Submersible Pump Set , Detection Of Lt Cable Fault By Using Lt Cable Fault Locator Machine , Supply Of 7 To 9-watt Led Bulb , Supply Of 36-watt Electronic Ballast , Supply Of 36-40 Watt Ftl Starter , Supply Of 36-watt Fluorescent Tube Light , Supply Of 20w T8 4 Feet Led Tube Light Rod

Location
Delhi
Due Date
14 May, 2025
Amount
Refer Document
Ref. No #34404950 Central Government/Public Sector Live   GeM Tender

Gem Bids For "comprehensive Maintenance Contract Of All Vrv/ Vrf System Including All Idu & Odu Of All Capacity, Ahus & Tfas, Referigerant Copper Pipe, Drain Pipe, Inline Fan, Duct/pvc Pipe With Lt Panel For Odu & Idu Including All Installation As Mentioned In Appendix I Installed In Interim Terminal Building, Kushinagar International Airport I/c Carrying Out Monthly Visit For Servicing And Maintenance Of All Components As Per Oem Standards By Providing Trained Service Engineer With All Tools And Plant And Spares I/c Attending All Breakdown Repairs As & When Required Etc. Complete As Per Instructions Of Engineer In-charge As Required. Note - Total Capacity Of Vrv/vrf Odu Is 400 Hp Of Dakin Make. First Year " "comprehensive Maintenance Contract Of All Vrv/ Vrf System Including All Idu & Odu Of All Capacity, Ahus & Tfas, Referigerant Copper Pipe, Drain Pipe, Inline Fan, Duct/pvc Pipe With Lt Panel For Odu & Idu Including All Installation As Mentioned In Appendix I Installed In Interim Terminal Building, Kushinagar International Airport I/c Carrying Out Monthly Visit For Servicing And Maintenance Of All Components As Per Oem Standards By Providing Trained Service Engineer With All Tools And Plant And Spares I/c Attending All Breakdown Repairs As & When Required Etc. Complete As Per Instructions Of Engineer In-charge As Required. Note - Total Capacity Of Vrv/vrf Odu Is 400 Hp Of Dakin Make. Second Year " "annual Comprehensive Maintenance Of 1.0 Tr, 1.5 Tr And 2.0 Tr Split Type Air Conditioners Of M/s Voltas/carrier/hitachi/lg/haier Etc. Make Installed At Different Locations Of Kushinagar International Airport As Mentioned In Appendix I. Works Include Carrying Out Quarterly Visit For Servicing And Maintenance Of Ac Units Including Attend To Complaints / Faults / Breakdowns And Taking Rectification Action Ensuring Serviceability/satisfactory Working Condition Of The Systems And Also Includes Refrigerant Gas Charging And Repair/replacement Of Required Spares Parts Like Pcbs, Refrigerrant Pipe, Compressors, All Type Of Relays, Motors, Handset Say Remote, Thermostats, Capacitors, Selector Switches, Expansion Valve Etc. And Maintaing Records/ Documentation As Per Engineer In Charge And As Per Special Condition Of The Contract. Note - 1 Job Equal To Acmc Of 1 No Split Ac (1.0 Tr/1.5 /2.0 Tr) For 1 Year. First Year" "annual Comprehensive Maintenance Of 1.0 Tr, 1.5 Tr And 2.0 Tr Split Type Air Conditioners Of M/s Voltas/carrier/hitachi/lg/haier Etc. Make Installed At Different Locations Of Kushinagar International Airport As Mentioned In Appendix I. Works Include Carrying Out Quarterly Visit For Servicing And Maintenance Of Ac Units Including Attend To Complaints / Faults / Breakdowns And Taking Rectification Action Ensuring Serviceability/satisfactory Working Condition Of The Systems And Also Includes Refrigerant Gas Charging And Repair/replacement Of Required Spares Parts Like Pcbs, Refrigerrant Pipe, Compressors, All Type Of Relays, Motors, Handset Say Remote, Thermostats, Capacitors, Selector