Tender Details Email Tender
Reference # :
20528361
Description :
Tenders for Providing And Fixing Of Material 4 Bolted Type Pg Clamp Suitable For Moose To Moose Conductor Complete With Hdg Nut Bolt & Washer As Per Technical Specification. Corona Ring For 400 Kv Bpi Having 1 No Battom Ring 2 Ips Pipe Of 40Mm Dia With 3 No 200X35x80 Mm Aluminum Support Top Circular Plate Size 165X12 Mm Having 20 Mm Dia Hole At 900 Spacing As Per Sample. Supply Bmk With Canopy For Outdoor Installation Of Size 1500X800x300 With Ms Sheet Thickness 14 Swg Dully Powder Coated Of Good Quality Bmk Should Be Fixed 160 Nos Connector Of 16 Amp On Channel Gland Plate With 20 Nos Cable Gland Of Different Size Fron 10 To 02 Core Cable Provision Of Heater And Indoor Lighting Fitting 16 W Cfl Bmk With Two Side Door Front & Back Bmk Shall Be Weather, Dust & Vermin Proof With Proper Locking Arrangement With Base As Per Technical Specification. Supply Of Power Receptacles With Knopy For Outdoor Installation Rating 415 V, 400 Amp. 3 Phase And Neutral Of Size 1550X800x500 Mm With Ms Sheet Thickness 14 Swg Duly Powder Coated Of Good Quality. The Receptacles Shell Be Provided Incorporating A Manually Operated Tpn On Load Change Over Selector Switch Of Havell’S/C&S/Standard Make Rated For 400 Amp-1 No. With 08 Nos. Aluminum Insulated Bus Bar Suitable For 3.5 X 400 Sq.Mm Pvc Armoured Cables-1 No. On Incoming Side And On Outgoing Side 04 Nos. Aluminum Insulated Bus Bar With Section Window/Door & 1 No. Side Window/Door Gland Plate With 02 Nos. Cable Gland Suitable For 3.5 X 400 Sq.Mm Pvc Armoured Cable, Provision Of Visual Indication Of Incoming Supply & Indoor Light Fitting 16 W Cfl. Power Receptacles Shall Be Weather, Dust And Vermin Proof With Proper Locking Arrangement With Base For Centrifuging Work Of Transformer As Per Technical Specification. Supply Of Power Supply Cubical Reactor Isolator & Breaker With Knopy For Outdoor Installation Rating 415 A 200 Amp 3 Phase Of Size 1800X600x500 Mm With Ms Sheet 14 Swg Duly Powder Incorporating A Manually Operated Tpn On Load Change Over Selector Switch Of Havell’S/C&S/Standard Make Rated For 200 Amp-1 No. With 08 Nos. Aluminum Insulated Bus Bar Suitable For 3.5 X 70 Sq.Mm Pvc Armoured Cables -02 Nos. On Incoming Side And On Outgoing Side 32 Amp. 3 Pole Mcb-04 Nos. 16 Amp. 3 Pole Mcb-04 Nos. 6 Amp. Single Pole Mcb -04 Nos. Of Havell’S /Legrand Make. Power Supply Cubical With Double Door 01 No. Fr. Door And 02 Nos. Inside Door One For Bus Bar Section For Incoming Supply & Second For Mcb Section For Outgoing Supply. Provision Of Gland Plate With 02 Nos. Cable Glands Suitable For 3X70/95 Sq. Mm Pvc Armoured Cable. Complete Proper Wiring From 200 Amp. Tpn To Mcb With Copper Wire & Lugs Along With 40 Nos. Tb Suitable Size. Provision Of Visual Indication Of Incoming Supply & Indoor Light Fitting 16 W Cfl Power Receptacles Shall Be Weather, Dust And Vermin Proof With Proper Locking Arrangement With Base As Per Technical Specification. Bus Post Insulator Clamp Made Of Lm-6 Aluminium Alloy For Post Insulator Suitable For Twin Moose Conductor With Galvanized Nut & Bolt And Washer As Per Sample. Spacer Made Of Lm-6 Aluminium Alloy 02 Bolted Type Size 16 Mm. Complete With Nut & Bolt And Washer Etc. Having 450 Mm. Between Conductor And Width 38 Mm. For Moose Conductor. Part-Ii Work Safe Loading At 400 Kv S/S Gorakhpur And Safe Unloading At 400 Kv S/S Panki Of Following Material On The Private Carrier With The Help Of Manual Labour And Crane. 