Switches, Expansion Valve Etc. And Maintaing Records/ Documentation As Per Engineer In Charge And As Per Special Condition Of The Contract. Note - 1 Job Equal To Acmc Of 1 No Split Ac (1.0 Tr/1.5 /2.0 Tr) For 1 Year. Second Year" "annual Comprehensive Maintenance Of 1.5 Tr & 2.0 Tr Window Type Air Conditioners Of M/s Hitachi/o-general Make Installed At Different Locations Of Kushinagar International Airport As Mentioned In Appendix I. Works Include Carrying Out Quarterly Visit For Servicing And Maintenance Of Ac Units Including Attend To Complaints / Faults / Breakdowns And Taking Rectification Action Ensuring Serviceability/satisfactory Working Condition Of The Systems And Also Includes Refrigerant Gas Charging And Repair/replacement Of Required Spares Parts Like Pcbs, Refrigerrant Pipe, Compressors, All Type Of Relays, Motors, Handset Say Remote, Thermostats, Capacitors, Selector Switches, Expansion Valve Etc. And Maintaing Records/ Documentation As Per Engineer In Charge And As Per Special Condition Of The Contract. Note - 1 Job Equal To Acmc Of 1 No. Window Ac (1.5 /2.0 Tr) For 1 Year. First Year" "annual Comprehensive Maintenance Of 1.5 Tr & 2.0 Tr Window Type Air Conditioners Of M/s Hitachi/o-general Make Installed At Different Locations Of Kushinagar International Airport As Mentioned In Appendix I. Works Include Carrying Out Quarterly Visit For Servicing And Maintenance Of Ac Units Including Attend To Complaints / Faults / Breakdowns And Taking Rectification Action Ensuring Serviceability/satisfactory Working Condition Of The Systems And Also Includes Refrigerant Gas Charging And Repair/replacement Of Required Spares Parts Like Pcbs, Refrigerrant Pipe, Compressors, All Type Of Relays, Motors, Handset Say Remote, Thermostats, Capacitors, Selector Switches, Expansion Valve Etc. And Maintaing Records/ Documentation As Per Engineer In Charge And As Per Special Condition Of The Contract. Note - 1 Job Equal To Acmc Of 1 No. Window Ac (1.5 /2.0 Tr) For 1 Year. Second Year" "annual Comprehensive Maintenance Of 4.0 Tr (inverter Type) Tower Air Conditioners Of M/s Blue Star / Haier /carrier Etc Make Installed At Atc Tower Of Kushinagar International Airport As Mentioned In Appendix I. Works Include Carrying Out Quarterly Visit For Servicing And Maintenance Of Ac Units Including Attend To Complaints / Faults / Breakdowns And Taking Rectification Action Ensuring Serviceability/satisfactory Working Condition Of The Systems And Also Includes Refrigerant Gas Charging And Repair/replacement Of Required Spares Parts Like Pcbs, Refrigerrant Pipe, Compressors, All Type Of Relays, Motors, Handset Say Remote, Thermostats, Capacitors, Selector Switches, Expansion Valve Etc. And Maintaing Records/ Documentation As Per Engineer In Charge And As Per Special Condition Of The Contract. Note - 1 Job Equal To Acmc Of 1 No. Tower Ac (4.0 Tr) For 1 Year. Second Year" "annual Comprehensive Maintenance Contract Of Existing Oasis Make Recessed Bi-level Drinking Water Fountain, With Double Ss Bubbler And With Mechanical And Sensor Both Through Oem Only Including Servicing, Repairing, Supply And Replacement Of All Spares I/c Refrigerant Gas, Compressor Etc. As Per The Requirement And Quarterly Preventive Maintenance Visits And Breakdown Visits Through Oem/oem Authorized Service Dealer Only Strictly As Per The Scope Of Work Of Special Condition Of Contract. Note - 1) 1 Job Equal To Acmc Of 1 No. Drinking Water Fountain With Inbuilt Ro For 1 Year. 2) In This Item, The Replacement Of Consumables Like Pf Candle Filter, Block Filter/carbon & Ro Membrane Are Covered Only One Times In A Year. First Year" "annual Comprehensive Maintenance Contract Of Existing Oasis Make Recessed Bi-level Drinking Water Fountain, With Double Ss Bubbler And With Mechanical And Sensor Both Through Oem Only Including Servicing, Repairing, Supply And Replacement Of All Spares I/c Refrigerant Gas, Compressor Etc. As Per The Requirement And Quarterly Preventive Maintenance Visits And Breakdown Visits Through Oem/oem Authorized Service Dealer Only Strictly As Per The Scope Of Work Of Special Condition Of Contract. Note - 1) 1 Job Equal To Acmc Of 1 No. Drinking Water Fountain With Inbuilt Ro For 1 Year. 2) In This Item, The Replacement Of Consumables Like Pf Candle Filter, Block Filter/carbon & Ro Membrane Are Covered Only One Times In A Year. Second Year" Replacement Of Candel 20 Inch /as Per Oem Recommendation And As When Required. (make-oasis) Replacement Of Block 20 Inch /as Per Oem Recommendation And As When Required. (make-oasis) Replacement Of Pf Candel 20 Inch /as Per Oem Recommendation And As When Required. (make-oasis) Replacement Of Gac Filter 20 Inch /as Per Oem Recommendation And As When Required.(make-oasis) "replacement Of Membrane /as Per Oem Recommendation And As When Required (make-oasis) " "annual Comprehensive Maintenance Contract Of 80 Ltrs/hr Water Coolers With Inbuilt Water Purifier (ro Plus Uv) Having Storage Capacity Of Blue Star/cilmatrol Etc.make At Different Locations Of Kushinagar International Airport. Work Include Carrying Out Quarterly Visit For Servicing And Maintenance Of Water Cooler With Ro Units Including Attend To Complaints / Faults / Breakdowns And Taking Rectification Action Ensuring Serviceability/satisfactory Working Condition Of The Systems And Also Includes Refrigerant Gas Charging And Repair/replacement Of Required Spares Parts Like Pcbs, Refrigerrant Pipe, Compressors, All Type Of Relays, Motors, Thermostats, Capacitors, Solenoid Valve Etc. Through Oem Or Authorized Oem Service Dealer And Maintaing Records/ Documentation As Per Engineer Incharge And As Per Special Condition Of The Contract. Note - 1) 1 Job Equal To Acmc Of 1 No. Water Cooler With Inbuilt Ro For 1 Year. 2) In This Item, The Replacement Of Consumables Like Pf Candle Filter, Block Filter/carbon & Ro Membrane Are Covered Only One Times In A Year. First Year" "annual Comprehensive Maintenance Contract Of 80 Ltrs/hr Water Coolers With Inbuilt Water Purifier (ro Plus Uv) Having Storage Capacity Of Blue Star/cilmatrol Etc.make At Different Locations Of Kushinagar International Airport. Work Include Carrying Out Quarterly Visit For Servicing And Maintenance Of Water Cooler With Ro Units Including Attend To Complaints / Faults / Breakdowns And Taking Rectification Action Ensuring Serviceability/satisfactory Working Condition Of The Systems And Also Includes Refrigerant Gas Charging And Repair/replacement Of Required Spares Parts Like Pcbs, Refrigerrant Pipe, Compressors, All Type Of Relays, Motors, Thermostats, Capacitors, Solenoid Valve Etc. Through Oem Or Authorized Oem Service Dealer And Maintaing Records/ Documentation As Per Engineer Incharge And As Per Special Condition Of The Contract. Note - 1) 1 Job Equal To Acmc Of 1 No. Water Cooler With Inbuilt Ro For 1 Year. 2) In This Item, The Replacement Of Consumables Like Pf Candle