400 Kv Pentagraph Isolators Including All Accessories Like Mom Boxes, Rotary Insulator, Support Insulator Etc. 400 Kv Standard Line Isolator With All Accessories I.E. Mom Boxes, Rotary Insulator, Support Insulator Etc. Safe Carriage Of Following Material On The Private Carrier From 400 Kv S/S Gorakhpur To 400 Kv S/S Panki Distance Approx. 400 Km. 400 Kv Pentagraph Isolator 02 Nos. And 400 Kv Line Isolator 01 No. With All Accessories Of Isolator. Erection Of Following 400 Kv Reactor Bay Equipments After Proper Alingement With The Help Of Men, T & P, Crane, Rope, Steel Celling Etc. Required During Complition Of Work And All Other Associated Works In Strict Supervision Of Engineer Incharge As Per Details Below. 420 Kv 3150 Amp, 40 Ka Sf-6 Circuit Breaker With Structure & Control Cubical. 420 Kv, 5-Core, Current Transformer With Ratio 3000/2000/500/1-1-1A With 120% Extended Current Rating. 420 Kv Bus Post Insulator 420 Kv, 2000Amp, 40 Ka Pantograph Isolator With 1 E/S 420 Kv, 2000Amp, 40 Ka Pantograph Isolator Without E/S 420 Kv 3150A 40Ka Centre Post Rotating Insulator Standard Isolator With 2 E/S 400 Kv Bay Marshalling Kiosk. 400 Kv Ct Junction Box. Erection Of Ac Power Cubical 400 Kv Reactor/ Breaker. Erection Of Duplex Type Control & Relay Panel. Steel Structure Erp Pipe Type Structure For Equipment. Interconnection Of Bay By Twin Acsr Moose Conductor. The Work Includes Shifting, Cutting, Clamping Etc. For Completion Of Work Satisfactorily. Dismantaling Of Following Equipments/Panel. The Work Opening Of Jumpers, Cutting Of Earthing, Opening Of Nut And Bolt And Control Cable Etc. For Proper Work. The Work Also Includes Shifting Of Material From Site To Store. 400 Kv Bpi With Structure. Bus Reactor Electromechanical Relay Panel Old. Bus Reactor Control Panel Dummy/Spare C&R Panel. Laying Of 3.5Cx250 Mm2 Aluminium Power Cable Below 500 Mm. Ground Level Including Excavation Of Trench, Laying Of Cable, First Class Brick On Its 75 Mm. Edge Along With Cable On Both Side, Filling The Same With River Sand And Then Putting Bricks On 115 Mm. Side Over The Trench And Then Filling Earth Including Cost Of Bricks, Sand Etc. All Other Associated Work To Complete The Job Satisfactorily. 3.5Cx250 Mm² 3.5Cx250 Mm² Termination Of Cable Laying Of Armoured Copper Control Cable Pvc 1.1 Kv Grade Of Different Sizes Control Relay Pannel And Various Equipment Marshalling Box, Jb In Switch Yard Making Hole Of Proper Size Providing Ferrule And Then Wiring As Per Drawing. Note :- Gland Will Be Provided By The Contractor At His Own Cost 2C X 2.5 Sq.Mm 5C X 2.5 Sq.Mm 10C X 2.5 Sq.Mm 14C X 2.5 Sq.Mm Termination Of Above Laid Controle Cabels As Per Schematic Drawing & Cable Schedule Provided By Contractor Including Proper Ferruling And Then Wiring Both Ends Termination Of Control Cable Will Be Considered As 01 No Note :- Ferrule, Lug And Tie Will Be Provided By The Contractor At His Own Cost Excavation Of Earth, Cutting Bending, Laying, Welding And Painting Inside Ground 700Mm Below & Ground Of 75X100 Mm/50X6mm Ms Flat For Earthing Of Aux. Structure & Equipments In 400 Kv Equipments Including Earthing With Main Earth Mat And With Object To Be Earthed Back Filling Of Soil And All Other Associated Works To Complete The Work. Ms Flat 75X10mm Ms Flat 50X6mm Ms Flat 25X6mm Fabrication Of Aux. Earth Mat