Filter, Block Filter/carbon & Ro Membrane Are Covered Only One Times In A Year. Second Year" Replacement Of Block/carbon Filter 10 Inch For The Inbuilt Water Purifier Or As Per Oem Recommendation As And When Required. Replacement Of Pf Candel Filter 10 Inch For The Inbuilt Water Purifier Or As Per Oem Recommendation As And When Required. Replacement Of Membrane Filter For The Inbuilt Water Purifier Or As Per Oem Recommendation As And When Required. Dismantling Of Existing Split A.c/window A.c/tower A.c Of Different Rating / Capacity Up To 4 Tr From Existing Site Including Dismantling Of Stand, Stabilizer & Other Associated Accessories Etc, Refilling Existing Holes, Plastering, Finishing The Walls, Shifting Of The Removed Air Conditioning Unit Along With The Accessories Up To Store Room As Per The Direction Of Engineer Incharge And As Per Site Requirement. Installation Testing And Commissioning Of Split A.c/window A.c/tower A.c Of Different Rating /capacity Up To 4 Tr Including Making Holes, Plastering, Refrigerant Gas Charging, Connection With 4 Sq Mm Copper Power Input Cable From Nearest Power Outlet, Testing & Commissioning Etc As Per Site Requirement And As Per The Direction Of The Engineer In Charge. Supply And Installation Of Copper Refrigerant Pipe ( 1/2 Inch Plus 1/4 Inch ) Complete With Fitting Suction Line, Discharge Line With 12 Mm Thick Nitrile Rubber Insulation Between Indoor Unit & Outdoor Unit, Brazing Including Providing Of Clamps, Testing & Commissioning Etc. Complete As Required For 1.0/1.5 Tr Split Ac. Supply And Installation Of Copper Refrigerant Pipe ( 5/8 Inch Plus 3/8 Inch ) Complete With Fitting Suction Line, Discharge Line With 19 Mm Thick Nitrile Rubber Insulation, Brazing Including Providing Of Clamps Etc. Complete As Required For 2.0 Tr Split Ac. Supply And Installation Of Rigid Pvc/flexible Drain Pipe Of 25 Mm Dia With 6mm Heatlon/teflon Insulation Complete With Fittings & Accessories, U Straps Etc. Supplying & Fixing Of Approved Make Electrical Cable 3 Core X 2.5 Sq.mm Suitable For 1.5 / 2.0 Tr Split Airconditioning Unit With Accessories Complete As Required. Providing And Fixing 12 Mm Nitrile Rubber Insulation On The Suction And Discharge Line Of The Existing Split Air Conditioners As Required. Providing And Fixing 19 Mm Nitrile Rubber Insulation On The Suction And Discharge Line Of The Existing 2.0 Tr Split Air Conditioners As Required.

Location
Uttar Pradesh
Due Date
30 Apr, 2025
Amount
Refer Document
Ref. No #34377256 Central Government And Public Sector Live   GeM Tender

Gem Bids For Supplying Of 5 Star Bee Ratings 4 Tr 12000 Kcal Per Hr 3 Phase 400 V 50 Hz Cassette Inverter Type Split Ac Units , Itc Of 4 Tr 5 Star Cassette Type Inverter Ac Unit , Supplying And Charging Of Additional R32 Or R410 Gas For Existing Ac , S And F Of 5 By 8 Inch Dia 20 Gauge Cu Refrigerant Pipe , S And F Of 3 By 8 Inch Dia 20 Gauge Cu Refrigerant Pipe , Pvdg Plumbing Work For Condensate Water Drainage Arrangement Incl Supply Of 25 Mm Dia Isi Marked Upvc Pipe , Pvdg Plumbing Work For Condensate Water Drainage Arrangement Incl Supply Of 40 Mm Dia Isi Marked Upvc Pipe , Pvdg Ms Structure Made Out Of Ms Angle Flat And C Channel For Condenser Stand And Tray , Point Wiring _group C , Wiring For Circuit Or Submain Wiring With The 2 X 1 Point 5 Sq Mm Plus 1 X 1 Point 5 Sq Mm Earth Wire , Wiring For Circuit Or Submain Wiring With The 2 X 2 Point 5 Sq Mm Plus 1 X 2 Point 5 Sq Mm Earth Wire , Wiring For Circuit Or Submain Wiring With The 4 X 2 Point 5 Sq Mm Plus 2 X 2 Point 5 Sq Mm Earth Wire , S And F 20 Mm Medium Class Pvc Conduit , S And F 25 Mm Medium Class Pvc Conduit , S And D Of 1 X 1 Point 5 Sq Mm Frls Pvc Insulated Cu Conductor , S And D Of 2 X 1 Point 5 Sq Mm Frls Pvc Insulated Cu Conductor , S And D Of 3 X 1 Point 5 Sq Mm Frls Pvc Insulated Cu Conductor , S And D Of 4 X 1 Point 5 Sq Mm Frls Pvc Insulated Cu Conductor , S And D Of 5 X 1 Point 5 Sq Mm Frls Pvc Insulated Cu Conductor , S And D Of 6 X 1 Point 5 Sq Mm Frls Pvc Insulated Cu Conductor , P And F 16 Strands Of Each 0 Point 20 Mm Dia Or 0 Point 5 Sq Mm Twin Flat Flexible Frls Pvc Insulated Cu Cable In Pvc Sleeve , S And F Of 5 Or 6 Amp Modular Switch , S And F Of 15 Or 16 Amp Modular Switch , S And F Of 3 Pin 5 Or 6 Amp Modular Socket Outlet , S And F Of 6 Pin 15 Or 16 Amp Modular Socket Outlet , S And F Of 1 Or 2 Module Or 75mm X 75mm Size Modules Gi Box With Base And Cover Plate , S And F Of 4 Module Or 125mm X 75mm Size Modules Gi Box With Base And Cover Plate , S And F Of 6 Module Or 200mm X 75mm Size Or Modules Gi Box With Base And Cover Plate , S And F Of 8 Module Or 125mm X 125mm Size Modules Gi Box With Base And Cover Plate , S And F Of Gi Box With Modular Plate And Cover Including P And F Modular 3 Pin 5 Or 6 Amps Socket Outlet And 5or 6 Amps Switch , S And F Of Gi Box With Modular Plate And Cover Including P And F Modular 6 Pin 5 Or 6 And 15 Or 16 Amps Socket Outlet And 15 Or 16 Amps Switch , S And F 36 Watt Led Light Fitting Having Fully Diffused Recess Mounted 1ft X 4ft Led Luminaire With High Transmittive Diffuser , Sitc Of Single Phase 400 Mm Sweep High Speed Wall Mounted Bldc Motor Fan , Sitc Of Passive Infrared Technology Based Occupancy Sensor , Sitc Of 10 Kva On Line Ups Having Minimum 30 Minutes Backup With 1ph_1ph In_out , S And L Of 2 Core 16 Sq Mm Cu Conductor Armoured Cable , S And L Of 5 Core 4 Sq Mm Cu Conductor Armoured Cable , S And L Of 4 Core 2 Point 5 Sq Mm Cu Conductor Armoured Cable , S And L Of 3 Core 1 Point 5 Sq Mm Cu Conductor Unarmoured Cable , S And L Of 5 Core 1 Point 5 Sq Mm Cu Conductor Unarmoured Cable , S And L Of 4 Core 50 Sq Mm Al Conductor Armoured Cable , Supplying And Installing 150 Mm X 50 Mm X 1 Point 6 Mm Thick Perforated Prepainted Ms Cable Trays , P And F 6 Swg Dia Gi Wire Along With Existing Surface Or Recessed Conduit Or Submain Wiring Or Cable , P And F 4 Mm Dia Cu Bare Wire On Surface Or In Recess For Loop Earthing , S And F Of 4 Way 4 Plus 12 Ways Double Door Vertical Type 415v Tpn Sheet Steel Mcb Db , S And F Of 8 Way 4 Plus 24 Ways Double Door Vertical Type 415v Tpn Sheet Steel Mcb Db , S And F Of 2 Plus 12 Double Door 240 V Spn Sheet Steel Mcb Db , P And F Of 100 Amp Rating 30 Ka Breaking Capacity And 4 Pole Mccb , S And F Of Sp 5 Amps To 32 Amps Rating 240 V C Curve Mcb , S And F Of Spn 5 Amps To 32 Amps Rating 240 V C Curve Mcb , S And F Of Tp 5 Amps To 32 Amps Rating 415 V C Curve Mcb , S And F Of Tpn 5 Amps To 32 Amps Rating 415 V C Curve Mcb , Sitc Of A 80 Ltr Water Cooler Having 60 Ltr Cooling Capacity Per Hr With Purifier Ro Plus Uv , P And F Of Anti Microbial Portable Room Air Purifier

Location
Maharashtra
Due Date
02 May, 2025
Amount
Refer Document
Ref. No #34382227 Central Government/Public Sector Live   GeM Tender

Gem Bids For 1 Cacw Cooler Unit For Id Fan Motor 5200kw 11kv

Location
Tamil Nadu
Due Date
06 May, 2025
Amount
Refer Document