Of Square Shapped Of Size 1500X1500mm Making A Mesh Of 06 Nos Bar Horizontally And 06 Nos. Bar Vertically. Bar Spacing At 300Mm Apart Both Vertical And Horizontal As Per Drawing By Cutting & Welding Then Laying And Placing The Mat Below At 700Mm Depth. The Work Also Include Connection The Aux. Earth Mat With Main Earth Mat At X & Y Bars With 40Mm Ms Round Along With All Associated Works Round Bar Provided By Department Painting Of Ms Flat Cleaning By Surface 1St Coat Of Red Oxide And 2 Coat Of Bus Green Paint. Ms Flat 75X10 Mm Ms Flat 50X6 Mm Ms Flat 25X6 Mm Dismantling Of 3X16.67 Mvar Reactor And Shifting, Erection Of 125 Mvar Reactor Dismantling Of Mulsifire Pipe Line Of Mulsifire Air And Water Of 3X16.67 Mvar Bus Reactor By Cutting And Opening Of Pipe Line And Earthing Etc And Shifting Upon Store. Opening Of Jumper, Electrical Connection And Cutting Of Earthing Of Reactor. Dismantling Of All Accessories Of Old 3X16.67 Mvar Bus Reactor Draining Out Oil From Radiator And Main Tank Upto Required Level In Oil Drums Removels Of All Rediators. Conservator. Oil Pipe Line. Hv Bushing. Turret Etc. With Proper Gasket And Blanking Plates Including Stacking Of Radiators. Shifting Of Main Tank Of 3X16.67 Mvar Bus Reactor Plinth To Storage Platefrom By Dragging Main Tank Upto 20 Mtrs. Additional Shifiting Of Main Tank @5 Mtrs. Per Job Approx. 200 Mtrs Each Shifting Of All Dismantled Part Of 3X16.67 Mvar Reactor Accessories As Radiator, Conservator Tank, Different Size Of Pipe And Other Accessories With The All Cost Of Hydra/ Craine Etc. Shifting Main Tank Of 125 Mvar Bus Reactor From Unloading Place To Existing Plinth By Dragging Up To A Distance About 125 Meter. Up To 20 Meters Additional Shifiting 5 Meters Each Providing Dry Air Plant Minimum Capacity-500 C Dew Point With Dew Meter And All Accessories Suitable For Injecting Dry Air In Main Tank Of Reactor During Installation And Commissioning Of 125 Mvar Bus Reactor Complete Erection Of 125 Mvar Reactor Including Radiator, Conservator Tank, A-Frame, Header, Hv/Lv Bushing And Its Turret, Connecting All Pipe Lines, Drives Mechanism, Cooling Fans, Oil Pumps Etc. Complete Evaculation Of 125 Mvar 400Kv Bus Reactor Main Tank And Filling Of Dry Air/ Dry Nitrogen Of Due. Point -500 C Or Better In Vaccum Upto Pressure Of 0.25 Kg/Cm2 And The Again Avacuation The Reactor Tank After Required Time Interval Approx 12/24 Hrs Or As Per Direction Of Engineer Using Vacuum Plant. The Work Shall Including Connecting Pipe Machine As Required Measuring Dew Points Valve Of Nitrogen After Every Cycle Till The Required Value. Filling The Transformer Oil In Oil Tanker Including Shifting Of Oil Drums From Store To Work Site & Thereafter Shifting The Empty Drums From Work Site To Store For Its Proper & Safe Stacking. Applying Vacuum To 125 Mvar Reactor Main Tank Up To 760 Mm Of Hg For 24 Hrs With Adequate Capacity Of Vacuum Pump. Centrifuging Of Fresh Transformer Oil In Oil Tanker 50 Kl Oil Tanker With 12 Kl Centrifuging Machine Of 125 Mvar Bus Reactor & Recording All Parameters Hourly & Then Its Filling In Main Tank And Radiator Up To Required Level & Thereafter Its Centrifuging In Main Tank After Opening All The Valves Of Radiator, Conservator Tank Till The Satisfactorily Results Obtained. Earthing Of Reactor, Marshalling Box, A-Frame Etc With 75X10 Mm Ms Flat Including Its Straightening, Cutting, Bending And Laying 700 Mm Below Inside The Ground And Ms Flat Of Size 75X10 Mm For Earthing Of Reactor, Mb, A Frame Including Welding With Main Earthmat And Object To Be Earthed. Excavation Of Trenches Its Back Filling Ramming Etc. And All Other Work Required To Complete Job Satisfactorily. Delta Earthing Of Neutral Of 125 Mvar Reactor Consisting Of 3 Nos 3 Meter Long Electrodes Of Ms Round Bar Of 36/32 Mm Dia Its Placing Inside The Ground And Connection All 3 Electrodes With 75X10mm Ms Flat & Connection The Same With Main Earthmat At 2 Places As Required Ms Round Bar & Ms Flat Shall Be Provided By The Department. Laying, Dressing And Binding Of Cable Including Fixing Of Cable Tray Support Structure And Termination Of Cable, Proper Glanding Of Cable, Marking The Top And Its Ferruling As Per Schedule And Inter Connection Including Shifting Of New Cable As Per Requirement Upt To The Marshallling Box. Painting Of Earht Strip Of Size 75X10 Mm Above The Ground Level By One Coat Of Red Oxide & Two Coats Of Bus Green Paint Of Asian/Berger Including Cost Of All Labour Materials Required To Complete The Job Satisfactorily. Laying And Fixing Of New Pipe Line Of Mulsifire System Along With New Deluge Valve 150 Nb Remodification Of Emulsifire Pipe Line With Supply & Installation Of High Velocity Automatic Water Spraying System For 125Mvar Reactor Including Laying Of Fire Detection/Water Pipe Line, Valves, Quartzoid Bulb, Hvws Nozzles Along With All Material Completes As Per Details. Supply & Installation Testing Commissioning Of Quick Opening Flood, Deluge Valve Of Hd Of 150 Nb As Per Max Working Pressure 10 Kg/Cm2 A Per Specification Hd/Mather Platt/Equivalent Supply & Installation & Commissioning Of Gate Valve Sluice Valve/ Butterfly Valve As Per Is Specification Is Code: 14846 Of Zoloto/Kartar/Sir Make 150 Nb Supply & Installation & Testing Commissioning Of Y Type Strainer Kartar/Sir/Kalpana/Agro Make Of Dia Max. Working Pressure 7 Kg/Cm2. 150Mm Supply & Laying Of Different Sizes Of Pipe B Class For Fire Water Pipe Line/Support As Per Is Specification Is Code-1239 As Per Drawing Enclosed Complete With Elbow Tee, Socket Reducer Etc. With Anti Corrosive Treatment With Detail As Below. 150 Nb 100 Nb 80 Nb Supply And Laying Of Different Size Of Gi Pipe B Class For Fire Detection/ Water Pipe Line As Per Specification Is Code-1239 As Per Drawing Enclosed Complete With Elbow, Tee, Socket, Reducer. 65 Nb 50 Nb 40 Nb 25 Nb Supply & Installation Of Flanges As Per Is-1538 Of Different Sizes As Per Drawing Work Include Porper Butt Welding With Pipe & Propre Packing And Coupling With Nut & Bolt 1 Set 2 Nos Flanges 80 Nb 65 Nb 50 Nb 40 Nb 25 Nb Supply & Installation & Commissioning Of High Velocity Water Spray Nozzle Flow Capacity 3.5 Kg/Cm2 Spraying Core Angle 900. Supply & Installation & Commissioning Of Quartzoid Buld Detectors Qbd Operate At 790C Sensing At Rated Temp For Actuation Of The Element 10-12 Sec. Supply & Installation & Testing Commissioning Of Fixed Differential Switch Danfoss/Indofoss Make Type Pressure Switch Range 1-10 Kg/Cm2. Pressure Gauge As Per Is Specification Is Code 3624, Accuracy 1/+5%. For Construction Of 400 Kv 125 Mvar Reactor Bay At 400 Kv Sub-Station Panki
Tender # :
ET-167/ETC-I(K)/2020-21
Key Values
Value :
4,869,450 (48.69 Lacs )
EMD :
49,000 (49.0 Thousand )
Doc. Cost :
5,782 (5.7 Thousand )
Key Dates
Due date :
15 Apr, 2021
Location
Location :
Uttar Pradesh
Get More Info